(C) (A) (A) (C) (A) (C) BLEED SUP OUT SU P N/ M Pa/ ( S) N N m 1 1 M Pa/m ( ) m 2 M Pa M Pa (A) /N (B) / ( ) m 2 ( A ) m 2 5- I R 3 0 0 1 SUP OUT 2 3%F.S. 3 R B(P36203018) G 2 3 RcF N IR3000G43-2-01 G43-P2-N01-X30 IR3010G43-4-01 G43-P4-N01-X30 IR3020G43-10-01 G43-P10-N01-X30 02:1/4 03:3/8 04:1/2 Rc FG NNPT 00.010.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG
ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer
* flange: MQR8-F (for MQRF8-M5) * flange: MQR12-F (for MQRF12-M5) * o 55 * o 45 * o 41 * o 50 * 4-4.5 mounting hole * 4-8 counter bore 5.5 4.5 mounting hole +0.05 4.1 depth10 54h8 24 x M5 x 0.8 10 counter bore depth1.5 30h8 (10 from end) 49h8 0 -0.033 25h8 16-M5 x 0.8 10 counter bore depth1.5 0 0.033 3 120 140 17 *7 (10 from end) 3 (87) 1 2 3 4 5 6 7 8 9 10 11 12 1 2 31 9 8.2 x 11 = 90.2
Target position: 100.000[mm] (=10 [m] = 186A0h) Target speed: 100[r/min] (=10 [0.01r/min] = 2710h) Acceleration time constant: 100 [ms] (= 64h) Deceleration time constant: 100 [ms] (= 64h) The setup value is as follows.
(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8
-00 Fax: 01-64-76-10-10 South America Argentina Phone: 011-4555-5762 Fax: 011-4555-5762 ?
C D E F G H J K L AS100P-04-04 AS200P-04-04 AS200P-06-06 AS250P-06-06 AS300P-08-08 AS300P-10-10 23.9 31.4 31.3 33.6 37 37.5 41.7 51.4 52.3 54.6 60.5 63.5 26.7 36.4 36.3 38.6 42 42.5 38.9 46.4 47.3 49.6 55.5 58.5 26 30 30 32 36 39 9.3 9.3 11.6 12.8 15.2 18.5 17 17.1 18 18 19 22 4 4 6 6 8 10 4 4 6 6 8 10 10 13.6 13.6 17 22 22 12.7 12.7 13.5 16.8 18.5 21 17.4 18.9 19.9 24.1 27 30.5 22.4 25.7
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be 3% or less of the rated voltage. 6.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214
model Bore size (mm) 40 32 25 20 D-B7/B80 D-B73C/B80C D-C7/C80 D-C73C/C80C D-B5/B64 8 10 9 10 8 10 9 10 8 13 8 10 13 10 9 14 9 10 14 10 D-B59W D-G79/K79/K79C D-H7BAL D-H7/H7W/H7NF 4 4 4.5 5 7 8.5 9 10 D-H7C D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 45 D-G59F D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
Note 3) For wear ring A of 10, please consult with SMC. Seal kit includes a grease pack (6, 10: 5 and 10 g, 15 to 63: 10 g). Order with the following part number when only the grease pack is needed. Grease pack part no. for 6, 10: GR-F-005 (5 g) for external sliding sections GR-S-010 (10 g) for tubing interior Grease pack part no. for 15 to 63: GR-S-010 (10 g) 112
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 Although speed adjustment is possible with
model Bore size (mm) 40 32 25 20 D-B7/B80 D-B73C/B80C D-C7/C80 D-C73C/C80C D-B5/B64 8 10 9 10 8 10 9 10 8 13 8 10 13 10 9 14 9 10 14 10 D-B59W D-G79/K79/K79C D-H7BAL D-H7/H7W/H7NF 4 4 4.5 5 7 8.5 9 10 D-H7C D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 45 D-G59F D-G5NBL 5 35 5 40 5.5 40 Since this is a guideline including hysteresis, not meant to be guaranteed.
6 1000 20 5 100 30 4 10 50 6 1000 5 5 100 15 4 10 30 6 1000 20 5 100 50 4 10 60 6 1000 10 5 100 40 4 10 50 6 1000 50 5 100 80 4 10 100 LEFS16 500 500 LEFS25 900 500 Please aspirate it from the port on both sides when aspirating 50 /min(ANR).
20 20 Power supply 100-240 VAC 100-240 VAC 24 VDC 100-240 VAC 24 VDC + 10% 15 % + 10% 15% + 20% 15% + 10% 15% + 20% 15% 50/60 Hz 50/60 Hz 50/60 Hz Maximum micro power cut 10ms 10ms 5ms 10ms 5ms Maximum inrush current 0.7A 1.5A 0.7A 1.5A 7A 0.7A 1.5A 7A Maximum power 3W 4W 3W 8W 6W consumption ANALOGUE INPUT CHARACTERISTICS AC INPUT CHARACTERISTICS 10 6 inputs from I01 to I06 Input voltage
16.9 20 10 2 190 22.8 50 10 18.8 20 10 3 190 24.4 47 10 20.4 15 10 7 190 28.7 31 10 24.7 15 10 Operating range m: The value in which the auto switch operating range Lm is converted to axis rotating value.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC