SMC Corporation of America
Elite Part Number Search
Search Results "11-MXJ4-10-M9PSAPC"

Specification: 11 (Clean Series, Vacuum Suction Type), Bearing Type: M (Slide Bearing), Bore Size: 15mm, Port Type: M5x0.8: 6-20mm Bore; Rc: 25-32mm Bore, Stroke: 10mm, Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal

Specification: 11 (Clean Series, Vacuum Suction Type), Bearing Type: M (Slide Bearing), Bore Size: 6mm, Port Type: M5x0.8: 6-20mm Bore; Rc: 25-32mm Bore, Stroke: 10mm, Auto Switch: Y7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)

Specification: 11 (Clean Series, Vacuum Suction Type), Bearing Type: L (Ball Bushing Bearing), Bore Size: 6mm, Port Type: M5x0.8: 6-20mm Bore; Rc: 25-32mm Bore, Stroke: 10mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Specification: 11 (Clean Series, Vacuum Suction Type), Bearing Type: L (Ball Bushing Bearing), Bore Size: 32mm, Port Type: TN (NPT: 25 & 32mm Bore), Stroke: 10mm, Auto Switch: Y7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Specification: 11 (Clean Series, Vacuum Suction Type), Bearing Type: L (Ball Bushing Bearing), Bore Size: 15mm, Port Type: M5x0.8: 6-20mm Bore; Rc: 25-32mm Bore, Stroke: 10mm, Auto Switch: Y59A--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Specification: 11 (Clean Type, Vacuum Suction), Bore Size: Ø10, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: W/Magnet and Rail, Auto Switch: M9N (Solid State, Gen. Purpose, 3 Wire NPN, Horizontal), Lead Wire: M (1m)

Specification: 11 (Clean Type, Vacuum Suction), Bore Size: Ø10, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: W/Magnet and Rail, Auto Switch: M9PW (Solid State, 2-color Indication, 3 Wire PNP, Horizontal), Lead Wire: M (1m)

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (vacuum type), Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Specification: Clean Series (vacuum type), Port thread type:

Specification: Clean Type, Vacuum Suction, Bore Size: Ø10, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: W/Magnet and Rail, Auto Switch: Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 1m, Number: -

Specification: Clean Type, Vacuum Suction, Bore Size: Ø10, Stroke: 10mm, Adjuster: Rubber Stopper, Magnet: W/Magnet and Rail, Auto Switch: Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire: 1m, Number: -

Common exhaust Individual exhaust 10 VT315-OMH0002-D TROUBLE SHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

If this occurs, stabilize the ambient temperature and fluid temperature properly. -11- 6.

Spare Parts List 10 9. Drawings 11 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

If this occurs, stabilize the ambient temperature and fluid temperature properly. -11- 6.

In the case of diodes, the residual voltage is approximately 1V. 10. Extended periods of continuous energization. If a valve will be continuously energized for an extended period of time, the temperature of the valve will increase due to the heat generated by the coil assembly. This will likely adversely affect the performance of the valve and any nearby peripheral equipment.

Bracket, gauge and switch assembly (optional) 10 6. Panel mounting 11 7. Troubleshooting 12 8. Dimensions 13 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Bracket, gauge and switch assembly (optional) 10 6. Panel mounting 11 7. Troubleshooting 12 8. Dimensions 13 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Clean specifications include 10- (relief type), 11- (vacuum suction type), and 12- (relief type with specially treated sliding parts) , Other specifications include copper, fluorine and silicon-free + low partical generation (21- and 22-), Types 10-, 11- and 22- are available with ball bushing or slide bearings, Types 12- and 21- have ball bushing bearings, Piston Rod Assembly, GUIDED CYLINDER