Assuming that the tube I.D. is 2 mm, the piping capacity is as follows: V = /4 x D2 x L x 1/1000 = /4 x 22 x 1 x 1/1000 = 0.0031 L (2) Assuming that leakage (QL) during adsorption is 0, find the average suction flow rate to meet the adsorption response time using the formula on the front matter 17.
Outlet Air Temperature 50C 70C 100C Inlet air temperature (C) Correction factor Air flow (l/min (ANR)) Model 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 35 40 44 35.5 40 42 37 40 41.5 38 40 42 34.5 38 40 33 36.5 38 34 36 37 34 35 36 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 HAA7 Air inlet Air outlet Air cooled style after cooler HAA15 HAA22 Auto-drain HAA37 Min.
Model A B C A B C A B C A B C 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 34.5 38 40 33 36.5 38 34 36 37 34 35 36 35 40 44 35.5 40 42 37 40 41.5 38 40 42 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 HAA7 HAA15 HAA22 Maintenance HAA37 Caution 1. Inspect the cooler at least once a week and clean it to prevent it from becoming obstructed. 2.
125, 140 M30 x 1.5 54000 36000 3 55000 160 M36 x 1.5 71000 55000 Option/Thread nominal size JA20-8-100 JA25-10-150 JA32-10-100 JA40-12-125 JA40-12-150 JA40-12-175 JA50-16-150 JA63-16-200 JA80-20-250 20 M8 x 1 1100 1100 1000 0.5 Series JA 25 M10 x 1.5 2500 2500 2000 0.5 Precautions 32 M10 x 1 2500 2500 2000 0.5 30, 40 M12 x 1.25 4400 4400 4400 0.75 Be sure to read before handling.
V = 2gH/1000 x 60 Obtain the total amount of the workpiece. Total weight m = 10 x 0.1 (kg) = 1 (kg) Obtain the intersection of the transfer speed V and the total weight of workpiece m.
Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com V (mm/s) = Auto switch operating range (mm) Load operating time (ms) 1000 3. Keep wiring as short as possible.
Standard equipped with shock absorber -X 75 100 125 150 200 250 300 20 25 32 40 50 63 80 100 20 25 32 40 50 20Series MGC P . 8-21-6 Data Series MGG V V V V V V V V V V V V V V Guide Cylinder Guide Table Cylinder with Turntable Series MGC Long stroke Bore size (mm) Standard stroke (mm) Compact type of series MGG Lightweight, space-saving 250 300 350 400 450 500 600 700 800 900 1000 1100 1200
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PROGRAMLESS CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, .00000 lb, Stroke Model1002003004005006007008009001000Manufacturable stroke range [mm]LEFS32??????????100 to 800
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PROGRAMLESS CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, .00000 lb, Stroke Model1002003004005006007008009001000Manufacturable stroke range [mm]LEFS32??????????100 to 800
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, PNP, ACTUATOR, ELECTRIC ACTUATOR, KC, 30MM LE ELECTRIC ACTUATOR, .00000 lb, ModelBoltMax. tightening torque [N?m]Max. screw-in depth [mm]LER 30M8 x 1.2512.016
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.? Through the combination of parallel I/O inputs, 14 points of positioning are available.? The speed and acceleration of the positioning can be set by the switch for each operating direction.? A single signal sent to a dedicated terminal returns an actuator to
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PROGRAMLESS CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, .00000 lb, Stroke [mm]Model3050100150200250300350400450500Manufacturable stroke range [mm]LEY16PPPPPPP????10 to 300
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PROGRAMLESS CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, 1.98416 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PROGRAMLESS CONTROLLER, ACTUATOR, ELECTRIC ACTUATOR, 2C, LE ACTUATOR, NO SIZE RATING, .00000 lb, Stroke Model1002003004005006007008009001000Manufacturable stroke range [mm]LEFS32??????????100 to 800
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, .00000 lb, Stroke Model30050060070080090010001200150018002000LEFB32???????????
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, PNP, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, .00000 lb, Stroke Model30050060070080090010001200150018002000LEFB32???????????