SMC Corporation of America
Elite Part Number Search
Search Results "ZPY50CS-N6-A8"

D-LC05 D-LC30 D-LC50 6-10-44 45 Auto Switch Series C76 Contact Protective Box/CD-P11, CD-P12 Differential Response of Auto Switch The auto switch of D-A7/A8 type, D-A7H/A80H type, D-A73C/A80C type, D-C7/C8 type, D-C73C/C80C type are not incorporated with a contact protective circuit.

C96S C96SW C96Y CP96S CP96SW Double acting, Single rod Double acting, Double rod Double acting, Single rod Double acting, Single rod Double acting, Double rod XA0 to 30 XA0 to 30 XA0 to 30 XA0 to 30 XA0 to 30 Standard type C96 Smooth type Standard type CP96 Symbol: A0 Symbol: A1 Symbol: A2 Symbol: A3 Symbol: A4 C DA C0.5 30 RD 30 30 A H H H W1 H L T H Symbol: A8 Symbol: A9 Symbol: A5 Symbol

BBA2: For D-A7/A8/F7/J7 types D-F7BA/F7BAV auto switches are set on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, BBA2 is attached.

list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8

list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8

list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8

list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8

list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6 to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8

Double Acting, Single Rod Double Acting, Double Rod Double Acting, Single Rod Double Acting, Double Rod Symbol: A0 Symbol: A1 Symbol: A2 Symbol: A3 DA C0.5 C 30 30 H H W1 T H A H Symbol: A4 Symbol: A5 Symbol: A6 Symbol: A7 RD B RD AL MM AL MM 30 H L 30 30 30 H L W H H Symbol: A8 Symbol: A9 Symbol: A10 Symbol: A11 C0.5 file chamfer AL B MM WA C R sphere TP R sphere DC 30 H W1 T H H H Symbol

o f y o e y g e e n e Auto switch R ra g k k n n io ra at f ot f o o n e io g at e Angle adjustment range 3 ot n +4 0 R ra g n 0 n io at ot ra R 18 R n ot io ve R at at oo io ot ot R n gr ra y ng at ke e of +4 0 io n 0 ra 19 ng e e ov of o ke gr y Switch A Switch B Proper Auto Switch Mounting Position at Rotation End CDRA1W30 CDRA150 to 100 Auto switch D-A5 (A6/F5/J5) Auto switch D-A7 (A8

C1=C (mm) D1= Y L2 max D2 Size (mm) 10 L1 max X D1 Size 2 to 8 Y-1 3 C1 L1= 10 15 4 to 14 X-3 3 3 to 9 Y-1.5 3 to 4 Y= C2 L2= 15 20 5 to 18 X-4 3 to 4 3 to 10 Y-1.5 3 to 5 X= D2= 20 30 6 to 20 X-4.5 3 to 5 3 to 13 Y-2 3 to 6 C2=C 30 40 6 to 22 X-5 3 to 6 6 to 15 Y-4.5 3 to 8 Symbol: A7 Symbol: A8 The short shaft can be further shortened by machining it into a stepped round shaft with male

X L1 max D1 X L1 max D1 10 4 to 14 X-3 3 2 to 14 X-1 3 15 5 to 18 X-4 3 to 4 3 to 18 X-1.5 3 to 4 20 6 to 20 X-4.5 3 to 5 3 to 20 X-1.5 3 to 5 30 6 to 22 X-5 3 to 6 3 to 22 X-2 3 to 6 15 3 to 9 Y-1.5 3 to 4 20 3 to 10 Y-1.5 3 to 5 30 3 to 13 Y-2 3 to 6 40 6 to 15 Y-4.5 3 to 8 86 Simple Specials CRB2 Series Axial: Top (Long shaft side) Axial: Bottom (Short shaft side) Symbol: A7 Symbol: A8

Symbol: A8 The short shaft can be further shortened by machining it into a stepped round shaft with male threads. (If shortening the shaft is not required, indicate for dimension Y.) Applicable shaft type: W Equal dimensions are indicated by the same marker. (If not specifying dimension C2, indicate instead.)

Q1 = M D1 = Y = C1 = C L2 = Q2 = M C1 L1 = X = L1 = X = (mm) (mm) (mm) D1 X 9 to 18 10 to 20 L2 max Y 2 Y 3 Y 7 to 9 8 to 10 Q2 M5 M6 L1 max X 4 X 4 Q1 M5 M6 X 3 to 18 3 to 20 L1 max X 2 X 2 Size 10 15 Size 10 15 Size 10 15 3.5 to 4.9 3.5 to 5.9 Symbol: A7 Symbol: A8 Symbol: A6 The short shaft can be further shortened by machining it into a stepped round shaft.

Technical Data 1519 A CY1L Series Auto Switch Mounting Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range (mm) Bore size Auto switch model 6 10 15 20 25 32 40 D-A7 /A8 D-F7 /J7 6 6 6 6 6 6 6 3 3 4 3 3 3 3.5 D-F79F 4.5 4.5 4.5 4.5 4.5 4.5 4.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

Basic Type ZP Series Model Connection thread Tightening torque [Nm] ZP(2 to 8)(J/K)--A8 M8 x 1 1.5 to 2.0 ZP(10 to 32)(J/K)--A10 M10 x 1 2.5 to 3.5 ZP(40/50)(J/K)--A14 M14 x 1 6.5 to 7.5 Lock ring Adapter Compact Type ZP3 Series Model Connection thread Tightening torque [Nm] ZP3-(015 to 035)JM6 x 0.75 1.5 to 1.8 ZP3-(015 to 035)KM8 x 0.75 2.0 to 2.5 ZP3-(04 to 16)(J/JB/K)Pad 2.

Rod End Shape Symbol: A1 Symbol: A2 Symbol: A3 Symbol: A4 Symbol: A5 Symbol: A6 Symbol: A7 Symbol: A8 Symbol: A9 Symbol: A10 Symbol: A11 Symbol: A12 Symbol: A13 Symbol: A14 Symbol: A15 Symbol: A16 Symbol: A17 Symbol: A18 Symbol: A19 Symbol: A20 Symbol: A21 Symbol: A22 Symbol: A23 Symbol: A24 Symbol: A25 Symbol: A26 Symbol: A27 Symbol: A28 Symbol: A29 Symbol: A30 41 Series NCA1 Medium Duty

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Switch A Switch B Proper Auto Switch Mounting Position at Rotation End CDRA1W30 CDRA150 to 100 Auto switch D-A5 (A6/F5/J5) Auto switch D-A7 (A8/F7/J7) Operating range at proper mounting position (Lm/2) Operating angle m: Converts the operating range

Applicable shaft types: S, W D20Q1 = M C1 = C D1 = Y = L2 = C1 Q2 = M L1 = X = L1 = X = (mm) (mm) (mm) L1 max X 4 X 4 Q1 M5 M6 Q2 M5 M6 X 3 to 18 3 to 20 L1 max X 2 X 2 D1 X 9 to 18 10 to 20 L2 max Y 2 Y 3 Y 7 to 9 8 to 10 Size 10 15 Size 10 15 Size 10 15 3.5 to 4.9 3.5 to 5.9 Symbol: A7 Symbol: A8 Symbol: A6 The short shaft can be further shortened by machining it into a stepped round

D-A7/A8, D-A7H/A80H, D-A73C, A80C, D-Z7/Z8, D-A9 The above auto switches do not have built-in contact protection circuits. 1. The operating load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100V or 200VAC. A contact protection box should be used in any of the above cases, as the life of the contacts may be reduced.