T1 (Terminal block of 1 row): 1-4 stations T2 (Terminal block of 2 rows): 5-8 stations T1 and T2 can be optionally chosen by adopting the combinations of single and double wiring(option spec.)etc.

T1 (Terminal block of 1 row): 1-4 stations T2 (Terminal block of 2 rows): 5-8 stations T1 and T2 can be optionally chosen by adopting the combinations of single and double wiring (option spec.) etc. The quantity of terminal blocks used depends on the number of manifold stations Double wiring (connected to SOL. A and SOL.

Brake lever Brake piston Locking spring Brake cylinder Auto switch for lock unit Unit: mm 125 140 160 180 200 250 Bore size (mm) Manual release bolt Screw depth M6 x 1.0 x 35l M6 x 1.0 x 40l M8 x 1.25 x 40l M10 x 1.5 x 50l M10 x 1.5 x 55l M12 x 1.75 x 70l 30 32 35 40.5 45 55 Eccentric cam shaft In case the manual release bolt is not available, use an appropriate hexagon socket head bolt

Temperature characteristics 12 to 24 VDC (Ripple 10% or less) Operating voltage 17 mA or less at 24 VDC, 2 output: 25 mA or less at 24 VDC Current consumption 8 1 8 1 01: R / , M5 x 0.8 T1: NPTF / , M5 x 0.8 00: ZM ejector mounted style Port size 0 to 60C (No condensation) Operating temperature range For details, refer to Best Pneumatics Vol. 16.

-02 Performance/Specifications General specifications LC5-1-T1-02 Part no.

D C D D M5 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 125L x 150L M5 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 125L x 150L M6 x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 105L x 110L x 135L x 160L x 185L x 210L M8 x 75L x 80L x 85L x 90L x 95L x 100L x 105L x 110L x 115L x 120L x 145L x 170L x 195L x 220L x 245L C Model Mounting bolt C Model

Caution (1) Do not connect to equipment other than specified (LEC-W1, LEC-W2, LEC-T1, LEC-G).

T2 V W T1 S 6.5 10 18 50 80 11 YB-03 32, 40 Part No.

each other. 4 3/16" Double acting 2 Material 6 1/4" Actuator section Applicable option Diaphragm PTFE Body type Symbol Note Body 6 1/4" End plate PPS 1 4 A Stacking type for manifold Nil PFA 3 8 Hydrofluoric acid compatible (Only LVC40, 50 type) PTFE F PVDF PFA 10 3/8" Ammonium hydroxide compatible 10 3/8" PTFE N PPS PFA 4 12 1/2" Pilot port thread type Symbol Thread type M5 Rc 1/8 NP T1

Bore size (mm) T1 T2 V W RS Weight (g) Part no.

Option Note1) Communication cable Actuator cable Part No: -LE-C*-*-* (Robotic type cable) -LE-C*-*S-* To CN4 Conversion unit To CN3 Controller setting soft ware (Standard cable) To CN2 Note2) Controller power supply 24VDC To CN1 or PC USB cable Power supply plug (A-miniB type) AWG20 (0.5mm2) Controller setting kit Teaching box (with a cable of 3m long) Part No: LEC-T1

-25 NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ZSE401 T1-26 Vacuum Analog output 1~5V (+ 5%F.S.), load impedance : 1k ZSE401 T1-65 PNP output PNP open collector 80mA ISE4L01 T1-25 Positive Pressure NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ISE4L01 T1-26 100kPa Analog output 1~5V (+ 5%F.S.), load impedance: 1k ISE4L01 T1-65 (14.5PSI) Type

bar absolute, T1 = 297 5K, 0.07 bar P 0.14 bar.

Caution Do not connect to equipment other than specified (LEC-W1, LEC-W2, LEC-T1). When connected to equipment which is not specified, the product will be damaged by incorrect signal wiring. When connecting the cable, make sure that no electrically conductive materials are present in the connector insertion port. In the LEC-W1, the 0V of the driver and PC is not insulated.

If using the rod end nut with a single knuckle joint or a double knuckle joint, use the type with rod end bracket ("XC86) or refer to page t1. .: ~'For tHe ~1:iEkificiitiQns of Cylinders with auto switch, please refer to pages 21 to 24.

i|3"T1)"Hil3: Yl g SpinS 12.16 ; -"; -r+or_+..--..;i 5 (N)co2 NorHotating rcd Also Available: se/ies End 125 Sinqle 140 ^l".l _4']OaE ^-^; 180 t lrz 2CO LargE bore size !

Power supply 11) 100/110V AC (50/60Hz) 200/220V AC (50/60Hz) 21) 1) Consult SMC if the supply voltage for LC1-1HV1 will be 110V AC or more, or the supply voltage for LC1-1HV2 will be 220V AC or more. or LC1-1-T1(Teaching box) are required.

.-' PRO225M Metric *Notei 41 and t1 apply to urethane slfiker cap accessory. (tr) fiox. Shorl lor.e (ll) l{omirol (oil Spring lorre (Iol l{lox. Propelling lorre (l{} ftlolog l{0. Eote Sire lnn) (sl Slroke {mn) (tr) n!x. llln/tvrle) (trq Iox, (l{n/ho!

P: Pressure drop between static pressure output ports [bar] P1 : Pressure at ustream output port [bar gauge] P2 P2= 1 P Q : Flow rate [dm3/s standard atmosphere] Pa : Atmospheric pressure [bar absolute] T1 : Upstream absolute temperature [K] Test conditions are P1+Pa=6.50.2 bar absolute, T1=2975K, 0.07barP0.14 bar. the pressure drop is so small compared with the upstream pressure that air

Part No:LEC-T1-3EG Note 2): When conformity to UL is required, the electric actuator and controller should be used with a UL1310 Class2 power supply. Part No:LEC-W2 Warning Refer to the operation manual of the LEC (controller) for detailed wiring. / See 4 Wiring of cables on p.32. Communication cable is to be connected to PC by USB cable through conversion unit.