Length per roll (m) Tubing material Symbol T Material Nylon Symbol TI Material Nylon Symbol 20 20 m (Standard) Length Metric size Inch size TS Soft nylon TU Polyurethane TIS Soft nylon TIU Polyurethane Color Symbol B Color Black Symbol B Color Black Nylon Soft nylon Inch size Tubing size W White BU Blue W White Metric size Size Size R Red Symbol Symbol 0425 O.D. 4 6 8 8 10 10 A05 Size O.D
Symbol S Z 5 19.5 10 28.5 15 37.5 20 46.5 5 40 10 49 15 58 20 67 Bore size (mm) Stroke 4 6-2-5
W/ surge voltage suppressor is available for grommet type only.
Cylinder ports should be NAMUR hole pattern. 100/200 V (50/60 Hz) 24 V 15 to +10% of rated voltage Class B or equivalent 5.0 VA/60 Hz, 5.6 VA/50 Hz 2.3 VA (1.5 W)/60 Hz, 3.4 VA (2.1 W) 9/50 Hz 1.8 W Grommet, Grommet terminal, Conduit terminal, DIN terminal Note 1) Use dry-air at low temperature. Note 2) Use turbine oil Class1 (ISO VG32), if lubricated.
Stations: 01 (1 Station), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
ZS-20-A 16 NPN open collector 2 output w/o analog output, 3 turns adjustment With lead wireZS-20-5A17 NPN open collector 2 output w/o analog output, 200 degrees adjustment Note) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length 18 NPN open collector 1 output w/analog output, 3 turns adjustment 0.6 m Nil Ex.) ZSE1-01-15CN1 pc.
ZS-20-A NPN open collector 2 output w/o analog output, 3 turns adjustment 16 With lead wireZS-20-5ANPN open collector 2 output w/o analog output, 200 degrees adjustment 17 Note) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length NPN open collector 1 output w/analog output, 3 turns adjustment 18 0.6 m Nil Ex.) ZSE1-01-15CN1 pc. ZS-20-5A-501 pc.
ZS-20-A NPN open collector 2 output w/o analog output, 3 turns adjustment 16 With lead wireZS-20-5ANPN open collector 2 output w/o analog output, 200 degrees adjustment 17 Note) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length NPN open collector 1 output w/analog output, 3 turns adjustment 18 0.6 m Nil Ex.) ZSE1-01-15CN1 pc. ZS-20-5A-501 pc.
w t t q q IN OUT IN OUT e y y e r u r u Drain Drain Component Parts No.
w t t q q IN OUT IN OUT e y y e r u r u Drain Drain Component Parts No.
Drip failure can cause damage to the components that need lubrication. 14-2-62 Lubricator Series AL10 to 60 Construction AL10 AL20 JIS Symbol w w e q q t IN OUT IN OUT F.R.L. y y AV r u u AU AF AR AL30/40 AL50/60 IR w w q t VEX q e e t AMR IN OUT OUT IN ITV y r IC i r u VBA VE VY1 y G u PPA AL Component Parts Description Material Note No.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.