Set t i ng w hen f act ory i s shi pped 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 7 Pressure set t i ng and out put m oni t ori ng Pressure can be set by sendi ng t he i nput dat a, i n w hi ch F. S. consi st s of 12 bi t s, t o t he E/P regul at or t hrough m ast er PLC( t arget val ue t o w ord area) . Set t i ng D at e 0h 0FFFh [ ( aF.
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom Ported), Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)
Stations: 10 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: N11 (Dia.3/8 One-touch Fitting), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)