This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., ETHERNET/IP SI UNIT WEB SERVER, SERIAL TRANSMISSION SYSTEM, 645, 200.00000 lb
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., VACUUM MANIFOLD SI UNIT, SERIAL TRANSMISSION SYSTEM, 645, 150.00000 lb
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .44092 lb
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., VACUUM SI ETHERCAT FIELDBUS, SERIAL TRANSMISSION SYSTEM, 645, 200.00000 lb
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series.
Delivery Pressure: J [10 to 1500 psig (0.07 to 10.3 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 20 [2000 psig (14 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: Vespel®, Standard, O-ring Material
Delivery Pressure: J [10 to 1500 psig (0.07 to 10.3 MPa)], Relieving: 1 (Self-relieving, Standard), Material: C (300 SS Series), Ports: 4P (4 Ports), Connections: 4 (NPT 1/4 Inch), Gauge Port, Inlet: 20 [2000 psig (14 MPa)], Gauge Port, Outlet: 20 [2000 psig (14 MPa)], Pressure Gauge Unit: psig/bar (or None in Case of no Gauge), Main Valve Seat Material: PK (PEEK), O-ring Material: VitonÂ
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. Test was performed in both an axial direction and a perpendicular direction to the lead screw. (Test was performed with the actuator in the initial state.) Note 9) The power consumption (including the controller) is for when the actuator is operating.
Ambient temperature [C] 32 Outlet air pressure dew point[C] 10 Power supply voltage (Frequency) *5 Single-phase/Three-phase: 200 VAC (50 Hz) *5 Single-phase/Three-phase: 200/220 VAC (60 Hz) Three-phase: 200 VAC (50 Hz) Three-phase: 200/220 VAC (60 Hz) Single-phase 200 V 810/940 810/940 Power consumption [W] Electric specifications 50/60 Hz *6 Three-phase 200 V 850/1070 850/1070 1450/1890 2000
1000/5000 500/2000 200/1000 100/500 100/200 *Dimension A reference after installation.
3000 4000 5000 0 1000 2000 3000 500 1000 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) AR50(K)-B Rc1 AR60(K)-B Rc1 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 5000 10 0 0 0 5000 10 Flow rate L/min (ANR) Flow rate L/min (ANR) 68 Series AR10-A Series AR20-B to AR60-B Series AR20K-B to AR60K-B Pressure Characteristics
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.