Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Temperature Sensor: Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to

Further improvements include the addition of 2 screens, incorporating 3-color numerical displays which can also be rotated in both clockwise and counter-clockwise directions, thereby offering even better display visibility during operation. 

Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X143 (Piping Material

Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: Piping Material Brass

, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: Analog 4 to 20mA 2

options with a wide range of accessories.Modular air filter , Prevents contamination , Lighter weight than old style modular AF , Thickness reduction of resin case provides increased capacity (approx. 1.3 times more). , Improved water separation efficiency extends the service life of filter elements , Rc, NPT or G(PF) type threads, FILTER, MODULAR, 3/4 G, AIRLINE EQUIPMENT, AF MASS PRO, GA

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to 10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START, VALVE, AV SOFT START UP BODY PORT, GA, AV BODY PORT 3/8 NPT, 1.26765 lb

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to 10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START, VALVE, AV SOFT START UP BODY PORT, GA, AV BODY PORT 3/8 NPT, 1.64266 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, MALE CONNECTOR, CONNECTORS, KQ2 FITTING, GA, KQ2 1/4, .02053 lb

Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FITTING, DIFF DIAM STRAIG *LQA, CONNECTORS, KQ2 FITTING, GA, KQ2 1/4, .03139 lb