Finger positions can be selected (Standard type/MHZ2) Lateral mounting Vertical mounting Axial mounting Standard type (MHQG2 compatible width) Narrow type (MHQ2 compatible width) Using tapped holes Using end boss Using tapped holes Using through holes Body options Finger options Basic type End boss type Side ported Side ported With One-touch fitting for coaxial tube Side tapped Basic type

LC1-1H2 Item 100/110V AC 10%, 50/60Hz (100V AC, 50/60Hz for LC1-1HV1) 200/220V AC 10%, 50/60Hz (200V AC 10% for LC1-1H32) (200V AC, 50/60Hz for LC1-1HV2) Power supply Leakage current 5mA or less Dimensions 80 x 120 x 244mm Weight 2.2kg Actuator control Item Model LC1-1H2H LC1-1H3H LC1-1H2V LC1-1H3V Compatible actuator model LTF6ELTF8FLTF6E-K LTF6E-K Motor capacity 200W 100W 200W 100W 5 to 40C

AL Turbine Oil Class 1 (With no additives), ISO VG32 ISO viscosity grade Viscosity classification cSt (40C) ISO viscosity grade 32 Viscosity classification cSt (40C) 32 Idemitsu Kosan Co.,Ltd. Kygnus Oil Co. Turbine oil 32 Turbine oil P-32 Composite effective area (mm2) Model Kyushu Oil Co. Stork turbine 32 Turbine oil 32, Mitsubishi Turbine 32 Nippon Mitsubishi Oil Corp.

Min. bending radius (mm) Note) 4 Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) Material Polyurethane Color Black(B), White(W), Red(R), Blue(BU), Yellow(Y), Green(G), Clear(C) Burst Pressure Characteristic Curve and Operating Pressure Note) At a temperature of 20C bend the tubing into a U shape.

Operating Pressure Air 145psi (1.0MPa) Size At 75F (24C) At 200F (93C) 3/8 1/4 1/2 5/32 5/8 3/4 1400psi 1200psi 950psi 1200psi 900psi 800psi Proof Pressure 450psi (3.1MPa) Recommended Fluid and Ambient Temperature* -40F to 140F (-40C to 60C) 7 Ncm/min. or less Leak Rate at -40F (-40C) Thread Portion Nut ANSI/ASME B1.20.1, 1983, R1992 Thread JIS B 0208 (Unified fine thread), ISO 263 Thread

Servo motor (24 VDC) 77F = 25C, 104F = 40C Ambient temperature: 25C or less Ambient temperature: 40C LEY16Am Pushing force [%] Duty ratio [%] Continuous pushing time [min.]

Temperature range which can be set with the Thermo-chiller L : 20C to 40C (L2 (clear water, deionized water specification) can be set 10C to 40C.)) H : 20C to 90C W: 20C to 90C (Select W only when the temperature ranges of L or H are not applicable. HRZ010-W2S (clear water, deionized water specification) can be set 10C to 60C.

0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

The specified ambient temperature range is 0 to 40C.

Evaluation criteria for ozone resistance SMC's evaluation criteria for ozone resistance in its products can be defined as follows: Products meeting a 5-year (or 43,800 hours) resistance rating (or equivalent) under working conditions that include 40C ambient and fluid temperatures and an ozone concentration of 0.03ppm in 0.5MPa compressed air.

Store away from direct sunlight in a location at no more than 40C. 1981-2000 Reprint May 2000 6

Valve Temperature Range: Standard Valves 0F ( 18C) to 104F (40C) ambient; 0F ( 18C) to 150F (65C) media. Optional Valves can tolerate much higher or much lower ambient and media temperatures.

Valve Temperature Range: Standard Valves 0F ( 18C) to 104F (40C) ambient; 0F ( 18C) to 150F (65C) media. Optional Valves can tolerate much higher or much lower ambient and media temperatures.

Parallel output Stop points Compatible encoder Serial communication Memory LED indicator 7-segment LED display Note 3) Lock control Cable length [m] Cooling system Operating temperature range Operating humidity range [%RH] Storage temperature range Storage humidity range [%RH] Insulation resistance [M] Weight I/O cable: 5 or less Actuator cable: 20 or less Natural air cooling 32 to 104F (0 to 40C

Front matter 5 (4) Test method By attaching the equipment for testing with the test circuit shown in Fig. (3) and running water at 5 to 40C, measure the flow rate with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that the Reynolds number does not go below a range of 4 x 104.

Applicable Fluids Standard Option (1) Water (Standard, Up to 40C) Air (Standard, dry), Turbine oil Vacuum (Up to 1 Torr) Carbon dioxide (CO2), Nitrogen gas(N2) Freon11, 113, 114 Vacuum (Up to 103 Torr) (V, M) Non-leak (105 atm cc/sec or less) (V, M) Symbol N.C.

Valve open Valve open IDFS6E to 11E IDUS3E to 6E Use the air dryer with an ambient temperature lower than 40C. When installing air piping at the air inlet/outlet of air dryer, the IN/OUT port's fitting of air dryer must be held firmly in place with a wrench. Variation of operating conditions may cause condensate to form on the surface of the outlet piping.

Model LMU100 LMU200 ALF ALT Inlet air pressure Oil tank set pressure range Oil Dynamic viscosity of oil (40C) 0.1 to 1.0 MPa 0.05 to 0.2 MPa Turbine oil, Non-water soluble cutting oil (JIS, N1 type) 2 to 200 mm2/s Total capacity: 3000 Effective capacity: 2500 5 to 50C 100 VAC 50/60Hz, 200 VAC 50/60Hz, 24 VDC ALD ALB Oil tank capacity (cm3) Ambient and fluid temperature Solenoid valve voltage

Fluid Standard specifications Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x 102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x 10-1 Pa) (V, M) Non-leak (106 Pam3/s or less) (V, M) JIS Symbol A C.O.

/h) 11 SCFM 16 SCFM 26 SCFM 43 SCFM 62 SCFM 80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110 m 3/h) (147 m 3/h) 100psig (0.7MPa) 100 F (37.8C) 100 F (37.8C) 115V 60Hz 41-122 F (5-50C) 22psig (0.15MPa) 150psig (1.0MPa) () 36-104 F (2-40C