For D-P4DW, 40 to 63 are available. Only D-P4DW type is assembled at the time of shipment. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Since there are other applicable auto switches than listed, refer to page 18 for details.
M10 x 1.25 14 +0.08 0 7.5 2 10 M12 x 1.25 16 11.5 3 14.5 M14 x 1.5 +0.08 0 Trunnion mounting taps for the width across flats NA are not attached to 80 and 100 types. 18 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 A AL B1 C D E F GA GB H H1 I J K KA MM 35 12 26 12 5 M4 x 0.7 depth 7 5 M8 x 1.25 Up to 200 14 13 8 15.5 2 18 12 6 40 12 31 12 6 5.5 M10 x 1.25 M5 x 0.8 depth
Square embedded type pressure gauge Round pressure gauge Panel mount (with set nut) 0.02 to 0.2MPa setting Metal bowl Nylon bowl Metal bowl with level gauge With bowl guard Drain guide Non-relieving type Flow direction: Right to left Drain cock with barb fitting: 6 x 4 nylon tubing B C D E G P 1 2 6 8 C J N R W Z Optional specifications Accessories 1 4 Display units for product name plate
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 7) : For thread type, NPT only.
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.)
Note 6) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.) Note 7) : For thread type, NPT only.
SUS304) 7 11 XL-OMV0017 5-2.Dimensions C E C E E (KF flange) (K flange) Fd Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLF-16-2 40 108 38 20 30 17 44 XLF-25-2 50 121 48 27 12 40 26 44 XLF-40-2 65 171 66 39 11 55 41 67 XLF-50-2 70 185 79 46 11 75 52 72 XLF-63-2 88 212 100 55 11 87 95 70 76 XLF-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMV0017 6.
No.VF1000-OMN0002-A Solenoid Valve PRODUCT NAME VF1000/3000/5000 Series (PILOT VALVE : V200) MODEL/ Series Contents Safety Instructions -2,3 Precautions on Design -4,5 Selection -4,5 Mounting -5 Piping -6 Wiring -6 Lubrication -6 Air Supply -6,7 Operating Environment -7 Maintenance -7 Specific Product Precautions -8 to 12 Trouble shooting -13 Remedy -14 -1No.VF1000-OMN0002-A Safety Instructions
Remove Mount Internal circuit D-M9NJ# D-M9PJ# [Note] Please contact SMC if using AND connection. -11No.D-S-OMS0002-B Maintenance How to reset the product for power loss or forcible de-energizing Regarding set up, contents of the program may be maintained by customer's application systems.
Note3) Vacuum grease is applied to (6)axis seal, (7)scraper, (8)O ring for surface seal and fixed seal.
Air supply 2-5 Piping 2-6. Operating Environment 2-7. Lubrication 3. Maintenance. 3-1. Precautions 3-2 Disassembly Drawing 1 Disassembly Drawing 2 3-3.
Q2 +COM 30.30.4 4 L L 5 DC24V LO L 6 DC12V M M 5 MO M 5 4300 5MMO 6 B 6() 9 - No.ZB-OM00301 / kPa / P1 0-101 15V2F.S.7 P3 -100100 15V2F.S.7 8 EA EAM SI 9 NPN2 EAP [psi] 8 0-101 8 EB EBM SI 9 PNP2 EBP [psi] 8 8 FA FAM SI 9 NPN2 FAP [psi] 8 -100100 8 FB FBM SI 9 PNP2 FBP [psi] 8 73m 8 9kPa G 2m V 10 11 12 C2 2 B C4 4 N1 1/8 N3 5/32 K 12 L2 2 L4 4
R3/8, NPT3/8, G3/8 22 7/8 R1/2, NPT1/2, G1/2 27 1-1/16 (4)For M5, 10-32UNF Tightening method First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a wrench. Refer to the table below for reference values.
No.VP300-OMM0002-A Solenoid Valve PRODUCT NAME VP(A)300/500/700 Series (PILOT VALVE : V200) MODEL/ Series Contents Safety Instructions -2,3 Precautions on Design -4,5 Selection -4,5 Mounting -5 Piping -6 Wiring -6 Lubrication -6 Air Supply -6,7 Operating Environment -7 Maintenance -7 Specific Product Precautions -8 to 12 Trouble shooting -13 Remedy -14 -1No.VP300-OMM0002-A Safety Instructions
(d) 1.6 3 1.6 3 DM6-04N DM6-06N DM6-04NU DM6-06NU DM12-04N DM12-06N DM12-04NU DM12-06NU 5 29 6 31 71
PE Q S T U W MACM2 X114 68 74 76 10 27.4 12 34 X115 52 6 62 X116 50 4 30 46 60 64 22.5 MACM4 X114 86 90 90 72 78 32.5 50 19 32 20 33 X115 56 6 78 40 X116 54 4 40 6.6 12 19 17 18 M5 7 MACM6 X114 118 125 125 97 113 33.8 53 28 33.3 30 43 X115 59 6 98 60 X116 57 4 60 MACM10 X114 185 197 198 11 152 182 18 53.8 77 31 24 13 0 53.3 50 70 X115 83 6 108 X116 81 4 5 Centering Unit MACM Series
ISA2 Note) 5 With LED light (24 VDC, Red) 50 20 to 50 l/min Note) 6 With LED light (24 VDC, Green) IS Note) LED light is available for 5, 6, 7, 8 (with terminal box for 24 VDC).
SMCs?new AF modular style air filter combines the element and bowl in one piece, making element replacement easy.? There is a maximum 46% reduction in size, reducing required maintenance space.? The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360 monitoring.??The modular design of the AF allows connection with other SMC air preparation equipment. The series
Series AL modular style lubricator provides accurate lubrication of downstream equipment. The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment. Atomizes lubricant into fine particles at uniform rate, Drip rate easily monitored with sight dome, Can be refilled under pressure, High-response time