SMC Corporation of America
Elite Part Number Search
Search Results "XLG-25L-2M9BA"

Flange Size: -, Flange Type: -, Port Direction: -, Temperature: -, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 16, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: M (M Type Plug Connector), Surge Suppressor

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: M (M Type Plug Connector), Surge Suppressor

Valve Type: Normally Closed, Bellows Seal, Flange Size: 16, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: M Type Plug Connector, Surge Suppressor: w/Surge Voltage

Valve Type: Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/Indicator, Rear Flange Surface, Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: M Type Plug Connector, Surge Suppressor: w/Surge Voltage

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: G [Grommet (Lead Wire Length 300mm)],

Flange Size: 40, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Flange Size: 50, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 16, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: No auto-switch (no magnet), Number Of Switches:

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: No auto-switch (no magnet), Number Of Switches:

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: No auto-switch (with magnet), Number Of Switches

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9B solid-state auto switch, Number Of Switches

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 25, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: D-M9B solid-state auto switch, Number Of Switches

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 40, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: No auto-switch (no magnet), Number Of Switches:

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 40, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: No auto-switch (with magnet), Number Of Switches

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 40, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 150, Switch Part Number: No auto-switch (no magnet), Number Of Switches

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 50, Seal Type: Elastic Seal, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 60, Switch Part Number: No auto-switch (no magnet), Number Of Switches: