Magnet: D (Built-in), Mounting: X (MP1, Double Rear Clevis), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)
Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
TU0425 TU0604 TU0805 TU1065 TU1208 TIUB01 TIUB05 TIUB07 TIUB11 TIUB13 Color 100 m reel Black, White, Red, 200 m reel X3 Blue, Yellow, Green, 400 m reel Clear, Orange 500 m reel X4 20 m roll Red, White, Yellow, Green, Clear, Orange 373 Soft Polyurethane Tubing Series TUS Suitable for piping in confined spaces Extremely flexible Soft polyurethane tubing Model/Specifications 20 m roll
M&I 400 software. 0.00000 lb. H25.
Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor: 400 W, Maximum speed: 1000 mm/s, Dust/Drip proof specification *, RoHS compliant ELECTRIC ACTUATOR. ROD TYPE ELECTRIC ACTUATOR. 5.84000 lb. A38.
Distance between Z and Z1 axis mm Inertia moment around the Z1 axis of A part of attachment kgm2 Z2 Distance between Z and Z2 axis mm Inertia moment around the Z2 axis of B part of attachment kgm2 Allowable Range of Moment of Inertia of Attachment MHY2-10D MHW2-20D MHW2-50D 1.2 6 600 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 500 1.0 4 400
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor: 400 W, Maximum speed: 1000 mm/s, Dust/Drip proof specification *, RoHS compliant ELECTRIC ACTUATOR. ROD TYPE ELECTRIC ACTUATOR. 17.61600 lb. A38.
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: M (Applicable to Deionized Water Piping)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, with Rc-G Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K