Yellow (Y) Green (G) Translucent (N) (1) Yellow brown (YB) Soft polyurethane tubing Fluid Air 20C 40C 0.6 Max. operating pressure MPa 0.6 Iner sleeve 60C 0.4 One-touch fitting, Insert tube fitting, Miniature fitting (Hose nipple type) (3) Applicable fittings 8 15 15 22 29 Min. bending radius (mm) (2) One-touch fitting 20 to +60C (No freezing) Operating temperature Model Material Tube drawing
ALF ALT Model LMU100 LMU200 Inlet air pressure Oil tank set pressure range Oil Dynamic viscosity of oil (40C) 0.1 to 1.0 MPa 0.05 to 0.2 MPa Turbine oil, Non-water soluble cutting oil (JIS, N1 type) 2 to 200 mm2/s Total capacity: 3000 Effective capacity: 2500 5 to 50C 100 VAC 50/60Hz, 200 VAC 50/60Hz, 24 VDC ALD ALB Oil tank capacity (cm3) Ambient and fluid temperature Solenoid valve voltage
(-40C) Note) Standard purge Low dew point Low dew point Low purge Note) Standard purge rate: 35% Note) Standard purge rate: 20% Note) Standard purge rate: 25% Note) Standard purge rate: 10% IDG1 is not available with standard dew point 15C.
0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 * Shown above are reference values.
H/DL L/LL Soft polyurethane tubing 2 cores X169 (Roll) 3 cores X170 (Roll) 4 cores X171 (Roll) 5 cores X172 (Roll) Fluid Air Max. operating pressure MPa KC Number of cores KK Inner sleeve 20C 0.6 40C 0.6 60C 0.4 Applicable fittings One-touch fitting Note 2), Insert fitting, Miniature fitting (Hose nipple type) Min. bending radius Note 1) (mm) 8 15 15 22 29 Operating temperature 20 to +60C
Symbol L Standard dew point (N) 40 Port size Symbol Bore Size Thread type 30 50 60 75 100 Rc NPT G Nil N F 02 1/4 03 3/8 04 1/2 Standard Specifications/Single Unit Type (Standard dew point: 40C) Model Standard dew point: 40C IDG30L IDG50L IDG60L IDG75L IDG100L Compressed air Fluid Range of operating conditions Standard performance conditions Inlet air pressure (MPa) 0.3 to 1.0 IDG30L
Air Cooled Aftercooler Series HAA HAA HAW Series HAA can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. The air cooled aftercooler does not require cooling equipment and is free from concerns such as water supply cut-off or freezing. Maintenance is easy and the running cost is reasonable.
12.2 4.5 KKH4S-60N 6/9 70.6 20.4 5.4 17 16.5 56.8 60.5 KKH4S-65N 6.5/10 1/4 19 25.4 68.1 24.1 5.9 KKH4S-80N 8/12 69.8 35.1 7.4 19 17.4 55.4 59.1 KKH4S-85N 8.5/12.5 72.4 36.6 7.8 Specifications Fluid Operating pressure range Proof pressure Ambient and fluid temperature Plating, Sealant Sleeve lock mechanism Air, Water (standard industrial water) 0 to 1MPa 1.5MPa Air: 5 to 60C Water: 5 to 40C
*Power supply 100 V type: 35C Power supply 200/230 V type: 40C 2.
. -6- LVP Series Applicable Fluids Material and Fluid Compatibility Check List for Vinyl Chloride Air Operated Valves Chemical Compatibility Material option N Note 2) Temperature 40C or less Ammonium hydroxide Note 1) Note 2) Isobutyl alcohol Temperature 40C or less Note 1) Note 2) Isopropyl alcohol Temperature 40C or less Note 2) Hydrochloric acid Concentration 30% or less Hydrogen
1 Air Cooled Aftercooler Series HAA Model/Standard Specifications Series HAA can cool high temperature compressed air from compressors down to 40C or less and efficiently remove moisture from the air. The air-cooled aftercooler does not require cooling equipment and is free from concerns such as water supply cut-off or freezing. Maintenance is easy and the running cost is reasonable.
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
5 to 40C 5 to 40C 5 to 40C Electric energy 180VA 640VA 300VA 300VA 640VA 100VA 300VA 640VA 640VA 300VA 180VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return function Maximum positioning point setting With magnet switch as adjacent switch, and encoder Z phase signal as home position signal.
(mm) 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 40 20 0 20 40 60 80 100 TS0425 Max. operating pressure MPa Black (B) TS0604 White (W) Red (R) Other than TS0425, TS0604 Blue (BU) Yellow (Y) Green (G) Nominal size (inch) 5 32 " 5 16 " 1 4 " 3 16 " 1 8 " 3 8 " 1 2 " Operating temperature C Nominal size (mm) Specifications Precautions 3.2 Fluid Air/Water Note 1) 20C or less 40C 60C 80C 100C
(mm) 2.5 3 4 4.5 6 7.5 9 13 2.18 3.48 4.57 6.99 9.56 Black (B) Max. operating pressure (MPa) White (W) TIA Series Red (R) Blue (BU) T1613 Yellow (Y) Green (G) T0403 Other metric size Nominal size (inch) 5 32" 5 16" 1 4 3 8 " 3 16" 1 8 " 1 2 " " Nominal size (mm) 0.0 40 20 0 20 40 60 80 100 Specifications 3.2 Operating temperature (C) Fluid Air/Water 20C or less 40C 60C 80C 100C 3.3 2.3 1.65
Operating temperature 32 to 104F (0 to 40C) Material Conductive nylon + Flame resistant nylon (Equivalent to UL-94 Standards V-0) Surface resistance 104 to 107 Hardness Shore D 48 Note 1) Refer to the burst pressure characteristics and operating pressure curve for other temperatures. Avoid abnormal temperature rises due to adiabatic compression.
Features 5 Air Dryer Variations Series IDF E/F/D Standard inlet air temperature type Rated inlet air temperature: 95, 104F (35, 40C) [Max. inlet air temperature: 122F (50C), 140F (60C) (F and FS type only)] Refer to SMC website for details.
FR one-touch fittings: Series KR-W2 Metal one-touch fittings: Series KQB2 Applicable fittings At 20C 0.8 MPa Max. operating pressure At 40C 0.65 MPa How to measure the minimum bending radius At 60C 0.5 MPa Burst pressure Refer to the burst pressure characteristics curve.
IDG60M, IDG100M are fitted with AMH micro mist separator with pre-filter. 1.77 3.53 5.29 Flow Flow Flow 10 25 50 100 200 300 500 600 750 1000 110 170 240 300 100 150 75 50 Single Type 76F (60C) Dew point Single Type 40F (40C) Dew point Single Type 4F (20C) Dew point 3.53 5.29 8.02 11.3 14.12 2.72 5.44 8.29 0.44 1.09 2.19 4.41 8.83 13.24 22.07 25.6 31.78 42.02 Model Inlet Model Inlet Model
Exhaust air throttling or B port pressure reduction possible / / 0.05 to supply pressure Electro-pneumatic HYREG Series VY1 Bracket Pressure gauge Silencer 14-10-1 M5 to 2 Pressure controlled steplessly by electric signals Cylinder thrust control Cylinder thrust control nozzle suction flow control Pressure control of the tank 14-4-3 3 Lubrication Equipment Applicable oil viscosity (cst (40C