Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from CCW to CW. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) 32 - Origin offset The origin offset means the value of the origin.
An example of when the SI unit station number is set to 01 is shown below.
M3 M5 01 N01 R04 R06 IM5 IM5H M5 female M5 female Port size M3x0.5 M5x0.8 R1/8 NPT1/8 M5x0.8 4 6 thread, thread, through M5x0.8 reducer reducer through type (with type mounting hole) Case Resin case: PBT Fitting: C3604BD PBT Resin case: PBT Resin case: PBT Fitting: SUS303 Fitting: A6063S-T5 Material Pressure sensing section Pressure sensor: Silicon, O-ring: NBR Oil resistance vinyl cabtyre
Front protective cover ZS-27-01 -7No.SFOD-OMO0004-B Summary of Product parts Names of individual parts Output (OUT1) display (Green): Lit when OUT1 is ON. Output (OUT2) display (Red): Lit when OUT2 is ON. LCD display: Displays the current status of charged potential, set mode condition and error code.
How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.
Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).
Description Materials Bonnet Aluminum die-cast Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply diaphragm Weather resistant NBR Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, stainless steel, HNBR Body Aluminum die-cast Grease: lithium grease -7- How to order IR 0 0 01 BG A 0 1
Rated pressure range A B ZSE3 0 to -101 kPa 0 -101 kPa ISE3L 0 to 98 kPa 0 98 kPa ISE3 0 to 0.98 MPa 0 0.98 MPa -25No.PS-OMO0002-A Dimensions Grommet type Z/ISE3-01/T1-26No.PS-OMO0002-A Connector type Z/ISE3-01/T1-C -27No.PS-OMO0002-A Single-installation type Grommet type ZSE3-0X-28No.PS-OMO0002-A ZSE3-0X--D -29No.PS-OMO0002-A Connector type ZSE3-0X-C -30No.PS-OMO0002-A ZSE3-0X-C-D -31No.PS-OMO0002
Address setting range is 01 to 99. Setting at the time of shipment is 01. 1 9 0 9 0 1 2 2 8 8 7 3 7 3 6 4 6 4 5 5 8 - Setting the terminator Set PROFIBUS communication line terminator. With Terminator (at shipping) Without terminator Without terminator When the product is connected to the terminal of PROFIBUS communication line, be sure to set it to with terminator.
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 (CCW) to 1(CW). Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -24-
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the starting point return is changed from CCW to CW. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) 32 - 5. Wiring of cables / Common precautions Warning 1.
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 to 1. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -28-
Useable range 10 10 Load Work piece Useable range 5 5 Fn 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 7 8 9 1 01 11 21 31 41 5 Lo Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B40 CY3B20 Selection example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the cylinder shaft center to the load application point of Lo =
Inch size Metric size 3.2 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 With One-touch fittings Use 1/8" tube. 15-9-72 2 Speed Controller with One-touch Fittings Panel Mount Type, In-line Type Needle Valve/Flow Characteristics AS1001F AS2001F AS2051F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR))
Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10 2 Speed Controller with One-touch Fittings In-line Type Series AS Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5
588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series Option VQZ 2 VQC2000 Nil None All stations with back pressure check valve Note 1) Manifold model B D D VQD 1 Plug-in unit With DIN rail (Rail length: Standard) With DIN rail (Rail length: Special) Note 2) Stations Special wiring specifications Note 3) (Except double wiring) With name plate External pilot Note 4) 01
Kit (Connector Kit) How to Order Manifold C W VV5Q 5 5 08 03 Series Option 5 VQ5000 Option None Exhaust cleaner for Rc 1: D side exhaust Exhaust cleaner for Rc 1 1/2: D side exhaust Exhaust cleaner for Rc 1: U side exhaust Exhaust cleaner for Rc 1 1/2: U side exhaust Symbol Nil CD1 CD2 CU1 CU2 SB SD SU W Manifold Note) 5 Plug lead unit Note) Kit type Note) C Stations kit (Connector) Note) 01
D. 9 to 11:P368010-27 View A 100 46 30 2 14 IP8000-01 (With terminal box) OUT2.Rc1/4 With plug 110 38 192 218 23.5 110 40 35 OUT1.Rc1/4 SUP.Rc1/4 2 x M8 x 1.25 depth12 (Female thread for side mounting) 43 23.5 58 38 39 11 9 39 OUT2 MPa 42 162 117 16 6.1 MPa 20 50 65 A 122 ELECTORO PNEUMATIC IP8000 P O S I T I O N E R 22.5 125 At accessory E: 110 At accessory F: 110 { } 5 150 125 12 168 8
5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS1000 How to Order 01 VFS1 1 20 1 G Symbol Option 2 position single F: With foot bracket Thread type 1 Nil N Rc NPT NPTF G T Port size 01 F Rc 1 8 2 position double SJ Option 2 Mountable only for VFS1120.
Stations Port location R16 Arrangement (Right valve station which is looked from valve side is first station.) 01 1 Left side Right side R L B 06 6 Refer to (About individual spacer.)