How to Order Valves 5 L N SX 5 1 20 01 Thread type Series A, B port size Nil Applicable series Rc Symbol Port size M5 x 0.8 3 SX3000 5 SX5000 G F M5 One-touch fitting for 4 C4 N 7 SX7000 NPT SX3000 One-touch fitting for 6 C6 NPTF T Type of actuation 1 8 01 1 2 position single One-touch fitting for 4 C4 Rated voltage SX5000 2 2 position double One-touch fitting for 6 C6 5 24 VDC 6 12 VDC 3
D ENSIONS A B c D E F 2.66 (67.5) 2.42 (61.5) (14) 0.28 17', 0.16 (4) 1.42 (36) ,ltrF-l rD C Solsnoid DIN "Electricrl Connector" 'AC" Vottage only ml--l l "*---l-l I .f;T.
Flow Direction Symbols on Body Meter-out type Meter-in type Symbol JIS Symbol 15-9-67 Series ASD-FM How to Order ASD 3 3 0 F M 01 06 S With seal M5 and U10/32 types, as they are not available with seal. Body size 2 3 4 M5 standard 1/8 standard 1/4 standard Type Applicable tubing O.D.
Alarm code Alarm message Operation status Main reason 01 Liquid deposits in the base of this unit.
[F 3] Digital filter setting completed -44No.PF-OMW0007-E
[F 4] Auto-preset function setting This function will automatically calculate and set the optimum pressure based on the actual operating condition, when hysteresis mode has been selected.
RE A B Model Recommended Speed Controller REC Model Elbow type Straight type In-line type CX REC20 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REC25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 CY REC32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS3001F-08-X214 REC40 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way
lOre mentioned above 8'8 1 00 same as standard port locatIon C95 Standard part number l-xC3 j B f@] Location 01 pons and cushion val\les On rod cover and head CO\lfH.
KPGH04-02 KPGH06-M5 KPGH06-01 KPGH06-02 KPGH08-01 KPGH08-02 KPGH10-02 KPGH10-03 KPGH12-03 KPGH12-04 KPQH04-M5 KPQH04-01 KPQH04-02 KPQH06-M5 KPQH06-01 KPQH06-02 KPQH08-01 KPQH08-02 KPQH10-02 KPQH10-03 KPQH12-03 KPQH12-04 25.4 25.9 25.4 22.9 26.3 26.8 25.6 26.1 32.6 30.6 37.6 33 34.1 34.1 8 M5 22.5 10 4 4 4 18 4 10 14 1/8 1/4 19.5 17 7 12 M A L H Connection threads 8 M5 23 12 5 6 10 10
KPGH04-02 KPGH06-M5 KPGH06-01 KPGH06-02 KPGH08-01 KPGH08-02 KPGH10-02 KPGH10-03 KPGH12-03 KPGH12-04 KPQH04-M5 KPQH04-01 KPQH04-02 KPQH06-M5 KPQH06-01 KPQH06-02 KPQH08-01 KPQH08-02 KPQH10-02 KPQH10-03 KPQH12-03 KPQH12-04 25.4 25.9 25.4 22.9 26.3 26.8 25.6 26.1 32.6 30.6 37.6 33 34.1 34.1 8 M5 22.5 10 4 4 4 18 4 10 14 1/8 1/4 19.5 17 7 12 M A L H Connection threads 8 M5 23 12 5 6 10 10
. / . 100 16.2 . 101 16.3 . 102 16.4 . 102 16.5 . 103 16.6 . 103 16.7. . 103 17. . 104 17.1 . 104 17.2 . 107 1. . 108 1.1 LEY/LEYG . 108 1.2 LEFS . 108 1.3 LES(H) . 109 1.4 LEP . 109 1.5 LEFB . 110 1.6 LER . 110 1.7 LEH . 110 -4No.JXC-OMT0001CN-C JXC93 Series 1. 1) (ISO/IEC)(JIS) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic
A C A d A E A F A H A A (1) b # # Ready-off Ready-off (1) d # # ON ON (1) C # # OFF OFF (2) * * No.No.81 8 8 8 CPU CPU (3) 0 0. b JOGDO (1) # #. b (3) # #. d # #. C 1. ##0016 ## 00 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 2. **No. 3.
65 41 A 97 61 a 2 2 STX 34 22 " 66 42 B 98 62 b 3 3 ETX 35 23 # 67 43 C 99 63 c 4 4 EOT 36 24 $ 68 44 D 100 64 d 5 5 ENQ 37 25 % 69 45 E 101 65 e 6 6 ACK 38 26 & 70 46 F 102 66 f 7 7 BEL 39 27 ' 71 47 G 103 67 g 8 8 BS 40 28 ( 72 48 H 104 68 h 9 9 HT 41 29 ) 73 49 I 105 69 i 10 0A LF 42 2A * 74 4A J 106 6A j 11 0B VT 43 2B + 75 4B K 107 6B k 12 0C FF 44 2C , 76 4C L 108 6C l 13 0D CR 45 2D
ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).
ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).
LVQ 1 (1.5 mm) 2 (2.2 mm) 3 (3 mm) 4 (4 mm) VXA31 VXA32 LQ 01 ( ) 1 8 02 ( ) 1 4 02 ( ) 1 4 03 ( ) 3 8 LVN TI/ TIL Ordering example (Example) Series VXA31, Orifice size 1.5 mm, Rc 1/8 (Part no.) VXA3114-01 PA PAX PB 17-3-103 The VX series will be revised shortly.
) 44.5 93 (103) 28 101 (111) 93 (103) 60 25.5 40 132 142 (157) 54.5 60 72 VXR2380-14 1 VXR2382-14 30 62 97 64 50 98 (108) 44.5 98 (108) 28 106 (116) 98 (108) 69 25.5 40 150 153 (168) 59 35.5 70 81 VXR2390-20 2 VXR2392-20 ( ): N.O. 17-3-60
Non plug-in type N T F Symbol 24 24 stations NPTF G Option VV5ZS3-51FD-091-01-MP5 VZS3150-5FZ VZS3250-5FZ 1 5 2 Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Note) Maximum stations 51F 16 stations 51G 15 stations 51 24 stations Symbol Port size 1 1 8 02 Rc 1 4 01 Rc (Manifold base) (2 position single) VV5ZS3-50-071-01-M5 VZS3150-5G 1 5 Embedded type One-touch
Nil V Standard For vacuum X505 VPA500 series Port size Symbol Port size VPA300 1/8 1/4 3/8 1/2 VPA500 VPA700 01 02 03 04 Bracket Nil F Without bracket With bracket Thread type Type of actuation A B N.C. (Normally closed) N.O. (Normally open) Nil F N T Rc G NPT NPTF VPA700 series Specifications Fluid Air Type of actuation N.C. or N.O.
8 for details. 711 AS-FPQ/FPG Series How to Order AS 2 1 1 2 F P Q 01 06 Lock nut option Nil J Body size Hexagon lock nut Round lock nut 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.