Stainless steel Nickel plated Stainless steel Gas soft nitrided Gas soft nitrided Replacement Parts No Description Material ML1C25G O ring O ring O ring Needle gasket O ring O ring O ring Tube gasket Cushion seal Piston sael Scraper 1 Scraper 2 Bypass gasket O ring ML1C32G C-7 SO-015-24 SO-016-9 C-4 SO-010-16 C-6 AS568-048 NLP-32A RCS-10 GMY32 ML1C40G C-7 SO-020-31 SO-015-20 C-4 SO-010-16 C-8 C-150
Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
Impact/Vibration resistance Note) 150/50 m/s2 Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal ON and OFF . (Value in the initial stage.)
Pilot pressure range Ambient and fluid temperature (C) 0 to 60 (No freezing) Lubrication Required (Turbine oil, Class 1 lSO VG32 equivalent) VPA3165-06 VPA3145-03 Free Mounting orientation Impact resistance/Vibration resistance (m/s2) Note) 150/50 Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when
1 3 Port Air Operated Valve Series VZA200/400 Specifications SA Fluid Air 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VZA2 2, 2 4 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VA Operating pressure range (MPa) 0.1 to 1.0 0.15 to 1.0 VZA2 2, 2 4 0.1 to 1.0 0.15 to 1.0 SA Pilot pressure range (MPa) Impact/Vibration resistance (m/s2) Note) 150/50 VA Operating pressure Pilot pressure Note) Impact resistance: No malfunction from
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Not required Lubrication Unrestricted Mounting position 150/30 Impact/Vibration resistance (m/s2) (2) Body ported Dustproof Enclosure Note 1) Based on dynamic performance test, JIS B 8374-1981.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Impact/Vibration resistance (m/s2) Note 2) 150/30 Dustproof Enclosure Note 1) Based on dynamic performance test JIS B8374-1981 (Standard type: at coil temperature of 20C, with rated voltage, without surge voltage suppressor) Note 2) Impact resistance:
Push type (Non-locking) Unrestricted 150/50 Shock/Vibration resistance (m/s2) (2) Terminal no. 2 () Manual override Mounting orientation 48 VDC In the case of indicator light assembly Terminal no. 1 (+) 1.1 kg Weight For grommet type Note 1) Based on dynamic performance test JIS B 8374-1981.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150/50 (5) Grommet, DlN terminal VT Standard 100, 200 VAC, 50/60 Hz; 24 VDC 220, 110, 48, and 24 VAC (50/60 Hz) 100, 48, and 12 VDC Coil rated voltage VP Option 15 to 10% of rated voltage Allowable voltage fluctuation Coil insulation type VG Class B or
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil rated voltage Terminal type VT Coil insulation type Class B or equivalent (130C) (3) Shock/Vibration resistance (m/s2) 150/50 (4) VP Note 1) If it is low temperature, dry air should be used.
Mounting orientation Unrestricted 150/50 m/s2 (2) Shock/Vibration resistance Enclosure Dustproof Grommet, Grommet terminal, Conduit terminal, DIN terminal 100, 200, 24 , 48 , 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 6 , 12 , 48 , 100 Allowable voltage fluctuation 15 to +10% of rated voltage 12.7 VA (50 Hz) 10.7 VA (60 Hz) 7.6 VA (50 Hz) 5.4 VA (60 Hz)
Lubrication Manual override Non-locking push type Mounting orientation Unrestricted 150/50 m/s2 Shock/Vibration resistance (2) Dustproof Enclosure Grommet, Conduit, Conduit terminal, DIN terminal 100, 200, 24 , 48 , 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 6 , 12 , 48 , 100 Allowable voltage fluctuation 15 to +10% of rated voltage 19 VA (50 Hz), 16 VA
Lubrication Manual override Shock/Vibration resistance (2) Enclosure Non-locking push type 150/50 m/s2 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.
02 SYA5000 3 position closed center 00 3 1 4 02 With sub-plate 3 8 With sub-plate 3 position exhaust center 03 4 3 position pressure center 5 5-2-3 2 Series SYA3000/5000/7000 Specifications Fluid Operating pressure range MPa Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 (0.7 x P + 0.1) to 0.7P: Operating pressure range 0.1 to 0.7 0.2 to 0.7 Max. 60 Non-locking push type Not required Unrestricted 150
Mounting orientation Free Impact/Vibration resistance (m/s2) (2) 150/50 Note 1) Use turbine oil Class 1 (ISO VG32). Note 2) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal is ON and OFF .
Refer to page 3-13-4.) 3 Required (Turbine oil Class 1 ISO VG32) Yes (Non-locking) Unrestricted 150/50 Silencer for pilot EXH (AN101-01) Operating pressure range (MPa) Ambient and fluid temperature (C) Max. operating frequency (Hz) Lubrication Manual override Mounting orientation Impact/Vibration resistance (m/s2) Accessory (Standard equipment) (1) (2) Note 1) This solenoid valve requires
Fluid 1.0 MPa (0.7 MPa) (3) Maximum operating pressure Valve specifications Solenoid specifications Single 0.20 MPa 0.15 MPa Min. operating pressure Double 0.15 MPa 0.15 MPa 3 position 0.20 MPa 0.15 MPa (1) (1) 5 to 50C 10 to 50C Ambient and fluid temperature Lubrication Not required Plug lead unit Manual override Push type/Locking type (Tool required) Option Shock/Vibration resistance 150
construction Air/Inert gas Fluid (3) 1.0 MPa Maximum operating pressure Plug-in unit Single 0.20 MPa 0.10 MPa Min. operating pressure Valve specifications Solenoid specifications Double 0.15 MPa 0.10 MPa 3 position 0.20 MPa 0.15 MPa 1.5 MPa Proof pressure (1) 5 to 50C Ambient and fluid temperatnre Not required Lubrication Push type/Locking type (Tool required) Option Manual override (2) 150
Impact/Vibration resistance (m/s2) 150/50 Note) Manifold Possible Use dry air (Dew point: 20C or less). If using a lubricant, be sure to use a lubricant for low temperatures.