Its maximum operating temperature is 150? C. KQB2 fittings can be used with fluid, and in environments having a large temperature change. Configuration variations have been improved to 17 models. Applicable tube sizes are +3.2 to +16 and 1/8" to 1/2".
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: 10 Torr~150 psig (10Torr~9.9kgf/cm 2 ), Effective area (Cv): 0.14, Piping: side or bottom, Ambient and fluid temperature: 40 - 140F (no freezing), VALVE, MECH'L 1/8 NPT, VALVE, VM (VFM/VZM) MECHANICAL VALVE, CA, VM BODY PT 1/8NPT (F), 0.2178 lb
101.2kPa., MANIFOLD BASE, VALVE, VP3/5/7 SOL VALVE 3-PORT, GJ, VP3/5/7 BODY PT 3/8, 1.16844 lb, SeriesBase modelPiping specificationsApplicable valveApplicable stations Note)Manifold base Weight: W [g] Stations: n 1P (SUP)port type3R (EXH)port typePort sizeVP500VV3P5-41CommonCommon3/8VP5442 to 20 stationsW = 190n + 150
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
Port size: 1/2, 3/4, 1, Applicable thread type: Rc, G, NPT, NPTF, Type of actuation: Normally open/Normally closed (Changeable), Operating pressure range: 0.2 to 0.9 MPa, Impact/Vibration resistance: 150/50 m/s, VALVE AIR PILOT, VALVE, VG/VGA VALVE, LA, VG BODY PT >3/4, 2.10442 lb
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
OUT1, OUT2: OrangeIP65Operating: 23 to 122F, Stored: 14 to 140F (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/
Part Number Description: VACUUM REGULATOR ASSEMBLY Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 150 Family Description: IRV VACUUM REGULATOR Class Code: CC Part Code: 1 Reference Code: J Click here to report information errorImage shown may not match exact part number
C (swivel elbow type -5 to 150?C).??With their?stainless steel 316 construction and unique non-rubber seal insert connection, these grease-free fittings offer high levels of corrosion resistance, and can be used with numerous piping materials including FEP, PFS, soft and regular nylon, polyurethane and polyoelfin.?
KG can be used for vacuum 100 kPa and pressures up to 1 MPa (~150 PSI). This fitting is available in 27 different body styles, with connection sizes from M5 to + R(PT), and tube sizes from 4mm OD to 12 mm OD., FITTING, MALE ELBOW S/S, CONNECTORS, KG/KQ(X23) 1-TOUCH STAINLESS, LG, KQ(X23) 12MM, .13712 lb, Applicable tubing O.D.
KG can be used for vacuum 100 kPa and pressures up to 1 MPa (~150 PSI). This fitting is available in 27 different body styles, with connection sizes from M5 to + R(PT), and tube sizes from 4mm OD to 12 mm OD., FITTING, UNIVERSAL MALE ELBOW, CONNECTORS, KG/KQ(X23) 1-TOUCH STAINLESS, JX, KQ(X23) 10MM, .08981 lb
KG can be used for vacuum 100 kPa and pressures up to 1 MPa (~150 PSI). This fitting is available in 27 different body styles, with connection sizes from M5 to + R(PT), and tube sizes from 4mm OD to 12 mm OD., FITTING, UNIVERSAL MALE ELBOW, CONNECTORS, KG/KQ(X23) 1-TOUCH STAINLESS, LX, KQ(X23) 12MM, .11812 lb
Its maximum operating temperature is 150 C. KQB2 fittings can be used with fluid, and in environments having a large temperature change. Configuration variations have been improved to 17 models. Applicable tube sizes are +3.2 to +16 and 1/8" to 1/2".