SMC Corporation of America
Elite Part Number Search
Search Results "ZSE10F-M5-E"

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, 0.18004 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, .17085 lb, ModelRated pressure rangeSet pressure range/Pressure display rangeWithstand pressureMinimum unit settingFluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputDisplayDisplay

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function. Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., VACUUM SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JC, ZSE30 1/

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certification

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certification: K (w/Certificate

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certification: K (w/Certificate)