SY3000-54-3C(-Q) SY5000-54-2C(-Q) SY7000-54-3C(-Q) Port size One-touch fitting for 5/16" One-touch fitting for 3/8" One-touch fitting for 3/8" Applicable series SY3000 SY5000 SY7000 SZ VP4 S0700 [When 2 different EXH passages are required.] [When supplying the manifold with 2 different supply pressures.]
(Ambient temperature of 25 3C) Analog output linearity 1% F .S.
Response time (With anti-chattering function) Output short circuit protection Display 2% F .S. 1 digit or less (at ambient temperature of 25 3C) Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON) Output voltage: 1 to 5 V 5% F.S. or less (in rated pressure range) Linearity: 1% F .S. or less Output impedance: Approx. 1 k No-voltage input (Reed or solid state), input 5 ms or more
(Ambient temperature of 25 3C) Analog output linearity 1% F .S.
0D Answer 25.0 deg.C Temperature setting (without writing EEPROM) 2 01 32 02 31 32 35 30 30 03 32 3C 0D 06 32 OD Set at 25.0 deg.C 31 32 Reading internal sensor 2 01 32 05 32 36 39 0D 01 32 02 32 32 35 30 32 03 32 3F 0D Answer 25.02 deg.C 33 Reading external sensor 2 01 32 05 33 36 3A 0D 01 32 02 33 33 30 30 32 03 32 3C 0D Answer 30.02 deg.C 34 Reading alarm status 2 01 32 05 34 36 3B 0D
Examples of commands and answers from the thermo-con (unit specified) Command Command Unit Host requirement Answer from thermo-con code (ASCII code) Content specified (ASCII code) ASCII 31 Reading setting temperature 2 01 32 05 31 36 38 0D 01 32 02 31 32 35 30 30 03 32 3C 0D Answer 25.0 deg.C 31 Temperature setting (without writing FRAM) 2 01 32 02 31 32 35 30 30 03 32 3C 0D 06 32 OD Set
Data Maximum Settable Temperature Graph 1: IDH4 Graph 2: IDH6 F 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) Air flow capacity scfm (L/min [ANR]) 17.6 (500) 28.3 (800) Air flow capacity scfm (L/min [ANR]) 15.9 (450) Selection example 24.7 (700) 14.1 (400) 21.2 (600) 12.4 (350) Selection example Selection example 10.6
Piping port thread ty pe Rc Rc C2SL-6-A C2SL-6C-A G G NPT C2SL-6(Z)-A NPT C2SL-6C(Z)-A Semi-standard symbol 3 36 3C 36C Semi-standard: 3 Semi-standard: 3C (7) Part No. Piping port thread ty pe Piping port thread ty pe (7) Part No. Rc Rc C2SL-3-D C2SL-3C-D G G NPT C2SL-3(Z)-D NPT C2SL-3C(Z)-D Appearance and part No.
assembly 1 2 position single 2 2 position double SY9000-37-4B 3 3 position closed center For 110VAC (115VAC) 4 3 position exhaust center Specification Single solenoid Double solenoid/ 3 position SY9000 SY9000-37-1C 5 3 position pressure center Pilot specification SY9000-37-2C A, B port size Nil Internal pilot External pilot R Single solenoid with spacer assembly Symbol Port size C8 SY9000-37-3C
If the circulating fluid temperature falls below 3C, the pump will start operating automatically. The heat generated by the pump operation will warm up the circulating fluid. When the temperature rises above 5C, the pump will stop automatically. As a result, the circulating fluid maintains a temperature of between 3C and 5C, preventing freezing. 2.
P407090-1 P406090-3D MRHQ10D Switch holder B P406090-3S MRHQ10S P407060-1 P406090-3C MRHQ10C Switch case P406060-3D MRHQ16D P406060-3S MRHQ16S P406060-3C MRHQ16C P407080-3D MRHQ20D P407080-3S MRHQ20S Switch holder A P407080-3C MRHQ20C P408080-3D MRHQ25D Two of each part indicated at the left are included in a unit. Switches are not included with a unit.
SY3000-54-3C(-Q) SY5000-54-2C(-Q) SY7000-54-3C(-Q) Applicable series 10-SY5000 10-SY3000 10-SY7000 10-SY5000 10-SY7000 [When supplying the manifold with 2 different supply pressures.] [When 2 different EXH passages are required.]
Power valve series VEX includes a regulator valve (VEX1*0), precision regulator (VEX1*3), 3 position valve (VEX3) and a economy valve (VEX5). The 3 port large capacity poppet exhausting regulator is equipped with a relief port the same size as the connection port. The 3-port, 3-position double solenoid that permits vacuum suction, vacuum destruction, & suspension (closed) is ideal for a
Solenoid: No.2 Solenoid, Body Option: 7 (32A), Style: 2 (Energized Closed/N.O.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (35A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com