Content of diagnosis 0 There is an error in unit 0. 1 There is an error in unit 1. 2 There is an error in unit 2. 3 There is an error in unit 3. 4 There is an error in unit 4. 5 There is an error in unit 5. 6 There is an error in unit 6. 7 There is an error in unit 7. Unit diagnosis byte1 Bit No.
Content of diagnosis 0 There is an error in unit 0. 1 There is an error in unit 1. 2 There is an error in unit 2. 3 There is an error in unit 3. 4 There is an error in unit 4. 5 There is an error in unit 5. 6 There is an error in unit 6. 7 There is an error in unit 7. Unit diagnosis byte1 Bit No.
(Note 4)The F .S. means the condition at the maximum setting pressure of the product. (F .S. 0.2MPa, IR3000) (Note 5) Repeatability: This is the reproducibility of the downstream pressure at every operation (ON/OFF) on the downstream side.
Base mounted with screws With the base mounted type fixed with screws, confirm the installation of the gasket mounted on the body interface and fasten the dedicated mounting screws (AXT632-106-1) at an appropriate torque (0.10 to 0.14 Nm). (Fasten equally so that the valve will not tilt.) After tightening by hand, tighten an additional 1/4 rotation for M3 and 1/6 rotation for M5.
Base mounted with screws With the base mounted type fixed with screws, confirm the installation of the gasket mounted on the body interface and fasten the dedicated mounting screws (AXT632-106-1) at an appropriate torque (0.10 to 0.14 Nm). (Fasten equally so that the valve will not tilt.) After tightening by hand, tighten an additional 1/4 rotation for M3 and 1/6 rotation for M5.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1. The product is provided for use in manufacturing industries.
Maximum speed (mm/s) VQ4000 (36.0) Tubing I.D.
How to order I Z S 3 0 7 8 0 S B I Z S 3 0 D 1 I Z S 3 0 C S I Z S 3 0 B E I Z S 3 0 N T Ionizer Bracket Product name I Z S 3 0 Bar type Ionizer B Mounted Not mounted For "mounted", two brackets for body end are attached. Number of attached bracket for body middle part is by the bar length.
MHC2-10D JIS Symbol Double acting How to Order D 20 MHC2 Y59A S Number of auto switches Single acting Angular style air gripper 2 pcs. 1 pc. S Nil Bore size 10 mm 10 Action Auto switch Single acting S 16 mm 16 20 mm 20 25 mm 25 Double acting D Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.
MHC2-10D JIS Symbol Double acting How to Order D 20 MHC2 Y59A S Number of auto switches Single acting Angular style air gripper 2 pcs. 1 pc. S Nil Bore size 10 mm 10 Action Auto switch Single acting S 16 mm 16 20 mm 20 25 mm 25 Double acting D Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.
MI W S + 0.05 0.02 CEP1 CE1 CE2 ML2B C J G5-S
Bore size (mm) Piano wire u Return spring CUJB4-S-PS 4 Sintered metallic BC i Bronze element CUJB6-S-PS 6 Set of nos. above !1 and an exclusive grease pack. o Magnet CUJB8-S-PS 8 Steel Nickel plated !0 Rod end nut CUJB10-S-PS 10 NBR !1 Piston seal NBR !2 Rod seal NBR !
(Note 4)The F .S. means the condition at the maximum setting pressure of the product. (F .S. 0.2MPa, IR2000) (Note 5) Repeatability: This is the reproducibility of the downstream pressure at every operation (ON/OFF) on the downstream side.
(Note4) The F .S. means the condition at the maximum setting pressure of the product. (F .S. 0.2MPa, IR1000) (Note 5) Repeatability: This is the reproducibility of the downstream pressure at every operation (ON/OFF) on the downstream side.
(Note 4)The F .S. means the condition at the maximum setting pressure of the product. (F .S. 0.8MPa, IR2120) (Note 5) Repeatability: This is the reproducibility of the downstream pressure at every operation (ON/OFF) on the downstream side.
Especially when using a 3-position exhaust center valve or a single acting cylinder, take appropriate measures to prevent malfunction by using it with an individual EXH spacer assembly, a back pressure check valve, or an individual exhaust manifold. Doing so may cause human injury and/or an accident.. 14.
The programmed Key(s) will give an output signal for as long as the key is depressed.
Note) In the case of body options S and L, the materials of the part nos. e and r are as follows: (Example): VN1-A3BA However all brackets of valve element VNB 1 to 4 are made of stainless steel. (No need to add options S and L.)
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 1) The valve has been lubricated for life by the factory 3. Take measures to ensure air quality, and does not require any further. such as by installing an aftercooler, air dryer, or water separator.