Hz) 1 2 3 Symbol Port size Thread type Symbol Sub-plate A B 1/8 1/4 Nil Rc G NPT NPTF F N T 4 5 6 7 Base gasket VEX1 11 2 9 Other Option Body size Port size Electrical entry (Only with solenoid) Port size Body size Electrical entry Port 1(P), 2(A) 3(R) 01 1 02 1 8 1 8 G Grommet (Lead wire length 300 mm) 1 4 1 4 H Grommet (Lead wire length 600 mm) 02 3 03 1 4 1 4 D DIN terminal 3 8 3 8 DO
If the product is bent to less than the minimum bending radius, the moisture control tube will be Do not use the product in conditions of compressed air or an environment containing solvents. Recommended equipment coupling after inserting the sleeve again before the fitting is installed when if it slips off. not come out.
Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Manifolds SJ2000/3000, S0700 series : Refer to the catalogues and operation manuals for details on the solenoid valves and manifolds. How to mount the manifold 1.
No.6 No.5 No.8 No.7 No.10 No.9 Red flashing Wrong switch setting, Parameter writing error Green On Bus-off state, Duplicate MAC ID 16 32 4 8 1 2 Red flashing Off Green On I/O Connection is in the Timed-Out state Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Bit: 7 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bit No. 6 4 6 4 2 0 0 0 Solenoid on side A 0 2 4 6 8 16 28 30 Output No.
Do not connect multiple NFC readers / writers to a PC. Connection details using the I/O Configurator for NFC and wireless unit To use a wireless system, it is necessary to "pair" a Wireless Base and Remote. Configure this using the I/O Configurator (NFC version).
Non-locking push type Unrestricted 150/50 m/s2 Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port).
Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Pull the pressure regulator knob to unlock. (You can visually verify this with the "orange mark" that appears in the gap.) Push the pressure regulator knob to lock.
Do nol loosen the recessed head screw on the top of the sensitivity adiusting screw because ii is lor prelenting the screw trom slipping otf. @
If operating pressure is over the range then cylinder will be damaged and injury by broken pieces. (4) Do not put your hand into the slit of the body without confirming safety. Injury and Bodily harm will occur with the valve operated when valve is operated valve. (5) Do not remove the Cover Fig.1 29 on the actuating part.
Do not apply pressure to this hole. Attach tubing to the vent hole and place the end of the tubing so it is not exposed to dust or water. For the rod end male thread, refer to page 247.
Do not reuse if disassembled. High strength adhesive is applied to the portion of the connection that is threaded to prevent it from loosening, and it must not be disassembled.
Do not scratch or gouge the sliding portion of the piston rod. Damaged seals, etc., will result in leakage or malfunction. 4. Do not dent or scratch the mounting surface of the body and the plate. The flatness of the mounting surface may not be maintained, which would cause an increase in sliding resistance. 5.
Identifying Version Symbols For versions lower than V2.0 and S2.0: Do not use with controller parameters higher than V2.0 or S2.0. Applicable models Applicable models JXC91m Series JXCD1m Series JXCP1m Series JXCE1m Series For versions higher than V2.0 and S2.0: Do not use with controller parameters lower than V2.0 or S2.0.
Customers do not need to apply for a license to use this equipment. Be sure to comply with the following precautions. Do not disassemble or modify the product. Disassembly and modification are prohibited by law.
Do not use in locations where there is splashing or spraying of oils and solvents. Since this unit is open type, if water or oil, etc. make an ingress etc., the internal circuit may be corroded and result in a malfunction or damage. 2. Ground the piping when induction noise is expected to be generated from piping.
Do not use in locations where there is splashing or spraying of oils and solvents. Since this unit is open type, if water or oil, etc. make an ingress etc., the internal circuit may be corroded and result in a malfunction or damage. 2. Ground the piping when induction noise is expected to be generated from piping.
Do not use these for pneumatic operations because they will lead to oil leaks. Air-hydro cylinder: CA1HCQ2HCS1HCM2HCG1H(up to 63) HC03-X1x Air-hydro rotary actuator: CRA1H2.
For the auto switch mounting rail, do not remove the pre-equipped rail. Since the mounting thread is drilled through inside a the cylinder, it will result in air leakage. MVGQ For basic style, the port position in a head cover is available either perpendicular to the axis or in-line with the cylinder axis.
Do not immerse the cylinder in water or chemicals. When the cylinder is operated in a condition with water pressure, the fluid leaks into the cylinder in the early stages. In the worst case, the fluid may back flow inside the piping and damage the solenoid valve. Maintenance Warning Mounting 1.