Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector or I/O Cable Length for JXC: T (T-branch, for DeviceNetâ„¢ or CC-LInk)
These parameters include Time (T), elapsed time (t), Set Repetitions (N), actual repetitions (n), Set/Reset Priority and more. 24 PneuAlpha How to Use PneuAlpha Series Controllers Getting Started Table 6.2: Function Block Description Table 6.1:Key Number and Basic Operation Others Gives more Options for a Version Check, Password Protection, Summer Time Change Schedule, Modem Initialization
Handle Note Body 1348102#1 ADC POM e Piston assembly Bonnet 1348104A r POM POM, NBR Valve 1348105 t Brass, NBR Valve spring 1348109 y Stainless steel 1348108 (For 0.85 MPa) Steel wire Adjusting spring u 1348108-1 (For 0.3 MPa) Dimensions Panel cutout dimensions 26 R2.5 SUP OUT SMC K C O P A A L U S H 12 37 54 25 1.6 (Max. thickness 4.5) 44 79.5 (When regulating pressure = 82) 5.4 10 31.5
. <> AS1211F-M3 AS1201F-M5 AS1000 AS1002F 2-4. 1. 2. 2. 4. 1. () 2. 5 3. 4. 5 10 2-5 1.
Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: Ø4, Seal Method: S (with Sealant)
Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: E (8mm), Applicable Tubing O.D.: Ø4, Seal Method: S (with Sealant)
Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: Ø6, Seal Method: S (with Sealant)
Body Size: 1 (M5 X 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: M5 (M5 X 0.8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: Ø6, Seal Method: S (with Sealant)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 04 (ø4), Seal: S (w/Sealant)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 06 (ø6), Seal: S (w/Sealant)
While the part number “AS1201F-M5-06A” is indeed viable, “AS1201F-M5-06SA” is not. The “S” is for sealant on the tapered male pipe threads. As the port size of the AS1201F is M5, which is a parallel thread (metric coarse thread), there is no sealant because it uses a gasket seal.
Stations: 5 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 6 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 2 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 1 Station, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 4 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 3 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 12 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 10 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 8 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]