Size: 4 (1/2 Basis), Thread: Rc (Metric thread, M3, M5), Port Size: 04 (1/2), Option: L [Low Temperature (-30 to 60°C)]
Size: 5 (3/4 Basis), Thread: Rc (Metric thread, M3, M5), Port Size: 04 (1/2), Option: L [Low Temperature (-30 to 60°C)]
Size: 42 (1/2 Basis), Thread: Rc, Port Size: 04 (1/2), Option: L [Low Temperature (-30 to 60°C)]
Rated Flow Range: 5 to 500 L/min, Thread Type: Rc, Port Size: 1/2, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: -, Unit Specification: -, Option 2: -, Calibration Certificate: -
Size: 1/2 Basis, Thread: Rc, Port Size: 1/2, Option: L [Low Temperature (-30 to 60°C)]
Series: AF, Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Mounting: Standard, Float Type Auto Drain: w/o Auto Drain, Bowl Type: Standard (Polycarbonate Bowl ), Bowl Guard: None, Drain Port: w/Drain Cock, Indicator: L (with Element Service Indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: W (Drain Cock w/Barb Fitting), Pressure Unit: Pressure Unit: MPa; Temp Unit: °C
Model: LVH40 (Body Class 4, N.C.), Lever Operation: L (Locking), Port Size: 04 (1/2), Pilot Port Thread: N (NPT), Material: A (Body: SUS, Actuator Section: PP, Diaphragm: PTFE)
Flow Rate Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Valve: None; Stop Valve: None, Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2), Mounting: w/o Mounting Option, Float Type Auto Drain: D [N.O. (Normally Open)], Bowl: 2 (Metal Bowl), Drain Port: w/Drain Cock, Indicator: L (w/Element Service indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z (Name Plate and Caution Plate for Bowl in Imperial Units: psi, °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: J (OUT 1: Analog 1 to 5V; OUT 2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (
Size: 75, Standard Dew Point: L (-40°C), Type: A, Thread: N (NPT), Port Size: 04 (1/2), Accessory: None (Standard), Option: PR (Fitting for Purge Air Exhaust/Flow Right to Left)
Size: 40, Thread Type: N (NPT), Port Size: 04 (1/2), Mounting: w/o Mounting Option, Float Type Auto Drain: D [N.O. (Normally Open)], Bowl: 2 (Metal Bowl), Drain Port: w/Drain Cock, Indicator: L (w/Element Service Indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z (Name Plate and Caution Plate for Bowl in Imperial Units: psi, °F)
Type: L (Elbow), Direction: B (Horizontal), Applicable Tubing O.D.: 04 (ø4), Residual Pressure Release Function: without Residual Pressure, Thread Type: Rc, Size: M5 (M5 x 0.8)
Body Size: 40, Thread Type: Rc, Port Size: 04 (1/2), Mounting: B (w/Bracket), Float Type Auto Drain: D [N.O.
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: E (Out 1: PNP; Out 2: Analog 1 to 5 V), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: W (w/Lead Wire w/Connecter + Connector Cover), Unit Specifications: M (SI Unit Only), Option 2: Without Bracket, Calibration Certificate: A (With Calibration Certificate)
Stations: 04 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: KW (with Unit Options K & W), 1st Nominal Nozzle Size:
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.