KFN-04 KFN-06 KFW-04 KFW-06 KFV-04 KFV-06 KFS-04 KFS-06 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
13 10 30 14 3 x Rc3/8 (Piping port) 77.5 3 x Rc3/8 (Piping port) 43 10 27 45 45 Width across flats 100 M24 x 1.5 44 112 30 Max. 65 Max. 65 50 52 Hole: 18 +0.027 0 Width across flats 24 R24 Shaft: 18 0.050 0.093 28 +0.5 +0.1 4 x M6 Thread depth 12 61 129 + Stroke 110 85 259 + Stroke Hole: 18 +0.027 0 2 x M6 Thread depth 6 Shaft: 18 0.050 0.093 Press-fit spring pin 5 x 40 L 38 17 32 37 48
^-2 1: 10^-1 2: 10^0 3: 10^1 4: 10^2 5: 10^3 6: 10^4 7: 10^5 8: 10^6 AC_E_L (Setting L of the accumulated flow value conversion factor) Setting of the accumuated flow value conversion factor Unit specification (Unit): When "L" is selected. 1071 0x042F 0 R/W U8 2 Y 0: 10^-2 1: 10^-1 2: 10^0 3: 10^1 4: 10^2 5: 10^3 6: 10^4 7: 10^5 8: 10^6 Accumulated value setting AC_E_G (Setting G of the accumulated
Enable Generates an error. 1 Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Sets the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
OUT 28. 3 4. 99 10. 7 16. 3 3 6 3. 5 IN OUT 78. 5 16. 7 32. 4 48. 1 10 4 6. 9 IN OUT 201 45. 6 86.3 126 16 6 15 IN OUT 314 73 136 199 20 8 21 IN OUT 491 119 218 316 25 10 28 IN OUT 804 207 368 529 32 IN 12 34 Note) Prevent load from being applied to the piston rod when the piston rod is being retracted. d) Spring extended type [C(D)U(K)*-*T] (N ) Operating pressure Mpa Pressure receiving
A 10 B 14 D 14 Port size M5 x 0.8 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 3/4 Model Note 1) E100-M5 E200-01 E200-02 E200-03 E300-02 E300-03 E300-04 E400-02 E400-03 E400-04 E400-06 30 23.5 28 B Center of F.R.L. body D A 32 30 30 32 36 36 E500-06 3/4 32 40 44 Piping adapter AC50, AC55, AC60, AC50A AC60A, AC50B, AC55B AC60B, AF50, AF60, AR50 AR60, AL50, AL60, AW60 E600-06 3/4 48 53 35 E600-10 1
Refer to LECSS2-T Operation Manual,section 3.5 for input/output signal details. -10- 3.3.2 Source Sink I/O interfaces Connection example An example wiring diagram for Sink I/O is shown below Driver Servo amplifier () CN8 (Note 16) Short-circuit connector (Packed with the servo amplifier) 10 m or less driver) (Note 12) CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power
M1 Weight (g) ASV220F-U10/32-03 ASV220F-U10/32-07 5/32" 1/4" 10-32 UNF 10-32 UNF 8 8 9.3 12 9.6 9.6 22.8 23.6 27.6 28.4 11.1 11.1 31.4 31.4 28.6 28.6 27.7 27.7 24.9 24.9 12.7 13.7 8 9 Reference U10/32 thread dimensions after installation.
40 50 63 32 40 50 63 12 8 30 9 5 27.5 16 12 32 11.5 7.5 30 14 10 37.5 14.5 10.5 35 16.5 12.5 42.5 17.5 13.5 40.5 Note) The actual mounting position should be adjusted after confirming the auto switch performance.
