SMC Corporation of America
Elite Part Number Search
Search Results "AWD40-N04DG-Z-D"

BBA1: D-A5/A6/F5/J5 D-F5BAL switch is set on the cylinder with the screws above when shipped. When a switch only is shipped, BBA1 screw is attached.

Option Bore size (mm) Description 6 Bore size (mm) Bracket 6 Symbol Specifications 10 16 10 16 XA Change of rod end style XB6 Heat resistant cylinder (150C) Auto switch D-A9(V), D-M9(V), D-M9W(V) Flange CP-F006A CP-F010A CP-F016A XB7 Cold resistant cylinder Foot Single knuckle joint CP-L006A CP-L010A CP-L016A I-P006A I-P010A I-P016A XC22 Fluororubber seals Trunnion (with pin) CP-T006A CP-T010A

VDW Option Enter together in order, counting from station 1 on the D side. 20 20 stations None DIN rail mounting DIN rail mounting (Without DIN rail) Nil D DO VQ VX2 U side D side Stations321 VX VX3 VXA A port VN P1 LVC How to Order Valves (For Manifold) LVA VQ M C6 2 1 1 1 G LVH Series/ Orifice size LVD Port size Symbol 2 3 Series VQ20 VQ30 LVQ VQ20 VQ30 Symbol C6 C8 C10 C12 Port size

(For band mounting, only the auto switch mounting brackets are assembled before shipment.) * When mounting a band on bore size 8, 10, or 12, the D-A9l(V) cannot be mounted. * When mounting a rail on bore size 8, 10, or 12, the D-A9l(V) and A79W cannot be mounted. * When mounting a rail on bore size 20 or 25, the D-M9l(V), M9lW(V), and M9lA(V) cannot be mounted. 2 C85 Series Specications Bore

Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked "" are produced upon receipt of order. Do not indicate lead wire length symbol N (none) for types D-A3, D-A44, D-G-39 or D-K39.

Smooth Cylinder Series CQSY 12, 16, 20, 25 How to Order B 20 D 30 C CQSY M9BW B D 20 30 C CDQSY With auto switch Number of auto switches Nil S n With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.

PSE Z I SE3 5 V Output voltage F PS F.S. F.S. is the abbreviation for Full Span or Full Scale. The maximum fluctuation width. EX.)

Components Function 1 PROFINET connection (BUS OUT) PROFINET connection for Port 2 M12 4-pin socket, D-coded 2 PROFINET connection (BUS IN) PROFINET connection for Port 1 M12 4-pin socket, D-coded 3 Power supply connection Power supply for valves and power supply for logic of the SI unit M12 4-pin plug, A-coded 4 FE terminal Functional earth terminal M3 screw 5 Output connector Output connection

Min. to Max. a to b c to d PF3W7 oC Common 0 to 100 -10 to 110 0 to 1000 -100 to 1100 : The flow ranges and relationship between the fluid and PD are shown in the figures below.

Dec Z Qz RZ SZ . ZZ AZ BZ . Apr R QR RR SR . ZR AR BR . Jul U QU RU SU . ZU AU BU . Month Q R S . Z A B . Oct X QX RX SX . ZX AX BX . T With stand for vertical installation 8 1 15 9 D-sub 15 pin (Socket type) Fixed screw: M2.6 Description No.

ON/OFF / / 2 3 3 2 1 2 / -20- 3.3. [] LEC LEC / P.32 5.3 <> NPNPNP LEFS16A-100 NPN <> INPIN []INP ON ON INP ON OFF -21- <> No.1 01 a b c d e f g h i j k a ABSINC No. 1 2 mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 ABS 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 ABS 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 ABS()/ / INC()// b c d e f 00 g h i 100%DC24V 250% j 12

D eodori zat i on m ay det eri orat e i f w at er drop i s cont ai ned i n com pressed ai r. N o back f l ow Pl ace w here ai r f l ow s backw ards I N El em ent O ri ng G asket ( N ew ) ( N ew ) O ver rat ed f l ow Year 2008 2009 2010 2021 M ont h J an Feb M ar D ec SYM BO L M N o Z SYM BO L o P Q Z I nst al l vert i cal l y. Fl ush i nsi de of pi pi ngs w i t h ai r.

Push-turn slotted locking type [Type D] While pressing, turn in the direction of the arrow. If it is not turned, it can be operated the same way as the non-locking type. Locked position When operating the locking type D with a screw driver, turn it gently using a watchmakers screw driver.

VQZ Model Weight Weight (g) VFN200N/Flow Characteristics VZ Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN212N-5D-02F 240 380 VS C 2.68 2.68 b 0.40 0.40 Cv 0.72 0.72 C 5.41 5.41 b 0.31 0.31 Cv 1.38 1.38 VFN212N-5D-02F-D 2 position Single solenoid VFN Double solenoid How to Order VFN212 5 D N 02 F Z NAMUR Interface Solenoid Voltage Nil D Single solenoid Double solenoid Thread

I ll lir r i I l l l + r EtacK ^^ DC Lamp, Surge Voltage Supffessor Circuit z *"o",.ioffiJl-l|= *-ilEll-l'" EZ, TZ, DZ EZ, rZ, DZ {1@V or more) (Less tban 24V) Electrical Connection Use As A 3 Port Valve a For the DIN connection and Terminal connection (with surge voltage protection circuit), inner connections are as follows.

Rod end thread Male thread Female thread Long male rod end Nil F G Cushion CG1 Mounting Auto switch mounting bracket Note) N Rubber bumper B L F G D Basic Foot Rod flange Head flange Clevis Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.)

ISO Standard Hydraulic Cylinder 40, 50, 63, 80, 100 CHSD Series 10 MPa CHQ How to Order CHK 100 M9BW CH D SD B 40 CHN Magnet for auto switch Number of auto switches Series type CHM Nil D Without Nil S n 2 pcs. Built-in Symbol D Nominal pressure CHS CHS 1 pc. 10 MPa "n" pcs.

Band mounting style is not available for D-A9V/M9V/M9WV and D-M9A(V)L types. D-A79W cannot be mounted on bore size 10 cylinder with air cushion. Lead wire length symbols: 0.5 m 1 m 3 m 5 m None Solid state auto switches marked with are produced upon receipt of order. D-A9/M9/M9W/A7/A80/F7/J7 auto switches are shipped together (not assembled).

1 Multistage Ejector ZL112A Series 1 DC type only RoHS How to Order ZL112A Without valve M Z D A M L ZL112A K1 5 With valve q t o u i w e r y !0 !1 !