AMX-OMZ0094 PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AMD50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AMD60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1.
L A B C Series Lead 5(2.86) (Including pulley 20 10 5 20 10 5 (Pulley ratio 4/7) ratio) Parameter *1,*2 Para.
Seat material Material Code Material PCTFE (Standard) Vespel 2) No code VS Code Body material 316L SS secondary remelt Hastelloy C-22 S H 2) Not available with H material.
Reference condition for volumetric flow: 101.3 kPa, 20 C, 65%RH The flow measurement which is converted at normal atmospheric pressure conditions at 20 C, 65%R.H. Standard condition (ANR) An output type that has only 2 conditions, ON or OFF. In the ON condition an indicator LED will turn on, and any connected load will be powered.
AMX-OMZ0093 PRODUCT NAME Mist Separator MODEL / Series / Product Number AM50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AM60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AM50 10 6-2.
B L2 1 = W/Wmax = 1/7 = 0.14 L3 C 2. Static moment Mr = W x 9.8 (L3 + C) Examine Mr. (Mp, My values do not apply to this example.)
Bore size(mm) Auto switch model 20 50 40 32 25 D-M9(V) D-M9W(V) D-A9(V) Note 1) Note 1) Note 1) Note 1) Note 1) BMA3-020 BMA3-025 BMA3-032 BMA3-040 BMA3-050 (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) Note 2) D-M9A(V) BMA3-020S BMA3-025S BMA3-032S BMA3-040S BMA3-050S (A set of b,c,d,e) (A set of b,c,d,e) (A set of b,c,d,e) (A set of b,c,d
AMX-OMZ0092 PRODUCT NAME Line Filter MODEL / Series / Product Number AFF50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AFF60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AFF50 10 6-2.
Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Cushion 2-7. Directional control 2-8. Auto switch 3. Maintenance P17 3-1. Checks 3-2. Replacement of seals 3-3. Consumable parts 3-4. Troubleshooting 4. Basic Circuit for Clamp Cylinder Operation P23 5.
R T XA H VA VB 3 U X PW 6 Section XX details XAH9 depth 6 S Q GC GA GB 2 x P PB XAH9 depth 6 2 x P (Plug) G J K b a PA + Stroke E FB FA e c d A + Stroke B + Stroke C + Stroke T-slot dimensions [mm] [mm] Bore size [mm] a b c d e Bore size [mm] f f 12 3.3 5.8 2.6 1.6 4.8 16 3.7 6.2 3 2.5 6.5 20 5.4 8.4 4.5 2.8 7.8 25 5.4 8.4 4.5 3 8.2 12 7 16 2.5 20 8.5 25 6 50 mm stroke or less Top-ported
D-C7/C80 50 50 + 45 (n 2) 10 15 15 + 45 ( n 2) (n = 2, 4, 6) 2 D-H7/H7W D-H7NF D60 + 45 (n 2) 60 15 10 D-C73C/C80C D-H7C 15 + 50 ( n 2) (n = 2, 4, 6) -X 2 65 + 50 (n 2) 65 15 10 4. One-touch fitting cannot be replaced. One-touch fitting is press-fit into the cover, thus cannot be replaced.
T U AT O R THIS SERIES, PLEASE REFER TO CAT:N350 SWITCH MOUNTING CLAMP ASSEMBLY FLANGE MOUNTING ASSEMBLY Model Part No Model Part No NCDRB1BW10 P211170-1 NC_R1FW10 P211170-2 NCDRB1BW15 P211190-1 NC_R1FW15 P211190-2 NCDRB1BW20 P211160-1 NC_R1FW20 P211160-2 M O R E D I M E N S I O N S S E E N E X T P A G E NCDRB1BW30 P211180-1 NC_R1FW30 P211180-2 M O R E A C C E S S O R I E S S E E N E X T
Note 1) At rated voltage Note 2) Plug-in should be ZNR 3-3-68 5 Port Solenoid Valve Base Mounted Series VZ5000 (2) Flow Characteristics/Weight Flow characteristics (1) Port size Valve model Type of actuation Weight (g) 1 4/2 (P A/B) 4, 2 (A, B) 1, 5, 3 (P , EA, EB) 4/2 5/3 (A/B EA/EB) C [dm3/(sbar)] Grommet 200(120) 240(160) C [dm3/(sbar)] Cv b Cv b Single Double Closed center Exhaust
Block mounting screw 2 Chrome steel/Nickel plated 2 2 2 2 Chrome steel/Nickel plated 2 2 2 2 Screw for mounting rail Chrome steel/Nickel plated 2 2 2 2 Switch mounting screw 2 Carbon steel/Nickel plated 2 2 2 2 2 Hexagon nut 2 2 2 Hexagon socket head plug Chrome steel/Nickel plated Note 1) mark indicates strokes.
Block mounting screw 2 Chrome steel/Nickel plated 2 2 2 2 Chrome steel/Nickel plated 2 2 2 2 Screw for mounting rail Chrome steel/Nickel plated 2 2 2 2 Switch mounting screw 2 Carbon steel/Nickel plated 2 2 2 2 2 Hexagon nut 2 2 2 Hexagon socket head plug Chrome steel/Nickel plated Note 1) mark indicates strokes.
MHL2-16D MHL2-16D1 MHL2-16D2 SMHL, #2 SMHL2A, #3 SMHL2A, #4 (#4+#5) 2.2-8 Series MHL2 Dimensions MHL2-20Dl 10 10 11 2-M6 X 1 Thread depth 7 (Mounting thread) D Closed J A cross view (Fingers closed) C B A 4H9 +0 030 0 Depth 4 2-6.6 (Body mounting hole) 52 6.45 5 5 4-M6 X 1 Thread depth 12 (Mounting thread) 5 4H9 +0 030 0 Depth 4 Dimensions of auto switch mounting groove (Enlarged view) 27H9
(Double rod type: 2 pcs.) Snap ring Type C 8 for axis Type C 10 for axis Type C 10 for axis Type C 14 for axis m 1.5 1.25 1.25 1.75 t 0.9 1.15 1.15 1.15 Part no.
(Double rod type: 2 pcs.) Snap ring Type C 8 for axis Type C 10 for axis Type C 10 for axis Type C 14 for axis m 1.5 1.25 1.25 1.75 t 0.9 1.15 1.15 1.15 Part no.
IO-Link port No. 0 1 1 2 2 3 3 4 Precautions for handling Be sure to fit a seal cap on any unused connectors. Proper use of the seal cap enables the enclosure to achieve IP67 specification. -16No.EX-OMY0026 LED display The LED displays the status of Pin No.4 (C/Q) and Pin No.2 (I/Q or P24) of each IO-Link port of the SI unit. The figures below show the status of each port.
Insulation resistance Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) Atmospheric pressure Operation:80 kPa to 108 kPa (under 2000m) Storage: 66 kPa to 108 kPa (under 3500m) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z EN 60068-2-6 Vibration