Coil Specification: Standard, Valve Type: Plug-in Connector Type, Voltage: 5 (24VDC), Connector Entry: C (Dedicated for Centralized Wiring), Light/Surge Voltage Suppressor: U (w/Light Surge Voltage Suppressor, Non-Polar Type), Switch: No Switch, Manual Override: Non-Locking Push Type, Needle Operation: D (Slotted Locking Type), PS Port for Detection: P (With Plug, M-5P)
Coil Specification: Standard, Valve Type: Plug-in Connector Type, Voltage: 5 (24VDC), Connector Entry: C (Dedicated for Centralized Wiring), Light/Surge Voltage Suppressor: Z (w/Light Surge Voltage Suppressor, Polar Type), Switch: J (With Switch), Manual Override: Non-Locking Push Type, Needle Operation: D (Slotted Locking Type), PS Port for Detection: P (With Plug, M-5P)
Coil Specification: Standard, Valve Type: N (Non Plug-in), Voltage: 5 (24VDC), Connector Entry: M (Individual Wiring, w/Lead Wire Length 300mm), Light/Surge Voltage Suppressor: Z (w/Light Surge Voltage Suppressor, Polar Type), Switch: No Switch, Manual Override: Non-Locking Push Type, Needle Operation: D (Slotted Locking Type), PS Port for Detection: P (With Plug, M-5P)
Coil Specification: Standard, Valve Type: N (Non Plug-in), Voltage: 5 (24VDC), Connector Entry: MN (Individual Wiring, w/o Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light Surge Voltage Suppressor, Polar Type), Switch: No Switch, Manual Override: Non-Locking Push Type, Needle Operation: D (Slotted Locking Type), PS Port for Detection: P (With Plug, M-5P)
Coil Specification: Standard, Valve Type: Plug-in Connector Type, Voltage: 5 (24VDC), Connector Entry: C (Dedicated for Centralized Wiring), Light/Surge Voltage Suppressor: Z (w/Light Surge Voltage Suppressor, Polar Type), Switch: No Switch, Manual Override: D (Push-Turn Locking Slotted Type), Needle Operation: D (Slotted Locking Type), PS Port for Detection: P (With Plug, M-5P)
Coil Specification: w/Power Saving Circuit, Continuous Duty Type, Valve Type: Plug-in Connector Type, Voltage: 24VDC, Connector Entry: Dedicated for Centralized Wiring, Light/Surge Voltage Suppressor: w/Light Surge Voltage Suppressor, Polar Type, Switch: No Switch, Manual Override: Push-Turn Locking Slotted Type, Needle Operation: Slotted Locking Type, PS Port for Detection: With Plug, M-
Coil Specification: w/Power Saving Circuit, Continuous Duty Type, Valve Type: Plug-in Connector Type, Voltage: 24VDC, Connector Entry: Dedicated for Centralized Wiring, Light/Surge Voltage Suppressor: w/Light Surge Voltage Suppressor, Polar Type, Switch: No Switch, Manual Override: Non-Locking Push Type, Needle Operation: Slotted Locking Type, PS Port for Detection: With Plug, M-5P
Coil Specification: w/Power Saving Circuit, Continuous Duty Type, Valve Type: Non Plug-in, Voltage: 24VDC, Connector Entry: Individual Wiring, w/Lead Wire Length 300mm, Light/Surge Voltage Suppressor: w/Light Surge Voltage Suppressor, Polar Type, Switch: No Switch, Manual Override: Non-Locking Push Type, Needle Operation: Slotted Locking Type, PS Port for Detection: With Plug, M-5P
Coil Specification: w/Power Saving Circuit, Continuous Duty Type, Valve Type: Non Plug-in, Voltage: 24VDC, Connector Entry: Individual Wiring, w/o Lead Wire, Light/Surge Voltage Suppressor: w/Light Surge Voltage Suppressor, Polar Type, Switch: No Switch, Manual Override: Push-Turn Locking Slotted Type, Needle Operation: Slotted Locking Type, PS Port for Detection: With Plug, M-5P
Stations: 04, System, Port Combinations: Vacuum Pump System, Common PV: ø5/16", Common PS: ø1/4", Inch Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: D [w/Common Release Pressure Supply (PD) Port], Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2 COMPACT CYLINDER, HD, 20MM CQ2 DOUBLE-ACTING, 0.22046 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, CYLINDER, ACTUATOR, CQ2 COMPACT CYLINDER, HD, 20MM CQ2 DOUBLE-ACTING, 0.37085 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2 COMPACT CYLINDER, HD, 20MM CQ2 DOUBLE-ACTING, 0.42549 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2 COMPACT CYLINDER, HD, 20MM CQ2 DOUBLE-ACTING, 0.22046 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2 COMPACT CYLINDER, HC, 20MM CQ2 OTHERS (COMBO), 0.36379 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, CYLINDER, COMPACT CYLINDER
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, CYLINDER, COMPACT CYLINDER