capacity W 1000 Ambient 15C 300 Ambient 35C 800 Ambient 20C Ambient 25C 600 200 400 Ambient 30C 100 200 0 0 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Fluid temperature degC Circulating fluid temperature degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700
LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800
characteristics 5%F.S. max. (0 to 90 C, 25 C reference) Withstand voltage 1000 VAC, for 1 minute between the external terminals and case Insulation resistance 50 M or more (at 500 VDC) between external terminals and case Standards and regulations CE, RoHS Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Materials of parts in contact with fluid SUS, NBR 4, PPS Product 460 g 5 520 g 5 700
The SYJ3000/5000/7000 series and the SYJ300/500/700 series can be mounted on the same manifold. How to mount on the same manifold is shown on the following pages. SYJ300P.17 SYJ500P.19 SYJ700P.21 Locked position When locking the manual override on the push-turn locking types (D, E), be sure to push it down before turning.
LAT3LAT3MLAT3F600 350 700 Load weight1000g Load weight1000g Load weight1000g 300 600 Positioning time [ms] Positioning time [ms] Positioning time [ms] [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
End-lock type (Cylinder with end lock) 16 20 25 32 40 Lock position Single side (selectable), both sides Holding force (max.)N 110 170 270 450 700 Stroke fine adjustment range (mm) 0 to -5.6 0 to -6 0 to -11.5 0 to -12 0 to -16 Backlash 1mm or less Manual release Possible (Non-locking type) Warning 1.
Series SYJ3000/5000/7000 and Series SYJ300/500/700 can be mounted on the same manifold. How to mount on the same manifold is shown on the following pages. If 4 or 5 port valve is used as a 3 port valve Series SYJ3000,5000,7000 may be used as a N.C. or N.O. 3 port valve by plugging one of the A,B ports. Be sure not to plug the exhaust ports (R).
HRW008-H HRW015-H HRW030-H HRW002-H1 HRW008-H1 HRW015-H1 HRW030-H1 HRW002-H2 HRW008-H2 HRW015-H2 HRW030-H2 HRW002-HS HRW008-HS HRW015-HS HRW030-HS HRW002-H1S HRW008-H1S HRW015-H1S HRW030-H1S HRW002-H2S HRW008-H2S HRW015-H2S HRW030-H2S 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min MAX 30s 20s Operating Time 10s 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700
Long stroke (mm) Bore size (mm) Model Data Slide bearing 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Auto Switch Mounting Bracket Part No. 25 350, 400, 450, 500 75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700
Weight Unit: g 10 20 30 50 Size Basic type 700 1300 1670 2570 High precision type 730 1400 1790 2730 Note) Excluding the weight of auto switches. Piping and Speed Conrol 1) A single 3-position pressure center solenoid valve or two 3-port solenoid valves are used.
(Initial conditions) 200 0.05 32 SFE1 SFE3 Inlet pressure/Back pressure [MPa] 150 SFE5 0.04 25 100 SFE4 SFE7 95 20 0.03 50 10 0 0.02 0 100 200 300 400 500 600 700 800 Cylinder driving speed [mm/s] AN 0.01 AMC Example) Bore size: 32, Driving speed: 400 mm/s, Supply pressure: 0.5 MPaG 1. From the graph, exhaust flow rate is found to be 95 L/min (ANR). 2.
UNF depth 0.25 (6.3) (Mounting hole) 0.28 40 0.24 35 4 Delivery pressure (MPa) Delivery pressure (psig) 1.0 (25.4) 0.21 30 5 0.17 25 0.14 20 A Connections (mm) inch FV4 MV4 TW4 FV6 MV6 TW6 0.10 15 (70.6) 2.78 0.07 10 2.12 (53.8) 0.03 5 3.86 (98.0) 0.00 0 0 5 10 15 20 25 30 35 40 45 50 Flow rate (slpm, N2) 2.65 (67.3) SL5201A High flow option Inlet pressure: 2 psig (14 kPa) Standard 760 0 700
Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of
Flow Direction Symbols on Body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS Symbol ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 Metric size 4, 6 8, 10 1/8" 5/32" 3/16" 1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min}
Flow Direction Symbols on Body Meter-out type Meter-in type Flow Rate and Effective Area ASD230F ASD330F ASD430F ASD530F ASD630F Model 8, 10 10, 12 10 12 Metric size 4, 6 6 8 6, 8 6 Symbol JIS Symbol 1/8" 5/32" 3/16" 1/4" 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate (l/min (ANR)) 350 5.3 1200 18.3 500 7.6 700 1300 19.8 75 1.1 175 2.7 600 9.1 10.7 295 4.5
Flow Direction Symbols on Body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS Symbol ASD230FG ASD330FG ASD430FG ASD530FG ASD630FG Model 8, 10 3/16" 1/4" 1/8" 5/32" 6 8 10, 12 10 12 Metric size 4, 6 6, 8 6 1/4" 5/16" 3/8" 3/16" 1/4" Tubing O.D. 1/4" 5/16" 3/8" 3/8" Inch size Flow rate (l/min (ANR)) Controlled flow (Free flow) 350 295 75 175 500 600 700 1200 1300 5.3
Flow Rate and Effective Area Flow Direction Symbols on Body ASD230F ASD330F ASD430F ASD530F ASD630F Model Meter-out type Meter-in type 8, 10 6 8 10, 12 10 12 Metric size 4, 6 6, 8 6 1/8" 5/32" 3/16" 1/4" 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Symbol JIS Symbol Flow rate (l/min (ANR)) Controlled flow (Free flow) 295 4.5 75 1.1 175 2.7 350 5.3 500 7.6 600 9.1 700
Lube Unit ALDU600-l06 to 10, ALDU900-l12 to 20 A B C D E F G H J K L M N P Q R S Model Port size 3/4 283 296 424 424 476 67 77 85 90 100 43 10 57 51 16 ALDU600-l06 ALDU600-l10 ALDU900-l12 ALDU900-l14 ALDU900-l20 135 345 460 145 90 150 480 20 430 470 175 87.5 30 62.5 1 1/4 1/2 615 615 682 419.2 209 1 1 1 250 125 33.2 33.2 710 670 20 700 230 120 222 1.17-19 Booster Lube Series ALB900 Standard
Symbol indication of flow direction on the body Meter-out Meter-in Air Flow/Effective Area Symbol JIS Symbol ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 Metric 4, 6 6 8, 10 6, 8 1/4" 5/16" 3/8" 1/8" 5/32" 3/16" 1/4" Tube O.D. 1/4" 5/16" 3/8" 3/8" Inch 500 600 700 1200 1300 175 295 350 75 Air flow (l/min(ANR)) Controlled (free)/Flow 7.6 9.1 10.7 18.3 19.8 1.1 2.7 4.5 Eff
HAl Accessories (Options) HAA7 AT Auto drain Applicable Model HAA7 HAA15 HAA22 HAA37 HAA7-F AD402-03 HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F AD402-03 HAA22-S HAA37-F AD402-04 IDl Dust protecting filter Mounting bench HAA37-S AMG How to Select (Flow Capacity l/min (ANR)) Operation Principle AFF Model HAA7 HAA15 HAA22 HAA37 AMl 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000