Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation
Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Main Body Shape: Unit, Additional Function: Silencers, Ultimate Vacuum(kPa): -88, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: Rc1/8, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø6, Application: Individual Item, Operating Pressure Range(MPa): 0.45~0.6, Operating Temperature Range(°C): 5:50~, Suction Flow(l/min)
Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size, CYLINDER, COMPACT CYLINDER, 541, 46 lb
MUFFLER, 1/16"PT, SILENCER AN 2500, 2501, 153, 4.6 lb
ONE TOUCH FITTING 4MM STRAIGHT, PRESSURE SWITCH, ISE1-6, N59, 5 lb
ONE TOUCH FITTING 4MM ELBOW, PRESSURE SWITCH, ISE1-6, N59, 5 lb
ONE TOUCH FITTING 6MM STRAIGHT, PRESSURE SWITCH, ISE1-6, N59, 5 lb
ONE TOUCH FITTING 6MM ELBOW, PRESSURE SWITCH, ISE1-6, N59, 5 lb
The SYJA3000/5000/7000 series are 4 and 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3
The SYJA3000/5000/7000 series are 4 and 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3
The SYJA3000/5000/7000 series are 4 and 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3
The SYJA3000/5000/7000 series are 4 & 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3 MFLD
The SYJA3000/5000/7000 series are 4 and 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3
The SYJA3000/5000/7000 series are 4 and 5 port air operated valves with rubber seals. The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, BASE MT, SYJ3000 SERIES, VALVE, SS5YJ3 MFLD SYJ3000, UJ, SS5YJ3 BUILT IN FITTING 0.35273 lb