Refer to P.18 for assembling method. M8 8 Pin connector (Plug) NPN output PIN No.
(The SI unit type is provided for use in Japan.) + Voltage AC/DC 48 V 100 V Nil S None With seal w w Seal 50 mA 40 mA 20 mA Max. operating current and range Note 2) + Nil 6 Note1) Set pressure range 0.1 to 0.4 MPa 0.1 to 0.6 MPa a Semi-standard + Nil L Z 0.5 m 3 m 5 m Lead wire length q e b Series IS10 + Scale plate pressure unit MPa Both MPa and psi Nil P Note2) c CAT.ES60-19A
(HRS050-A-20-(BJMTW)) 9.5.2 HRS040-W-20-(BJMTW) 1500 1500 Facility water temperature Facility water temperature 1200 1200 Heating capacity[W] Heating capacity[W] 40 40 900 900 32 32 25 25 600 600 20 20 5 5 300 300 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60H 50H Fig. 9-6 Heating capacity(HRS050-W-20-(BJMTW)) HRS Series
X2709 2 B 02 30 R B AW Body size Flow direction Nil Flow direction: Left to right R Flow direction: Right to left 30 Body size 30 40 Body size 40 60 Body size 60 Bowl Port size 2 Metal bowl Symbol Port size Body size 30 40 60 02 Rc1/4 V V 03 Rc3/8 V V 04 Rc1/2 V 06 Rc3/4 V V 10 Rc1 V Mounting option1 Nil Without mounting option B2 With bracket H3 With set nut (for panel mount) Waterproof
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 OR-1400-178P P: PTFE F: FKM OR-2670-178P P: PTFE F: FKM For VCS30, 40 OR-1717-178P When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .
20-HRSH090-W-4014 Facility water temperature: 32 oC 12 Cooling capacity [kW] Facility water temperature: 40 oC 10 8 6 4 2 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [] Fig. 9-7 Cooling capacity(HRSH090-W-20-HRSH090-W-40-) HRSH Series 9.4 Cooling capacity 9-11 HRX-OM-R026 Chapter 9 Documents Pump capacity 9.4.4 HRSH090-A-20/40-HRSH090-W-20/400.6 60 Circulating fluid pressure [MPa
Y W Z E Applicable voltage: 12 and 24 VDC Since the indicator light is built in the connector, thus, DOZ is not available.
JXC-OMU0029-A 2.3 How to Order The part number construction for this product is as follows: Controller Controller Electric actuator model Compatible Example: For LEHZ10LK2-4AF-R11N1, P Step motor (Servo / 24 VDC) specify LEHZ10LK2-4.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 2 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: -, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: -, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -100 to 100 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: -, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: -, Option 2: -, Option 3: -, X Options: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
-_'_fJ EI I n V i I m-] lh-rn-ru | 'rl-| #--.lf7l,{! 'rll-r-1 q-___l__rL iJrql_:^-f^/rF+l -Ti-e),ri-?-'J I u c o u p n s / / p e a f l n s Con lnc I F'rolection Box Conlact Protection,,/lnternal Circuit O-R7 and D-Rg type switches have no built-in contact omtection circuit. Use this box for induction loads, 1.5 ft (0.5m) or more of lead wire, or AC 100V aoolications. 9q-q1!
P. 4 KJH P. 6 KJT P. 8 KJU Different diameter straight Union tee Different diameter plug-in Y Use to branch line with size down in the same direction from One-touch fittings. Use to connect different sized tubes. Use to connect tubes in both 90 directions. P. 5 KJH P. 8 KJX P. 7 KJT Male elbow Different diameter tee Branch Y Use to pipe at right angles to female thread.
Load voltage Electrical entry Lead wire length (m) Auto switch model Electrical entry Indicator light Wiring (Output) Pre-wire connector Special function Applicable load In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Type Perpendicular 3-wire (NPN) 3-wire (PNP) Y59A Y69A IC circuit 5 V 12 V Y7P Y7PV Solid state switch 12 V Y59B Y69B 2-wire Relay, PLC Grommet Yes 24 V 3-wire (NPN) 3-wire (PNP) Y7NW
(Default settings) Solenoid Specifications Electrical entry DIN terminal (D) DIN terminal (Y)