10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)0.8 to 5 V ?2.5% F.S.?
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above)Variable (0 or above)1 to 5 V ?2.5% F.S.?
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release
The ZSE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen. Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]