D-A93 D-M9B D-M9N, D-M9P Type Load voltage Load current range Indicator light Application Reed auto switch Solid state auto switch 24 VDC, 100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA, 5 to 20 mA 2.5 to 40 mA 40 mA or less Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors
D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation
D-Z73 D-Y59B D-Y59A Load voltage 24 VDC,100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less Load current range Indicator light Application Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC 5 to 40 mA, 5 to 20 mA 5 to 40 mA 40 mA or less PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.
voltage drop 2.4 V or less (to 20 mA) / 3 V or less (40 mA) F: D-sub connector (9P) Indicator light Red light emitting diode (LED) lights up when ON.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-P Attachment mounting thread 4-FD through Supply port PD NA FF FE PC PA A Mounting threads 4-MA thread depth MB Groove position for auto switch mounting HB depth HC HD (2 pcs.)
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field
Find the allowable static moment Ma (Nm). 2 = 0.23/9.14 = 0.025 Find the load factor 2 of the static moment. 2 = M/Ma 3-3 Load factor of dynamic moment Pitching Examine Mep. (30 + 17) Mep = 1/3 x 8.4 x 9.8 x = 1.3 1000 We = 4/100 x 0.5 x 420 = 8.4 A2 = 17 Meap = 1 x 0.7 x 9.14 = 6.40 K = 1 = 0.7 Mpmax = 9.14 3 = 1.3/6.40 = 0.20 (Ln + An) Me = 1/3 We x 9.8 1000 Find the dynamic moment Me
or less Switch output 1 output (NPN or PNP) Maximum load current 10 mA Maximum applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short circuit protection Provided Repeatability 0.005 mm 0.010 mm 0.020 mm Temperature characteristics (Reference: 25C) 0.010 mm 0.015 mm 0.030 mm Hysteresis 0 to variable (Default: 3) 0 to variable (Default: 20) Display 2-screen display, LCD Main
ON voltage 11 to 30 V OFF voltage 3 to 5 V Internal current consumption 50 mA or less Weight 280 g 1 An M12 (4-pin) connector can also be connected.
Maximum allowable load current is 80 mA. Be sure to not exceed 80 mA. 1. Mounting orientation is available either horizontally or vertically. 2. Be sure to hold the main body when handling. 3. Do not drop or strike body. Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads.
Note 7) Purchase an earth leakage breaker with current sensitivity of 15 mA or 30 mA/power supply 100 VAC separately. Note 8) Dimensions between panels, not including the dimensions of protrusion. Note 9) Weight in the dry state without circulating fluids.
(Do not use this product with continuous voltage fluctuations.) *1 Select an earth leakage breaker with a leak current sensitivity of 30 mA. Regarding the rated current, refer to the Applicable Earth Leakage Breaker Capacity.
p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.
p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.
p10%50 mA or lessIP650 to 50C (with no freezing and condensation)Operation, Storage: 35 to 85% R.H.
80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?
80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?
80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?
80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?
80 kPa4 to 20 mA DC, 0 to 20 mA DC0 to 5 VDC, 0 to 10 VDC4 points (Negative common)250 or less Note 3)Approximately 6.5 k Power supply voltage 24 VDC type: Approximately 4.7 k Power supply voltage 12 VDC type: Approximately 2.0 k 1 to 5 VDC (Load impedance: 1 k or more)4 to 20 mA DC (Sink type) (Load impedance: 250 or less)Output accuracy within ?