Do not inadvertently move the guide adjusting unit. The guide is installed at the proper tightening torque. Do not loosen the mounting bolts of the guide. 2. Do not operate the magnetic rodless cylinder if the magnet couplings on the actuator are displaced.
Do not operate with the magnetic coupling out of position. If the magnetic coupling is out of position, push the external slider by hand (or the piston slider with air pressure) back to the proper position at the stroke end.
Caution Do not apply a load that is 50% or more of the theoretical output.
As an air slide table has magnets built-in, do not allow close contact with magnetic disks, magnetic cards or magnetic tapes. Data may be erased. 4. When mounting an air slide table, use screws with appropriate length and do not exceed the maximum tightening torque. Tightening with a torque above the limit could malfunction.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Specifications x100 IP address x 10 1 DIP SW Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Technical documentation giving detailed configuration information and the GSD file can be found on the SMC website (URL http://www.smcworld.com). Specifications Do not operate in an atmosphere containing flammable or explosive gases.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Connect valve manifold to the SI unit. Refer to the EX260 series valve manifold section in the valve catalogue for valve manifold dimensions. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the handle assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the handle assembly itself. Do not disassemble the parts that are not explained in this operation manual.
Do not use it for an application in which rotation or oscillation is applied. (2) Use a foot type or flange type bracket to mount a cylinder. If a clevis type or trunnion type bracket is used, the cylinder shaft will not be fixed and it will be able to rotate.
Handling notes 6.1 Cautions for handling of the vertical auto switch unit (1) Be sure to connect a load to the switch before turning the power supply on. (2) Do not let objects drop onto or dent the product or subject it to strong impact when handling. (3) Do not use the product in the presence of a strong magnetic field. (4) When using two or more cylinders with auto switches closely in
Precautions Do not turn off the controller for communication while the setting software (ACT Controller) is running. Do not connect or disconnect the cable while the setting software is running. The communication is continuously established while the setting software is running.
Do not disassemble, except for when replacing any of the replaceable parts, as this may cause the performance to deteriorate. (8) Proximity switch output The switch output signal is output near the clamping end and the unclamping end respectively.
Do not apply excessive force or impact. This may damage the product, as well as, decrease its performance and life expectancy. Do not disassemble the parts that are not explained in this operation manual. This may decrease the performance and life expectancy of these parts. In addition, disassembly may cause danger. Torque values specified in this manual must be followed.
If the compressed air includes ozone, do not use it since it may damage the product or cause malfunction. When it includes ozone, use a clean gas filter (SFA/B/C). 1. The material of the element is polycarbonate.
. * Do not indicate symbol N for no lead wire on D-A3lA, A44A, G39A and K39A .
Do not use these for pneumatic operations because they will lead to oil leaks.
11H9 Depth 1.5 35 Positioning pin hole MHZ2 47.5 9 MHZJ2 58 15 MHQ Auto switch mounting groove position M5 X 0.8 (Finger opening port) MHL2 MHR 3 O 13 MHK S MHS 3 4 23 7 M5 X 0.8 (Finger closing port) 2 MHC2 MHT2 MHY2-10D2 Opening/closing direction through hole type 43.4 MHY2 (Hole for mounting attachment) MHW2 6 0.005 0.025 3 6 MRHQ 12 Auto switch (Limited area for mounting attachment) Do
Do not use these for pneumatic operations because they will lead to oil leaks. Air-hydro cylinder: CA1HCQ2HCS1HCM2HCG1H(up to 63) HC03-X1x Air-hydro rotary actuator: CRA1H2.