Then with one side fixed, gradually close the other side and measure 2R at the point where the tubing folds or flattens, etc. 2R Fixed side How to Order Burst pressure drop curve 1.0 TL0604 Metric sizes 20 Burst pressure drop coefficient 0.8 TIL01 20 Inch sizes 0.6 Length Applicable to both metric and inch size 0.4 Tubing Model Symbol 10 20 50 100 Type Length 10 m 0.2 20 m Roll 50 m 0 20

How to Replace the Solenoid Coil Caution Replacement Parts Solenoid coil part number Clip VCW 20 1 G Series Lead wire length Flat head screw driver 20 30 40 Class 2 Class 3 Class 4 300mm 600mm 1000mm 1500mm 3000mm Nil L1 L2 L3 L4 Solenoid coil Voltage Insert a flat head screw driver into the hook section of the clip groove. 1 2 3 4 5 6 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC Electrical entry

Then with one side fixed, gradually close the other side and measure 2R at the point where the tubing folds or flattens, etc. 2R Fixed side How to Order Burst pressure drop curve 1.0 TL0604 Metric sizes 20 Burst pressure drop coefficient 0.8 TIL01 20 Inch sizes 0.6 Length Applicable to both metric and inch size 0.4 Tubing Model Symbol 10 20 50 100 Type Length 10 m 0.2 20 m Roll 50 m 0 20

A water resistant type cylinder is recommended for use in an environment which requires water resistance. However, please contact SMC for water-resistant products of 20 and 25. 2 1 m type lead wire is only applicable to D-A93.

HEC-OM-S008 First edition Aug.2014 Rev1.2 May.2017 C Co om mm mu un ni ic ca at ti io on n M Ma an nu ua al l THERMO-CON Model No. HECR series Keep available whenever necessary.

Excessive torque or holding it at an area other than the specified portion may result in a malfunction. 2. While piping to products or operating the handle, ensure that an excess bending moment should not be applied to a product, because it may result in damage.

Temperature 45.30 38.30 8-5/8 2 18 215 AFW1400-N30FGM-E* 1,400 48.20 38.40 10.80 3 18 326 4 AFW2100-N40FGM-E* 2,100 50.30 39.30 12.80 4 20 439 AFW2800-N60FGM-E* 2,800 6 50.30 39.30 12.80 5 20 439 AFW3500-N60FGM-E* 3,500 54.30 40.40 14 6 20 536 AFW4200-N60FGM-E* 4,200 E D EL-AFW700-E* 55.10 40.60 16 8 24 647 AFW5600-N80FGM-E* 5,600 232 psi 32 8 250F 58.10 40.60 18 10 28 778 AFW7000-N80FGM-E

If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident. : : : : : : : : : : Direct mounting (1)When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1

Mounting and Installation Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes). 1.0 to 1.2 Yellow ZS-28-C-1 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

Tightening the threaded portion of an M3, M5 or M6 fittings 1) M3 First, tighten it by hand, then give it an additional 1/4 turn with a wrench. 2) M5 and M6 First, tighten it by hand, then give it an additional 1/6 turn with a wrench. Mounting Caution 1. Check tubing for damage before installing. Confirm model size, etc. 2.

Absolutely never use in an atmosphere where explosive gases are used. The compact manometer does not have explosion proof construction. If used in an atmosphere of explosive gases, there is a possibility of causing an explosion, and therefore, should absolutely not be used under these conditions. 1. The compact manometer can be used for measurement of air and non-corrosive gases.

Absolutely never use in an atmosphere where explosive gases are used. The compact manometer does not have explosion proof construction. If used in an atmosphere of explosive gases, there is a possibility of causing an explosion, and therefore, should absolutely not be used under these conditions. 1. The compact manometer can be used for measurement of air and non-corrosive gases.

It is possible to avoid discoloration by installing a super mist separator which absorbs vaporized oil and an odor removal filter. It is recommended to add the super mist separator and an odor removal filter after replacing the dew point indicator. Table 3-1.

It is possible to avoid discoloration by installing a super mist separator which absorbs vaporized oil and an odor removal filter. It is recommended to add the super mist separator and an odor removal filter after replacing the dew point indicator. Table 3-1.

Option Setting Set the optional function in accordance with steps 19 to 20 below. (19) Click Option to display the Option Setting screen. (20) The Option Setting screen is displayed. Items that are checked will function. Uncheck unnecessary items. The setting can be reset by clicking the Default button. 8.

The response behavior of an electropneumatic proportional valve is affected by the load capacity. Therefore, select an electro-pneumatic proportional valve in accordance with the bore and the stroke of the cylinder to be used. (The diagram below is provided as a guide.)

Our pressure switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling. Although the body of the sensor may not be damaged, the internal parts of the sensor could be damaged and lead to a malfunction. 2.

Install an air filter (the AF series) as a preliminary filter on the inlet side of the mist separator regulator to prevent premature clogging. 2. Install an air filter (the AFM series) as a preliminary filter on the inlet side of the micro mist separator regulator to prevent premature clogging. Mounting and Adjustment Warning 1.

Install an air filter (the AF series) as a preliminary filter on the inlet side of the mist separator regulator to prevent premature clogging. 2. Install an air filter (the AFM series) as a preliminary filter on the inlet side of the micro mist separator regulator to prevent premature clogging. Mounting and Adjustment Warning 1.