SMC Corporation of America
Elite Part Number Search
Search Results "IS10T-40-N04-LP-D"

50 [mm] 50mm CCW CW 10 20 30 40 50 60 [mm] b) CW )50mm =0() =10 =-10 50mm CCW CW -50 -40 -30 -20 -10 0 [mm] 50mm CCW CW -40 -30 -20 -10 0 10 [mm] 50mm CCW CW -60 -50 -40 -30 -20 -10 [mm] -29- 4/ A 50mm () 5m 5m 10% 15m 20% -30- 5./ 5.1 (LEC ) ,, () EMG() 1000 1 / (Best Pneumatics No UL ,UL1310 Class2 -31- 5.2 5.3. 90100 DC24VSVON a) b) c) d) e) -32- D () 5. 1. 2.() 3

D Constant Setting range : 0.0 to 99.9sec Min. increment : 0.1sec Indicated content : D constant(Ex. : 0.0sec) D C o n s t a n t M O D E < 0 . 0 s e c Function : Sets differential time used for PID control. When 0 is set, this function becomes invalid. 7.

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A9 D-M9 22 (24.5) A 2.8 0.5 W B ( ): Dimensions for D-A93 Bore size (mm) D-A9 A B W 6 10 16 36 11.5 9.5 (7) D-M9 A B W 29.5 5.5 3.5 (1) 29.5 9.5 7.5 (5) 33.5 9.5 0.5 33.5 13.5 3.5 40 15.5 5.5 20 41 15 13 (10.5) 45 19 9 25 40.5 16.5 14.5 (12) 45.5 20.5 10.5 Note) The above mentioned values are indicated as a guide for auto switch

Install to DIN rail Mount them on to the DIN rail and connect the additional high voltage power supply module D-sub connector. High voltage power supply High voltage power supply module module to be added to be added e. Mount the fixing bracket D-sub connector Mount the fixing brackets (included as an accessory) in location D. D : Fixing bracket f.

) (Mounting hole pitch) MAX. 11 VZ3540 (Mounting hole pitch) (Lead wire length) G: 300 mm H: 600 mm 2-M5 x 0.8 (PE port) 4-Rc 1/8 (Piping port) L plug connector (L) VZ3 40-L-01 M plug connector (M) VZ3 40-M-01 3 4 5 3 4 5 (Lead wire length) 300 300 (Lead wire length) : With light/surge voltage suppressor Built-in speed controllers VZ3 50DIN terminal (D) VZ3 40-D-01 3 4 5 3 4 5 Applicable

Rail mounting Direct mounting D-F7BA D-F7lW D-F7lF D-J79W D-A7lH/A80H D-A73C/A80C D-F7l/J79 D-F7lV/J79C D-F9BA D-F9lW D-F9lWV D-F7lWV D-A9l D-A9lV D-F9l D-F9lV D-A79W D-A7l/A80 Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 7 9.5 12.5 15.5 A 10 14 12 14.5 B 10.5 13 16 19 A 13.5 17.5 15.5 18 B 3.5 6 9 12 A 6.5 10.5 8.5

Series 10/11 -CQSX Series10/11 -CQ2X How to Order How to Order Clean room series 10 11 Clean room series 10 11 Relieving type Vacuum type Relieving type Vacuum type C(D)QSX B 20 10 30 A90 C(D)Q2XB 40 10 30 A73 D D With auto switch With auto switch (with built-in magnet) (with built-in magnet) Microspeed cylinder Microspeed cylinder Mounting Cylinder stroke (mm) Bore size Number of auto

XMC Exterior dimensions C D L1 L2 Fn Fc C (Fc) (KF Flange) (CF Flange) J H B A G A Unit:mm Model A B C D Fn Fc G H J P.C.D L1 L2 XMC-16 40 110 38 1 30 34 17 40 26 P.C.D 27 6x4.4 XMC-25 50 120 48 1 40 26 39 28 XMC-40 65 171 66 2 55 70 41 63 36 P.C.D. 58.7 6x6.6 C D L1 L2 Fn Fd Fc C (Fc) (KF Flange) (K Flange) (CF Flange) H J K B A G A Unit:mm Model A B C D Fn Fc Fd G H J K P.C.D L1 L2 XMC-

Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.

+ + + + 8 I/O (NPN/PNP) 9 10 FG () 12 - 3.3. 1 LECP6 2 DIN LECP6D 13 - 3.4. 1 DIN 2 LECP6DINLECP6DDIN 2M4 DIN DIN A DIN ADIN 2 M4 M4 14 - D (100 ) 2mm 2 D 3 40 30mm 50mm ()60mm () 0mm (LE)10mm LEH 25 30mm 60mm 30mm 50mm DIN ) 15 - 4.

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.

Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Vacuum Pressure Switch: ZSE2-0R-15 ZSE2-0R-15 ZSE2-0R-15L ZSE2-0R-15C ZSE2-0R-15CL ZSE2-0R-15CN Indicator light (Red) Pressure setting trimmer Indicator light (Red) Pressure setting trimmer H L SET L SET H 15 15 9 9 2-M2.5 Mounting thread 2-M2.5 Mounting thread 25 25 31 31 600(3000) 42 600(3000) 49.5 40 40 3 3 20 20 18 18 16 16 13 11 13 11 9 9 Vacuum supply port 3.3 Vacuum supply port 3.3

-40 M8 x 1.25 17.7 16 Max. tightening torque (Nm) Model Screw MHZ2-10 M2.5x0.45 0.49 MHZ2-16 M3 x 0.5 0.88 MHZ2-20 M4x0.7 2.1 MHZ2-25 M5 x 0.8 4.3 MHZ2-32 M5 x 0.8 4.3 MHZ2-40 M6x1 7.3 Note) If auto switches D-Y59, D-Y69, or D-Y7P are used, or the auto switch is mounted to the corner of the body, only a tapped body can be used.

Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 How to Order Without auto switch 30 20 CQ2 B D 12 to 25 Without auto switch CQ2 B 32 30 Z D 32 to 100 30 32 Z M9BW B CDQ2 D With auto switch Auto switch With auto switch (Built-in magnet) Nil Without auto switch Mounting Refer to the below table for applicable auto switches.

Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -66, Air Consumption Flow Rate(l/min): 196, Vacuum Port Connecting Port Shape: [Others] NPT1/2, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT3/8, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):