Cap bolt Bore size (mm) Hole: CD H10 d9 A B CD CL CT CU CW 112.5 82.5 10 102.5 5 14 20 32 10 6 14 22 124 92 114 40 14 7 20 28 134.5 96.5 124.5 50 146 102 14 132 8 20 30 63 CU Bore size (mm) L B + Full stroke RR CW CX+0.2 +0.4 CX CZ RR CL + Full stroke CZ -0.3 -0.1 18 36 10 32 A + Full stroke 18 36 10 40 22 44 14 50 22 44 14 63 10 Series RZQ Auto Switches Proper Mounting Position(For Detection
Auto switch proper mounting position (mm) D-M9 D-Z7/Z80 Auto switch D-M9V D-Y59/Y7P D-M9W D-Y69/Y7PV model D-A9(V) D-P3DWA D-P3DW D-P4DW D-M9WV D-Y7W D-M9A D-Y7WV D-M9AV D-Y7BA Bore A B A B A B A B A B A B size (mm) 20 9.5 12.5 5.5 8.5 4.5 7.5 25 9.5 13 5.5 9 4.5 8 6 8.5 1.5 5 32 10.5 12 6.5 8 5.5 7 6 7.5 2.5 4 5 6.5 40 14.5 14.5 10.5 10.5 9.5 9.5 10 10 6.5 6.5 9 9 50 12.5 16.5 8.5 12.5 7.5
) + b (2) Conversion formula from the flow gauge measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Flow range Inclination a Intercept b 1 L 0.00025 0 2 L 0.0005 0 5 L 0.00125 0 L/min 10 L 0.0025 0
B A is displayed for 1 V (or 4 mA). B is displayed for 5 V (or 20 mA). The range can be set as required. Display Select NPN or PNP A NPN PNP Voltage input 1 V 5 V Current input 4 mA 20 mA Analog output of 0 to 10 V is also available.
(Displays 0 when the value is below 10 L/min.)
C Y Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B B F E F F E A H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581
I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's
Hs B 30 MLGP Auto Switch Proper Mounting Position (mm) ML1C Auto switch model D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL D-Z7/Z80 D-Y5/Y6 D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F D-A59W D-F5NTL Bore size (mm) A A A B A B A B A B B A B B 125 140 160 180 200 4 4 8 8 1.5 1.5 0 0 2 2 4.5 4.5 9.5 9.5 4 4 8 8 1.5 1.5 0 0 2 2 4.5
B A B B 45 45 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 1.0 (25.4) 1.0 (25.4) AP3650 AP3657 1.88 (47.8) 0.44 (11.2) 3.02 (76.7) 0.13 (3.3) 0.4 (10.2) 1.87 (47.5) A B B 0.44 (11.2) 3.6 (91.4) 45 1.0 (25.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) A B B Connections A B inch inch (mm) (mm) FV4 MV4 TW4 FV6 MV6 TW6 FV4 MV4 TW4 FV6 MV6 TW6
POWER indicator: Red is ON FLOW indicator: OFF If the error cannot be reset after the above measures are taken, then please contact SMC -40No.PF-OMW0004-B Specifications Manifold common specifications Model PF3WB PF3WC PF3WS PF3WR Manifold specifications Integrated type Remote type Arrangement 1 to 10 station 1 Supply: 1 to 5 station Return: 1 to 5 station 1 to 10 station 1 1 to 10 station
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 9 Filter Rc3/8 20m FQ1011N-10-T020-B-X61 Note Note) The filter shown above cannot be directly connected to the thermo-chiller.
C L A B C Lead 20 10 5 2.86 20 10 5 Parameter *1,*2 Para.
0 PB0.02 GA GB VF LA0.1 VA0.02 C VE L 2 x 2 x P H7 depth D 2 x V H7 depth I 4 x NN depth S N 2 x NPT 1/4 G 2 x 2 x MM depth J Hexagon socket head plug 2 x NPT 1/4 G E B RB (mm) Bore size (mm) 50 63 80 C D E GA GB GC I J K L LA LB MM N NA NB NC NN P B 95 48 12 13.7 134.3 138.5 93 10 12 55 376.4 149.5 78.4 M10 x 1.5 19 13 36.5 10.3 M8 x 1.25 10 112 54 12 16.6 141.2 147.5 90.5 10 12 55 395.6
calculation m2 = d x e x f x Relative density m2 = 4 x 5 + 6 x 2.7 x 10-6 = 3.24 x 10-4 (kg) Inertial moment around Z2 axis Z2 = {m2 (d2 x e2) / 12} x 10-6 Z2 = {3.24 x 10-4 x (42 + 52) / 12} x 10-6 = 1.11 x 10-9 (kg.m2) = 1.11 x 10-9 + 3.24 x 10-4 x 23.52 x 10-6 = 0.18 x 10-6 (kg.m2) Inertial moment around Z axis B = Z2 x m2r22 x 10-6 B Thus, the total inertial moment is = A + B = 0.20
Allowable Kinetic Energy Extension locking direction Retraction locking direction 100 100 50 50 Load weight kg Load weight kg 10 10 50 W 50 5 5 40 40 B 32 32 0.5MPa 0.4MPa 0.5MPa 0.4MPa A A 25 25 1 1 100 500 100 500 B W Maximum speed mm/s Maximum speed mm/s B: Retraction locking direction F: Extension locking direction 9-13-4 4 Series MLU Specific Product Precautions 2 Be sure to read before
Supply port 2-M5 x 0.8 FC FA FE FH GD GC GB FG FF EB EA D FB B MIS12-10 A C FD GA Model 72 92 112 86.5 106.5 126.5 33 43 53 38.5 48.5 58.5 48 38 28 165 135 105 185 155 125 MIS12-30 MIS12-20 18 19 9.5 6 (Effective depth 3) 4.5 8 -0.1 0 8 -0.1 0 10 M3 x 0.5 5 3.3 23 26 21 MIS20-30 MIS20-20 MIS20-10 52 42 32 11-0.1 0 11-0.1 0 29.5 35 25.5 13 12.5 10 (Effective depth 4) M5 x 0.8 6.5 28.5 7 5.1
Description Type Model ALB900-10 ALB900-20 ALB900-30 Bypass lubrication adapter AWD ALBA90-10 ALBA90-20 ALBA90-30 Standard attachment Ball valve B B IS440-1 to 2 1 4 ITV Ball valve 1 2 Oil can be replenished by merely opening and closing the oil filler plug without stopping the air line.
Model Option AR20(K)-B AR25(K)-B AR30(K)-B AR40(K)-B AR40(K)-06-B AR50(K)-B AR60(K)-B Bracket assembly Note 1) AR23P-270AS AR28P-270AS AR33P-270AS AR43P-270AS AR52P-270AS Set nut AR23P-260S AR28P-260S AR33P-260S AR43P-260S Note 2) Round type Note 3) Standard G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G36-4-01 G46-4-01 (with color zone) Standard G36-10-01-L G46-10-01-L Pressure Round type