1.5 200 IDF2D 235 Rc 3/8 2.2 300 IDF3D 350 R134a 9 to 12 40C 3.7 430 IDF4D 500 R 1/2 5.5 640 IDF6D 750 R 3/4 7.5 850 IDF8D 1000 1300 IDF11D R134a 11 R 3/4 1500 1300 IDF11C 15 2400 2050 IDF15C/15C1 R 1 22 3700 3150 IDF22C/22C1 40C 13 to 15 R22 37 6100 5200 IDF37C/37C1 R 11/2 55 9000 7650 IDF55C R 2 75 12400 10500 IDF75C 2 1/2B flange 23000 IDF120D 20 120 30 IDF150D 25000 150 40C R407C 3B
0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 * Shown above are reference values.
Water Cooled Aftercooler Series HAW HAA HAW Series HAW can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. As series HAW is watercooled, it can be used where there is high temperature, high moisture and heavy foreign particles.
1 Water Cooled Aftercooler Series HAW Model/Standard Specifications Series HAW can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. As series HAW is watercooled, it can be used where there is high temperature, high moisture and heavy foreign particles.
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
After unpacking the product, store it at a temperature of 40C or less and relative humidity of 75% or less. 7. Do not use the tube in atmosphere or compressed air containing solvent. 5. Clean the tube and the actuator by air blowing to eliminate moisture before connecting them to the circuit with condensation. 8. Do not wipe or clean the product with alcohol.
Solenoid valve part number Allowable voltage range [Ambient and fluid temperatures: 5C or higher and 40C or lower] LPV21-mm-T4 LPV21-6mm-T6(A) LPV22-mmm-T4A LPV22-mmm-T6A 7. Do not use the switch unless the equipment operates normally.
(Full span) or less Hysteresis Pressure switch with digital display and self-contained solid state sensor 3% F.S. (5 to 40C), 5% F.S. (5 to 60C) Accuracy AF 12 to 24 VDC (Ripple 10% or less) Voltage Minimum allowable pressure indicator on digital display AR Open collector 30 V, 80 mA or less Output Light turns ON when pressure drops below the set minimum.
(Full span) or less Hysteresis Pressure switch with digital display and self-contained solid state sensor 3% F.S. (5 to 40C), 5% F.S. (5 to 60C) Accuracy AF 12 to 24 VDC (Ripple 10% or less) Voltage Minimum allowable pressure indicator on digital display AR Open collector 30 V, 80 mA or less Output Light turns ON when pressure drops below the set minimum.
pipe purge air away from dryer 3.6 3.6 3.6 3.6 3.6 3.6 7.25 7.25 A B C Dimension inch 12000 hours service/Maintenance kit Built-in synoptic dryer control panel Non-corrosive shuttle valves Ability to remove dryer towers without disturbing the connecting pipe work Alternative purge plugs available 11 11 11 11 11 11 11 11 Optional dew points . 100F (70C) Standard pressure dew point . 40F (40C
Min. bending radius (mm) Note) 4 Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) Material Polyurethane Color Black(B), White(W), Red(R), Blue(BU), Yellow(Y), Green(G), Clear(C) Burst Pressure Characteristic Curve and Operating Pressure Note) At a temperature of 20C bend the tubing into a U shape.
HAA HAW IDFAE Selection Example AT 1 Correction factor Note) Data symbol 40C Condition Read the correction factor.
ACG20 to 40 AF + ARG + [S] + AL (7) Pressure switch S AF + [S] + ARG ACG20B to 40B AF + AFM + [S] + ARG ACG20C to 40C AF + ARG + AL + [V] ACG20 to 40 Residual pressure relief 3 port valve AW + AL + [V] ACG20A to 40A Port size V AF + ARG + [V] ACG20B to 40B Body size Port size AF + AFM + ARG + [V] ACG20C to 40C Symbol 20 30 40 AW + AFM + [V] ACG20D to 40D 01 02 03 04 1/8 Note 6) When more
Temperature When operating at high temperatures (40C to 80C), there is danger of burns. Confirm that the surface temperature of the filter or the parts for operation are 40C or less, to prevent a burn from occurring. 531
Power supply Note 2) 2 x 1.5 VDC 2A alkali dry cell batteries (continuous use for 15 hours or more) Applicable cylinder Built-in magnet Enclosure IP40 Ambient temperature 10 to 60C temperature range Operating: 0 to 40C, Stored: 10 to 60C (with no freezing or condensation) Operating Environmental resistance Applicable Auto Switches for the Time Required for Stroke/ Operation Count Measurement
(Full span) or less Hysteresis Pressure switch with digital display and self-contained solid state sensor 3% F.S. (5 to 40C), 5% F.S. (5 to 60C) Accuracy AF 12 to 24 VDC (Ripple 10% or less) Voltage Minimum allowable pressure indicator on digital display AR Open collector 30 V, 80 mA or less Output Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
Note1) AF+AFM+[T]+AR AC20C to 40C AF+AR+AL+[V] AW+AL+[V] AF+AR+[V] AC20 to 50 With float type auto drain (N.O.)
Auto current down, Power down input Function Connector Connection method 5 to 40C Operating environment 35 to 85% (with no condensation) Connectors (receptacle, female terminal) Cable should be arranged by customer. Accessories CE marking 1. The combination of Series LC6D and Series LX has been certified for CE marking.
Auto current down, Power down input Function Connector Connection method 5 to 40C Operating environment 35 to 85% (with no condensation) Connectors (receptacle, female terminal) Cable should be arranged by customer. Accessories CE marking 1. The combination of Series LC6D and Series LX has been certified for CE marking.
Min. bending radius (mm) 75 60 48 36 24 25 13 100 15 20 30 60 75 Caution Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) 1. Applicable for general industrial water. Please consult with SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure.