4/RJ08 4 4 12 10 Impact mass m [kg] Impact mass m [kg] Impact mass m [kg] RJ1007L 3 3 8 RJ0806L RJ0604 2 6 2 4 RJ0806H RJ1007H 1 1 RJ0805 RJ1006 2 0 0 0 0 500 1000 1500 2000 0 500 1000 1500 2000 0 200 400 600 800 1000 Collision speed [mm/s] Collision speed [mm/s] Collision speed [mm/s] Graph !6/RJ14 Graph !8/RJ27 Graph !

CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000

-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.

800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VP4 VZ1120--M5 (Piping: 6 x 1 m) VZS VFS VS4 AS2001F-06/AN120-M5 AS2301F-M5-06/AN120-M5 Speed controller/Silencer It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.

trimmer Pressure setting trimmer SET HYS SET HYS L L H H L L H H 15 15 Indicator light (Red) Indicator light (Red) 23 23 SE1-01-16C/-17C SE1-01-16/-17 I Z I Z Pressure setting trimmer 2 Pressure setting trimmer 1 Pressure setting trimmer 2 Pressure setting trimmer 1 SET1 SET2 L L H H 15 SET1 SET2 L L H H 15 Indicator light (Red, Green) 23 Indicator light (Red, Green) 23 600 (3000) 56.5 600

IS ISG ZSM 769 Series ZSE3/ISE3 Dimensions/Switch Only Grommet type 30 SE3I Z 01 T1 20.5 RESET button DOWN button SET button UP button Lead wire length 600 3.5 (3000) 40.5 8.5 01: R 1/8 T1: NPTF 1/8 2 x 3.5 Mounting hole 13 M5 x 0.8 Connector type 30 SE3C I Z 01 T1 20.5 RESET button DOWN button SET button UP button Lead wire length 600 3.5 (3000) 10 39 8.5 01: R 1/8 T1: NPTF 1/8 2 x 3.5 Mounting

Bore size Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ1101 Port size: 6 one-touch fitting 800 700 600 500

W Wmax Confirm that the applied load mass W [g] does not exceed the allowable load mass. 600 g 21.2 oz Allowable load mass Wmax 400 500 14.1 17.6 300 10.6 200 7.0 0.0 100 0.0 3.5 0 15 30 45 60 75 90 From Table 1, find the correction values for the distances to the moment center. Calculate the static moment M [Nm]. From Table 3, find the allowable moment Mmax [Nm].

, 200, 250, 300, 350, 400, 450, 500, 600 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Up to 2500 Cylinder model: MDWBD32-50-NW-M9BW Double clevis The manufacturing of intermediate strokes is possible.

C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC6 Piston rod and rod end nut

, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Intermediate strokes are available, too.

When in need of a valve with a lead wire longer than 600 mm, place an order for a valve without a connector and connector assembly. Note) Mounting screws are attached.

Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10

600 400 400 200 200 Ambient 5C Ambient 5C 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 [50 Hz] Circulating fluid temperature [C] [60 Hz] Circulating fluid temperature [C] 012 018 024 A W HRS -20 (Single-phase 200 to 230 VAC) 1000 1000 Ambient 40C Ambient 32C Ambient 25C Ambient 40C 800 800 600 600 Ambient 32C 400 400 Ambient 5C Ambient 20C Ambient 25C Ambient 5C Ambient 20C 200

109 35 32 27 75 32 20 58 9 9 21 14 58 11 58 M8 x 1.25 7 18 5.5 M18 x 1.5 55 1/4 176 63 to 600 109 35 32 27 90 38 20 70 11 9 21 14 58 11 72 M10 x 1.5 7 18 7 M18 x 1.5 69 1/4 176 80 to 750 130 40 37 32 100 50 25 82 11 9 28 20 71 13 89 M10 x 1.5 10 22 7 M22 x 1.5 80 3/8 210 100 to 750 131 110 10 40 37 41 125 60 30 100 14 10 29 20 71 16 M12 x 1.75 26 8 M26 x 1.5 100 1/2 212 Flange brackets

(Symbol 1) IN (Symbol 2) OUT Nil 300 mm 600 mm 1000 mm For the LVM11, the type with power-saving circuit is standard. 6 10 Coil voltage 10R4 N.O. 2 Option (Symbol 3) IN (Symbol 2) OUT Symbol Voltage Nil None Bracket Manual override Bracket, Manual override 5 6 24 VDC 12 VDC 1 2 3 10R6 N.C.

383.2 402.2 421.2 440.2 459.2 478.2 497.2 516.2 535.2 554.2 573.2 592.2 L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512 L3 210.5 223 248 260.5 285.5 298 323 335.5 360.5 373 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 L4 200 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575 600

715 40 336 365 394 424 453 483 512 541 571 600 806 953 25 113 189 264 50 517 558 600 642 684 725 767 809 850 1142 1351 63 742 779 815 851 887 923 959 995 1032 1285 1465 32 181 302 422 Additional Weight (g) 40 317 528 739 12 16 20 25 32 40 50 63 Bore size (mm) 50 Both ends tapped 19 6 6 495 825 1150 Rod end male thread Male thread 3 6 12 24 52 54 106 106 63 841 1400 1960 Nut 16 34 34 64

VX2 Symbol Symbol VXD 3 X60 4 X133 Lead Wire Length: 600 mm Specification Seal Material: Kalrez Specification VXZ VXE X60 VDW Standard model no. X133 VDW Standard model no. VXP VXR VXH VXF VX3 VXA VCHm VDW VQ LVM VCA VCB VCL VCS VCW 259 Series VDW Specific Product Precautions 1 Be sure to read this before handling.

394 424 453 483 512 541 571 600 806 953 50 517 558 600 642 684 725 767 809 850 1142 1351 63 742 779 815 851 887 923 959 995 1032 1285 1465 2.