Search Results "ZSE20B-L-01-W"

block gauge pressure supply block L side L side switch block Nil A B C D E F G H J K L M N O P Q R F.R.L.

block gauge pressure supply block L side L side switch block Nil A B C D E F G H J K L M N O P Q R F.R.L.

plug connector with cover (LL) 52-SY5120-LL-01 (-F2) Insulation: Red (+) Insulation: Black () 4.1 0.3 mm2 12 14.7 L 104 (Lead wire length) Cable type (TT) 52-SY5120-TT-01 (-F2) Lead wire marking No.1 (+), No.2 () 5.9 0.75 mm2 L 120.8 (Lead wire length) Max.10 5 ATEX Compliant Body Ported Type Series 52-SY5000 Dimensions 2-position double L plug connector (L) 52-SY5220-L-01 (-F2) 22.6 16.7

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

HRX-OM-Q026-V Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH Series HRSH100-A-20HRSH100-A-40HRSH100-A-20-S HRSH150-A-20HRSH150-A-40HRSH150-A-20-S HRSH200-A-20HRSH200-A-40HRSH200-A-20-S HRSH250-A-20HRSH250-A-40HRSH250-A-20-S HRSH300-A-20HRSH300-A-40HRSH100-W-20HRSH100-W-40HRSH100-W-20-S HRSH150-W-20HRSH150-W-40HRSH150-W-20-S HRSH200-W-20HRSH200-W-40HRSH200

(Size: 01) EVS1-02 (Size: 02) 100 80 1000 l/min (ANR) 400 l/min (ANR) Accommodates enclosure IP65 Dust/Splashproof type Lightweight Size 01 (3 position): 0.26 kg Size 02 (3 position): 0.18 kg 3-11-11 12 ISO Standard Solenoid Valve Size 1,2/Single Unit Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 Courtesy of Steven Engineering

2 i r i t y w w e !0 !0 !2 !5 o !0 !4 q q y u !1 !3 r t !1 M5 type U10/32 type M5 type U10/32 type !1 y !2 u !4 !3 i !5 u e r r t w e o !0 i o q q t y !0 !2 w !

[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less

010 050 1000 mm 5000 mm l Terminal no.

The basic parameter is not correct for the following condition: (Assignable value range) (1) Stroke (-) < Stroke (+) (2) W-Area 1 < W-Area2 (If both W-Area1 and W-Area2 is 0, the alarm will not be activated.) (3) Maximum pushing force < Maximum pushing force of The Parameter value is incorrect (01-049) System B RESET the electric actuator parameter input error

: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 01, 23, 03, 04, 06, 07 500 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification

(Except L kit) F, P and S kits are provided with an exhaust on one side, while L kits are with an exhaust on both sides. Note 1) 01 1 station Note 2) The number of max. stations differs from kit to kit. (Refer to the table below.)

..3/8 U04 ..1/2 U32 ..10-32UNF 01 ... 1/8 02 ... 1/4 03 ... 3/8 04 ... 1/2 W I T H O N E-T O U C H F I T T I N G S T Y P E 2 Elbow 3 Universal C O N T R O L M E T H O D 0 Meter Out 1 Meter In Courtesy of Steven Engineering, Inc. !

Stroke Against Lateral Load D 17 24 27 29 0.7 W W W 500 82 103 116 127 0.3 Bushing (Bearing) fR U 62 79 89 97 0.5 Lateral load applied to rod end (fR) N 100 52 66 75 81 0.7 50 33 43 49 53 0.3 10 23 31 36 39 T 0.5 REC40 REC32 REC25 REC20 5 18 25 29 31 0.7 2 Rod side flange style: F Head side flange style: G 182 167 148 118 Foot style: L 0.3 1 L 140 128 114 90 0.5 0.5 W W W F REA 117 108 95