-20 -25 -30 Cylinder model Mounting bolt size CUJB4-4 -6 -8 -10 -15 -20 CUJB6-4 -6 -8 -10 -15 -20 -25 -30 CUJB8-4 -6 -8 -10 -15 -20 -25 -30 CUJB10-4 -6 -8 -10 -15 -20 -25 -30 M2.5 x 21 l M2.5 x 23 l M2.5 x 25 l M2.5 x 27 l M2.5 x 32 l M2.5 x 37 l M3 x 22 l M3 x 24 l M3 x 26 l M3 x 28 l M3 x 33 l M3 x 38 l M3 x 43 l M3 x 48 l M3 x 22 l M3 x 24 l M3 x 26 l M3 x 28 l M3 x 33 l M3 x 38 l M3
Approx. 5.6k Switch DICOM 24VDC 10% 150mA Approx. 5mA VCES 1.0V ICEO 100 A (2) Digital output interface DO-1 A maximum of 2.6V voltage drop occurs in the driver. If polarity of diode is reversed, servo amplifier will fail. Servo amplifier Driver driver ALM, etc. Load DOCOM (Note) 24VDC 10% 150mA Note.
AWD30 30 30 32 AC40 AF40, AR40, AW40 AL40, AFM40, AFD40 AWM40, AWD40 36 36 32 AC40-06, AF40-06, AR40-06, AW40-06 AL40-06, AFM40-06, AFD40-06 44 40 32 E500-06 3/4 3/4 1 E600-06 E600-10 AC50, AC55, AC60, AC50B, AC55B, AC60B AF50, AR50, AL50, AF60, AR60, AL60 53 48 35 Notes) in model numbers indicates a thread type.
M 100 Cable length 0.2 or more I/O occupation area (Inputs/Outputs) 1 station occupied (Remote I/O 32 points/32 points)/(Remote register 4 words/4 words) 2 stations occupied (Remote I/O 64 points/64 points)/(Remote register 8 words/8 words) Up to 42 (when 1 station is occupied by 1 driver), Up to 32 (when 2 stations are occupied by 1 driver), when there are only remote device stations.
10 10 150.5 15 26 54 10 8 M8 x 1.25 6 11 25 to 800 25 to 650 35 50 32 80.5 27 70 46 21 52 24 20 28.5 10.5 40 10 12 162.5 17 27 59 13 11 M8 x 1.25 9 11 25 to 800 25 to 650 35 60 32 98.5 27 85 23 64 24 20 28.5 13.5 40 10 15 17 26 67 18 11 M10 x 1.25 9 48.5 174 14 25 to 750 25 to 600 40 70 37 32 23 78 25 15.5 52 14 17 21 30 72 23 13 M12 x 1.75 11 117.5 102 55 26.5 36 189 17 25 to 750 25 to
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
(mm) Connection thread R Model A M Weight (g) Note) D2 L1 L2 10 D1 KRL06-02S KRL06-01S 1 8 12 22 33 13 21 35 25 26 36 25.5 23 27 29 24.5 28.5 30.5 27 30 32 36 31 33 37 10 20 29 27.5 1 4 19 4.2 14 17 12 14 17 12.8 6 Applicable tubing 9.0 3 8 1 8 KRL06-03S 28 14.9 KRL08-01S KRL08-02S KRL08-03S KRL10-01S KRL10-02S KRL10-03S 1 4 3 8 1 8 1 4 3 8 30 31.5 32 33 34.5 15.2 12 23 8 20.5 21.6 14.9 21.6
Grease for food part no.: GR-H-010 (10 g) Standard grease part no.: GR-S-010 (10 g) HYQB20-PS HYQB25-PS 20 25 HYQB20-PS HYQB25-PS 20 25 HYQB32-PS HYQB40-PS HYQB50-PS HYQB63-PS HYQB32-PS HYQB40-PS HYQB50-PS HYQB63-PS 32 40 50 63 32 40 50 63 HYQB20H-PS HYQB32H-PS Set of nos. above o, !0, !4. Set of nos. above o, !0, !4.
Grease for food part no.: GR-H-010 (10 g) Standard grease part no.: GR-S-010 (10 g) HYQB20-PS HYQB25-PS 20 25 HYQB20-PS HYQB25-PS 20 25 HYQB32-PS HYQB40-PS HYQB50-PS HYQB63-PS HYQB32-PS HYQB40-PS HYQB50-PS HYQB63-PS 32 40 50 63 32 40 50 63 HYQB20H-PS HYQB32H-PS Set of nos. above o, !0, !4. Set of nos. above o, !0, !4.
Refer to "LECSB2-T Operation Manual (Simplified Edition)", section 5.7 for how to set the Point table. -32- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including pulley (Pulley ratio 4/7) ratio) Parameter *1,*2 Para.