SMC Corporation of America
Elite Part Number Search
Search Results "ISE71-N02-L2-S"

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -

ASD330F-N01-05ST ASD330F-N01-07ST ASD330F-N01-09ST ASD430F-N02-07ST ASD430F-N02-09ST ASD430F-N02-11ST ASD530F-N02-07ST ASD530F-N02-09ST ASD530F-N02-11ST ASD530F-N03-07ST ASD530F-N03-09ST ASD530F-N03-11ST ASD630F-N04-11ST 8.4 9.3 11.4 12 11.6 13.2 15.2 13.2 15.2 18.5 13.2 15.2 18.5 13.2 15.2 18.5 18.5 12.9 17.5 29.4 10-32 UNF 7.8 27.4 0.7 31 30.7 11.7 4.5 10 9.6 8 16.5 13.5 16.5 17 18.5 17

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring

The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. These high performance, yet lightweight, pressure controls are available in three styles: the ISE70 for use with air or inert and incombustible gases (monitoring a set rated pressure range between –0.1 to 1MPa), and the ISE75 and ISE75H models (for use with fluids requiring

Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric

Where finite adjustment is required to control actuators at very low speeds such as handling fragile material or smooth process control, the in.-FMin. series has been designed exclusively to meet this requirement. Effective orifice area has been reduced to 1/10th of standard series, but still retains 10 turns of the adjustment needle, (20 turns on the M5 size). This series comes complete

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, MBRANE W/SEPARATOR, OTHERS, IDG 1/4 MEMBRANE AIR DRYER, 1.82983 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air temperature

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, MBRANE W/SEPARATOR, OTHERS, IDG 1/4 MEMBRANE AIR DRYER, 2.42508 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air temperature

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, MBRANE W/SEPARATOR, OTHERS, IDG 1/4 MEMBRANE AIR DRYER, 1.716 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air temperature

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, MBRANE W/SEPARATOR, OTHERS, IDG 1/4 MEMBRANE AIR DRYER, 1.99698 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air temperature

L2 Applicable tubing Weight (g) Model Applicable tubing O.D. 6 8 10 12 D L1 L2 Q W M AQ 0.2 KEA06 KEA08 KEA10 KEA12 12.8 15.2 18.5 20.9 24 27 29 31 21 23 26.5 28.5 5.3 6 6.8 7.5 13 15.4 18.7 21.1 17 18.5 21 22 10 15 22.5 29.5 ASV 0.05 MPa 0.1 0.05 AK 10 8 7 6 4 2 0 With One-touch fitting with a push button guard: KEB Release time S Release time of pressure in the cylinder Body (Red) Residual

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)

ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)