SMC Corporation of America
Elite Part Number Search
Search Results "CY1F10L-150"

Lubrication Manual override Non-locking push type Mounting orientation Unrestricted 150/50 m/s2 Shock/Vibration resistance (2) Dustproof Enclosure Grommet, Conduit, Conduit terminal, DIN terminal 100, 200, 24 , 48 , 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 6 , 12 , 48 , 100 Allowable voltage fluctuation 15 to +10% of rated voltage 19 VA (50 Hz), 16 VA

Lubrication Manual override Shock/Vibration resistance (2) Enclosure Non-locking push type 150/50 m/s2 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.

02 SYA5000 3 position closed center 00 3 1 4 02 With sub-plate 3 8 With sub-plate 3 position exhaust center 03 4 3 position pressure center 5 5-2-3 2 Series SYA3000/5000/7000 Specifications Fluid Operating pressure range MPa Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 (0.7 x P + 0.1) to 0.7P: Operating pressure range 0.1 to 0.7 0.2 to 0.7 Max. 60 Non-locking push type Not required Unrestricted 150

Mounting orientation Free Impact/Vibration resistance (m/s2) (2) 150/50 Note 1) Use turbine oil Class 1 (ISO VG32). Note 2) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal is ON and OFF .

Refer to page 3-13-4.) 3 Required (Turbine oil Class 1 ISO VG32) Yes (Non-locking) Unrestricted 150/50 Silencer for pilot EXH (AN101-01) Operating pressure range (MPa) Ambient and fluid temperature (C) Max. operating frequency (Hz) Lubrication Manual override Mounting orientation Impact/Vibration resistance (m/s2) Accessory (Standard equipment) (1) (2) Note 1) This solenoid valve requires

Fluid 1.0 MPa (0.7 MPa) (3) Maximum operating pressure Valve specifications Solenoid specifications Single 0.20 MPa 0.15 MPa Min. operating pressure Double 0.15 MPa 0.15 MPa 3 position 0.20 MPa 0.15 MPa (1) (1) 5 to 50C 10 to 50C Ambient and fluid temperature Lubrication Not required Plug lead unit Manual override Push type/Locking type (Tool required) Option Shock/Vibration resistance 150

construction Air/Inert gas Fluid (3) 1.0 MPa Maximum operating pressure Plug-in unit Single 0.20 MPa 0.10 MPa Min. operating pressure Valve specifications Solenoid specifications Double 0.15 MPa 0.10 MPa 3 position 0.20 MPa 0.15 MPa 1.5 MPa Proof pressure (1) 5 to 50C Ambient and fluid temperatnre Not required Lubrication Push type/Locking type (Tool required) Option Manual override (2) 150

Impact/Vibration resistance (m/s2) 150/50 Note) Manifold Possible Use dry air (Dew point: 20C or less). If using a lubricant, be sure to use a lubricant for low temperatures.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-11 132 300 223 M15 x 1.5 15 151 150 48 25 4-Rc 3/4, 1 3 (R) 40 5-8-12 7 Hand Valve Series VH Dimensions: Panel Mounted VH21-02 VH31-02/03 ( ): Long handle type 4 (B) 2 (A) 25 25 (32) 25 4 (B) SA 1 (P) 3 (R) 1 (P) 74 62 62 49 VA 2 (A) SA 49 4-5.5

1 Silencers/Exhaust Cleaner Series AN/Series AMC Series Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting Series AN00 100 m 150 m Page 5-10-2 30 dB (A) Compact type Space-saving compact type Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588

In addition, the LES series is available in an optional symmetric style *.Reduced tact time - 5,000 mm/s¦ max. acceleration, 400 mm/s max. speed , Positioning repeatability: within ¦0.05 mm , Positioning pattern outputs: 64 points , Compact and space saving , Applicable strokes: 50, 75, 100, 150 ELECTRIC ACTUATOR. HI RIGIDITY ELECTRIC SLIDE TABLE. 0.95000 lb. A34.

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.

Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum operating pressure: 200PSI Operating temperature range: 15 - 150°F Auto switch capable COMPACT CYLINDER. Compact Cylinder, NCQ8. 535.80600 lb. E46.

Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum operating pressure: 200PSI Operating temperature range: 15 - 150°F Auto switch capable COMPACT CYLINDER. Compact Cylinder, NCQ8. 106.87770 lb. E46.

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.

construction Air/Inert gas Fluid (3) 1.0 MPa Maximum operating pressure Plug-in unit Single 0.20 MPa 0.10 MPa Min. operating pressure Valve specifications Solenoid specifications Double 0.15 MPa 0.10 MPa 3 position 0.20 MPa 0.15 MPa 1.5 MPa Proof pressure (1) 5 to 50C Ambient and fluid temperatnre Not required Lubrication Push type/Locking type (Tool required) Option Manual override (2) 150

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.

Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.

A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking CLAMP CYLINDER W/LOCK CLKQ, CLK2.