Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: Flow Adj.
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Stations: 05 (5 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: F (G), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: Flow Adj.
Stations: 05 (5 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 08 (8 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Flow direction OUT side IN side 1: Setting is only possible for models with the units selection function. 2: 1 to 5 V or 0 to 10 V can be selected when the analogue voltage output type is used. Analogue output free range function can be selected. 3: When Line name is selected, a suitable line name can be input.
distance IZD10-510 6 From the steepest line, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm of installation distance 5 Sensor output voltage V Installation distance 25mm 4 Installation distance 75mm 3 2 1 0 4 0 3 0 2 0 1 0 0 1 0 2 0 3 0 4 0 Charged potential kV 10 6-2.
In particular, if the voltage rise rate (dv/dt) at zero crossing exceeds 40 V/200 sec, it may cause a malfunction.
Doc. no.CG1-OM0001G PRODUCT NAME STAINLESS STEEL CYLINDER MODEL / Series / Product Number C*G5*N**SR / V-* C*G5*A**SR / V-* Contents Safety Instructions P2 1. Specifications P6 1-1. Specifications 2. Installation and Handling P7 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Cushion 2-7. Control of direction 2-8. Auto switches 3.