(See Table 4 on page 15.) 11 - Table 3 Auto Switch Mounting Bracket / Part No. 12 - 17.5 17.5 17.5 17.5 17.5 17.5 13 - 14 - Table 4 Minimum Stroke for Auto Switch Mounting 15 - Table 5 Operating Range 16 - Auto Switch Connection and Example 17 - 3. Maintenance Caution For the CJ2-*Z series, the cover and cylinder tube are joined by rolling crimping, and cannot be disassembled.
9 Rod seal NBR Basic (B) CM2QB Bore size Stroke (mm) Stroke range 1 to 300 1 to 300 1 to 300 1 to 300 S 65 65 67 91 N 15 15 15 21.5 Bore A 18 22 22 24 B2 26 32 32 41 D 8 10 12 14 H2 8 8 8 10 I 28 33.5 37.5 46.5 ZZ 119 123 125 157 NA 24 30 34.5 42.5 AL 15.5 19.5 19.5 21 E F 13 13 13 16 K 5 5.5 5.5 7 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 B1 13 17 17 22 G 8 8 8 11 MM M8 X 1.25 P 1/8 1/8 1
It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8
H/DL L/LL Soft polyurethane tubing 2 cores X169 (Roll) 3 cores X170 (Roll) 4 cores X171 (Roll) 5 cores X172 (Roll) Fluid Air Max. operating pressure MPa KC Number of cores KK Inner sleeve 20C 0.6 40C 0.6 60C 0.4 Applicable fittings One-touch fitting Note 2), Insert fitting, Miniature fitting (Hose nipple type) Min. bending radius Note 1) (mm) 8 15 15 22 29 Operating temperature 20 to +60C
Dimension AVL2000 to AVL5000 Soft start up valve with lock out AVL2000/3000/4000/5000 (mm) Port size A B Model C D E F G H Lockable soft start valve. Gradual increase of supply pressure and rapid exhaust of system air when the supply is shut off.
Female thread M8 D M10 E Inch size 07 Nozzle: 0.7 10 Nozzle: 1.0 12 Nozzle: 1.2 15 Nozzle: 1.5 Refer to page 260 for identication method.
Please prepare the padlock at the customers site. -8- 6Dimensions A B E D Piping Center C E D Piping Center AR-D,ARM-D series AW-D,AWM-D,AWD-D series A B C D E AR20(K)-D,AR20M(K)-D AW20(K)-D,AWM20-D,AWD20-D Applicable Part No.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as 3% or less of the rated voltage. 3.
Connection thread Recommended proper torque [Nm] M5 1.5 to 2 1/4 8 to 12 3/8 15 to 20 2. Do not allow twisting or bending moment to be applied other than the weight of the equipment. Provide separate support for external piping, as damage may otherwise occur. 3.
Check for the following during regular maintenance, and replace components as necessary. a) Scratches, gouges, abrasion, corrosion, rust b) Leakage c) Twisting, flattening or distortion of tubes and hoses d) Hardening, deterioration or softening 6. Do not repair or patch the replaced tubing, hoses or couplers for reuse. Do not disassemble the S coupler. 7.
Check for the following during regular maintenance, and replace components as necessary. a) Scratches, gouges, abrasion, corrosion b) Leakage, refer to item 3 regarding taper thread leakage. c) Twisting, flattening or distortion of tubing d) Hardening, deterioration or softness of tubing 3. Do not repair or patch the replaced tubing or fittings for reuse. 1.
AMV15 SP ZCUK 0.015 Inlet pressure (MPa) AMJ AFJ 0.01 AMV AMV AMV15 AMV160 AMV75 AMV37 AMV6 AMV3 ZH -X185 0.005 Related Products 0 100 200 500 1,000 2,000 5,000 10,000 20,000 Flow rate (L/min [ANR]) Dimensions AMV3, 6, 15, 37 AMV 75, 160 B Exhaust Exhaust A A B Port size IN IN C E 8 x d Flange part Model Port size A 231 305 410 710 562 860 B 123 153 210 210 500 500 C 80.7 105.3 d 19 19 E
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46
Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.
Fittings & Tubing Air Cylinders Rotary Actuators Size: 50 Single shaft Double shaft 8 x M8 x 1.25 depth 8 (Opposite side 4 locations) 118 44 62 4 x 9 (Mounting hole) 48 20 15 11 0 0.2 15 (g6) 14 0 0.2 25 (h9) 17 M5 x 0.8 (Vacuum suction port) 15 (g6) 25 5 Auto switch 2 x Cushion valve (Width across flats 3) 9.5 9.5 0 0.030 5 36 2.5 98 7.5 6 7.5 6 108 5 33 14.5 41 A port 2 x Rc1/8 B port 8.5
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket 2-port size (Option) Maintenance space M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70
Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution