(Non-locking) 55.5 [62] 43.1 36.5 25.5 49 A A 19 9.5 21 (Pitch) n-Rc (PT)1/8 P=17 21 (A port) A A 19 9.5 18.5 (Pitch) n-M5 X 0.8 P=16 16 (A port) [ ] for AC Other dimensions are the same as the M5.

10 16 12 8 41 5 30 5 M8 x 1.25 13 26 19 15 M22 x 1.5 1/8 13.5 81 14 136 149.5 25 25 f8 Up to 800 19.5 M10 x 1.25 22 17 10 16 12 16 12 8 46 6 32 5.5 13 28 19 15 M24 x 1.5 1/8 14.5 81 15 142 156.5 32 31 f8 Up to 800 21 M14 x 1.5 24 22 12 16 16 19 12 8 53 8 40 7.5 13 36 19 15 M30 x 1.5 1/8 18.5 87 20 160 178.5 40 34 f8 Up to 800 21 M33 x 2 M16 x 1.5 24 24 12 24 18 21 14 11 54 10 48 7.5 19 44

Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no. NDd9 NDH10 NX R1 U1 Y-J010C 3.30.030 0.060 3.3+0.048 0 3.2 8 10 NTJ-015C 16 8 9.2 M5 x 0.8 4 Y-J016C 50.030 0.060 5+0.048 0 6.5 12 10 * A knuckle pin and retaining rings are included.

T.T. 6 2 x M20 x 1 Lock nut Thickness 6, Width across flats 27 Max. 10 Symbol 2 port 56 (A) 2 23 R port (3 port only) 52 33.5 12 10 1 (P) (108) 3 port (A) 2 22 13 12 10 32 1 (P) 3 (R) 16 * 0.5 MPa supply 2 x 1/4 2 x 5.5 mounting hole 30 25 F .O.F .* 56 N P .T. 3.5 mm O.T. 2 mm T.T. 5.5 mm 40 16 Series VM200 Series VM200 Toggle lever VM220-02-08A VM230-02-08A Panel mounting hole T.T. 6 2

12 113 12.7 127 16 13 133 16.1 204 Required Air Capacity Required air capacity is the volume of air that is required to operate the rotary actuator at a certain speed.

Q + Stroke (NA) Cylinder form 12 16 d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 x 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 x 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 x 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54 9

CY1L15/20/25/32/40 (mm) d B A L JK J HI HG H G FB FA D C Model LD HT HS HP HO HB HA GP EB EA CY1L15 CY1L20 CY1L25 CY1L32 CY1L40 12 9.5 7.5 75 9.5 M6 x 1.0 14 16 40 6.5 6 3 16.6 5 5.6 16 25 39 38 4 6.5 65 13 6 16 9.5 9.5 86 10 M6 x 1.0 16 18 46 8.5 21.6 5.2 5.6 20 31 45 44 10 9 80 16 11 9.5 86 10 M8 x 1.25 21 23 54 8.5 7 4 26.4 6.5 7 20 39 53 52 18 9 90 14 8 20 14 10.5 100 15 M10 x 1.5

Variations Standard stroke (mm) Series Bore size (mm) Cushion 5 10 15 20 25 30 35 40 45 50 75 100 12, 16 20, 25 Rubber cushion CQM 32, 40 50 Compact Cylinder/Guide Rod Type 12, 16, 20, 25, 32, 40, 50 Series CQM How to Order Without auto switch B 20 10 CQM B 20 10 M9B S CDQM With auto switch With auto switch Number of auto switches Mounting Bore size 12 16 20 25 32 40 50 Nil S n 2 pcs. 1 pc

Material MHK2-12 MHKL2-12 MHK2-16 MHKL2-16 MHK2-20 MHKL2-20 MHK2-25 MHKL2-25 !6 !7 !8 !

Flange size XMH Symbol Nil C XMH V V V V XYH V V V Type KF (NW) CF Applicable flange size 16, 25, 40, 50 16 (034), 40 (070) Size 16 25 40 50 XYH Nil KF (NW) 25, 40, 50 3.

Mitsubishi: MELSECNET data link system (2 power supply systems) OMRON: SYSBUS wire system Sharp: Satellite I/O link system NKE: Simplified wiring system (16 point output) Sanks: S-LINK system (16 point output) Sanks: S-LINK system (8 point output) Fuji Electric: T link mini system S 2 to 9 (12) 1 station U side n DeviceNet, OMRON Compo Bus/D (2 power supply systems) OMRON: Compo Bus/S (16

(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.

bytes) Increase and decrease by 16 points. 128 points/ 16 bytes Available b) Input size 0 to 128 points (0 to 16 bytes) Increase and decrease by 16 points. 128 points/ 16 bytes Available c) Output size Slave unit setting The valve output size is included in the output size of each station.

I-020B I-032B I-040B E1 L1 MM H A1 MM +0.058 0 +0.058 0 +0.070 0 0.1 0.2 0.1 0.2 0.1 0.3 +0.058 0 +0.058 0 +0.070 0 0.1 0.2 0.1 0.2 0.1 0.3 9 14 10 16 20 36 M8 X 1.25 9 9 10 14 18 46 66 41 9 M8 X 1.25 M10 X 1.25 9 14 10 18 20 38 9 9 10 14 22 48 69 45 9 M10 X 1.25 M14 X 1.5 15.5 16 20 14 22 24 55 12 16 20 24 69 92 50 12 M14 X 1.5 Double Knuckle Joint (mm) Bore size 20 25/32 40 A L NX2 R2 U2

Q+Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 X 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 X 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 X 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54

13 31 9 3 10 83 46 101 91 1/8 40 14 65 63 14 27 to 1000 35 27 11 65 120.5 46.5 20 14 38.5 9 2 12 100 52 120 104.5 1/4 50 15.5 77 75 18 32 to 1000 35 27 11 75 134.5 56.5 20 14 39.5 9 2 12 115 62 135 119.5 1/4 63 16.5 92 90 18 32 to 1000 40 32 13 95 169 72 25 20 45.5 12 4 16 126 63 153 150 1/4 80 19 100 102 22 37 to 1000 40 41 16 114 189 89 30 20 54 14 4 16 150 75 178 170 1/4 100 19 120 116

H G I J K L A B C D E F M R Size Tolerance +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 +0.027 0 +0.027 0 +0.027 0 +0.027 0 9 9 16 16 36 38 55 55 16 18 22 22 9 9 12 12 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 12 30 30

point branch I/O unit Unit with e-con combines branch unit with 16 point unit. 16 point I/O unit 16 point unit with e-con allows common models used for both I/O units. 8 point I/O unit 8 point unit with e-con allows common models used for both I/O units.

Electrical entry VQ2000 N3: 5/32" N7: 1/4" N9: 5/16" NM: Mixed Top entry Side entry Stations Note1) Kit Flat cable kit (20P) without cable JU0 JS0 2 to 8 (16) J kit G0 (VQ1000) GU0 (VQ2000) Flat cable kit (20P) with terminal block without cable G kit 2 to 8 (16) Note 1) Numbers inside ( ) indicate the maximum number of solenoids for mixed single/double wiring.

Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.