Alarm Code.01 to 21,24,25,28,29,32: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. *Alarm code 02 and 16 are alarms only for HRZ008-L/L1-F. *Alarm code 28 is an alarm only for HRZ010-W*S-F.
Key lock setting 0 0 to 3 Control mode setting , AT sensitivity setting 2.0 0.0 to 999.9 PB (heating) range setting 7.0 0.1 to 200.0% I constant setting 250 0 to 3600 D constant setting 0 0 to 3600 Heating for the proportional frequency setting 2 1 to 120 ARW setting 100.0 0.0 to 100.0 PB (cooling) range setting 0.50 0.0 to 10.00 Cooling for the proportional frequency setting 2 1 to 120 01
11 70 h 2)-700.00mm GW [OUT Data]Address.6 Address.9 Address.7 Address.6 01h 00h 15bit 8bit 7bit 0bit (H) 00 01 11 70 h (H) Address.9 Address.8 70h 11h 15bit 8bit 7bit 0bit (L) 00 01 11 70 h (L) 0.01mm 2 -700.00mm -7016 FFFEEE90h PLC FF FE EE 90 h Address.7 Address.6 FEh FFh 15bit 8bit 7bit 0bit (H) FF FE EE 90 h (H) Address.9 Address.8 90h EEh 15bit 8bit 7bit 0bit (L) FF FE EE 90
IR2000 : G43-2-01 G43-P2-N01-X30 IR2010 : G43-4-01 G43-P4-N01-X30 IR2020 : G43-10-01 G43-P10-N01-X30 Port size 02 : 1/4 Note4) Set pressure Thread type NIL:Rc N:NPT 0: 0.005~0.2MPa 1: 0.01~0.4MPa 2: 0.01~0.8MPa F:G (Note 3) The pressure gauge is not attached and becomes bundled shipment. (Note 4) One type only. 4. Marking on product Product name plate MAX.SUP.PRESS. MAX.SUP.PRESS.
IR3000 : G43-2-01 G43-P2-N01-X30 IR3010 : G43-4-01 G43-P4-N01-X30 IR3020 : G43-10-01 G43-P10-N01-X30 Set pressure Thread type NIL:Rc F:G 0: 0.01~0.2MPa 1: 0.01~0.4MPa 2: 0.01~0.8MPa N:NPT (Note 3) The pressure gauge is not attached and becomes bundled shipment. 4. Marking on product Product name plate MAX.SUP.PRESS. MAX.SUP.PRESS. MAX.SUP.PRESS.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WEN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (16 points) 2 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#B (8 points) 0 1 EX600-DY
Content 0 to 5 A channel number of 0 to 63 is displayed. 6 Input/Output Type: 00 = Reserved, 01 = Input, 10 = Output 7 -68No.EX-OMN0028-B Diagnostic type Bit No.
. (3) Common supply pressure (PV) connecting port size (4) Common vacuum burst pressure (PD) port Note 2) 01 Rc1/8 01N NPT1/8 01F G1/8 M5 M50.8 NIL Without PD port (PV = PD) M5 M50.8 PVPD Note 2)Refer to model indication for single unit (4) for the combinations of supply valve and release valve selectable. 14 - Doc. no.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
Description Part number Remarks Panel mount adapter ZS-39-B Panel mount adapter + Front protective cover ZS-39-D Front protective cover ZS-39-01 Lead wire with connector + connector cover ZS-39-5G 5 cores, 2 m R1/8 conversion adapter ZS-39-N1 NPT1/8 conversion adapter ZS-39-N2 DIN rail mounting adapter ZS-39-R : Made to Order -10No.PS-OMM0005-J Summary of Product parts Names of individual
Alarm Code.01 to 20, 22, 24, 25: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. Alarm Code.21, 28: Eliminate the error cause, and power cycle the main breaker to enable error recovery to take effect.
Alarm Code.01 to 08, 10 to 19, 22, 24, 29, 30: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. Alarm Code.09: Eliminate the error cause.
Rod End Nut Material: Rolled steel -03 32-01 -03 Applicable pin O.D. 0.040 0.076 0.040 0.076 0.050 0.093 0.050 0.093 0.050 0.093 0.050 0.093 0.050 0.093 0.065 0.117 Bore size (mm) Part No.
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
1 Metering Valve with Silencer Series ASN2 Superior sound reducing performance Over 20 dB at max. flow rate Cylinder speed easily set Shape of needle is the same as that of speed controller Retainer prevents accidental loss of needle Model Model Port size Effective area (mm 2) Weight (g) ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 M5 x 0.8 10-32 UNF 1.8 1.8 3.6 6.5 16.6 24.5 5 5 17
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Description Material Part No. # pieces 3 port switching valve (For operation control) VOA301-M VO307E, D-X56 1 e Relay valve Pressure gauge Diaphragm assembly Valve assembly NLP seal PNY seal Wear ring O ring VR4152-00-0 GA46-10-01 12702A 12705A NLP-100A PNY-25 SW-100 X 6 X 2 JIS B2401P3 1 1 1 1 2 2 2 1 r t y u i o !0 !
Order Made 2 With IN-OUT Flange 1 With Pressure Differential Gauge (GD40-2-01) A pressure differential gauge can be installed in the body to check the life of the filter element. It allows for easier piping and compact size. For easier flange piping.
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-l02 : E4-l03 : E4-l04 1 4 3 8 1 2 1 4 1 2 : E6-l06 : E6-l10 3 4 1 : E5-l04 : E5-l06 : E3-l02 : E3-l03 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) l in the gauge part number (e.g.
IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L/ IDG50L Port size With separator regulator Symbol Bore Size 3 5 10 20 30 50 60 75 100 V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Specifications with element service indicator are also available. See the order made section on page 33.