S Short circuit detection Diagnostic function which detects generation of over current due to a short circuit between the output and the positive power supply line or the ground line. Short circuit protection Function which avoids damage to the internal circuit when over current is generated due to short circuit between the output and the positive power supply line or the ground line.
T kit (Terminal block) P kit (Flat ribbon cable connector) S kit (Serial transmission) Kit F kit (D-sub connector) F 25P U S P 26P U S F A 15P U S P C 20P U S P 16P U S B P A 10P U S S Type T1 T2 Max. points Note) 16 Note) 16 16 16 Note) 16 14 14 8 8 Note) Due to the limitation of internal wiring.
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit (Circular connector) T kit (Terminal block box) S kit (
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Components Solenoid valve System Silencer Speed controller SPG (Steel pipe) dia. x Length 10A x 1 m Series VFR4000 Rc Series VFR4000 Rc AS4000-03 (S = 21mm2) AS420-03 (S = 73mm2) AN300-03 (S = 60mm2) AN300-03 (S = 60mm2) A 3 8 B 10A x 1 m 3 8 Series VFR4000 Rc AN400-04 (S = 90mm2) AS420-04 (S = 97mm2) 1 2 C 15A x 1 m How to
VNA1A -6A, 8A, 10A VNA2 -10A, 15A No.
D0 D1 D2 U0 U1 U2 1 to 16 stations Kit L Kit L SD S Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 output points) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 output points) DeviceNet OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) CC-Link Note 1) For the T kit and S kit, 2 stations are required to mount the terminal block
50A 10A to 50A 10A to 25A 32A to 50A 10A 15A to 50A 10A to 50A 10A to 50A 10A to 50A 10A to 50A 1 1 Body Body CAC407 CAC407 Stainless steel Stainless steel Brass (C37) Brass (C37) 2 2 Bonnet Bonnet CAC407 CAC407 Nut O-ring O-ring Nut O-ring O-ring 3 4 5 3 4 5 Brass (C37) NBR NBR Stainless steel, NBR Stainless steel, NBR Brass (C37), Ni plated FKM, EPDM FKM, EPDM Brass (C37), Ni plated FKM
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Components VQ7 Solenoid valve System Silencer Speed controller SGP (Steel pipe) Port size x Length EVS AS420-03 (S = 73 mm2) AN300-03 (S = 60 mm2) 10A x 1 Series VFS4000 Rc A 3 8 VFN AS420-04 (S = 97 mm2) 15A x 1 AN400-04 (S = 90 mm2) Series VFS4000 Rc B 1 2 Double Check Spacer/Specifications Can hold an intermediate cylinder
Linearity (77F) 0.15% F .S. Repeatability (77F) 0.6% F .S. 0.5% F .S.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Components Solenoid valve System Silencer Speed controller SPG (Steel pipe) dia. x Length 10A x 1 m Series VFR4000 Rc 3/8 Series VFR4000 Rc 3/8 AS4000-03 (S = 21 mm2) AN300-03 (S = 60 mm2) A AS420-03 (S = 73 mm2) 10A x 1 m AN300-03 (S = 60 mm2) B 15A x 1 m Series VFR4000 Rc 1/2 AN400-04 (S = 90 mm2) AS420-04 (S = 97 mm2) C
1) _ S L, Z _ S L, Z T Manifold base Mark Applicable valve VX21l1-00 VVX21 VVX22 VVX23 Port size VX22l1-00 VX23l1-00 1 2 Rc(PT) Rc(PT) 1 8 1 4 AC All common ports are 3/8.
[mm] Model D1 D2 L Weight [g] 8 KQ2C-08A 12.8 9.2 2.6 0.1 10 KQ2C-10A 15.2 11.2 2.7 0.1 12 KQ2C-12A 17.6 13.2 2.7 0.1 16 KQ2C-16A 22.4 17.2 3.2 0.2 Applicable tubing O.D.
C M S C C S M C S M NI NI IN IN OUT OUT B B 2 To CYL port To CYL port 4 P.960 P.961 P.962 P.974 Connector assembly SY3000-37-80AHousing (1 set: 8 pcs.)
S kit (Serial transmission) Kit F kit (D-sub connector) T kit (Terminal block) P kit (Flat cable connector) F 25P U S P 26P U S F 15P U S A S U S P 16P U S B P 20P U S C P A 10P Model T1 T2 (1) (1) (1) Max. number 16 14 16 16 14 8 8 16 16 Note 1) Due to the limitation of internal wiring.
The S kit is compatible with a combined I/O Unit.
www.stevenengineering.com I 2.89 SOLENOID VALVES SERIES VQZ BODY PORTED TYPE M A N I F O L D O P T I O N S E R I E S V Q Z 1 0 0 0 / 2 0 0 0 / 3 0 0 0 B L A N K P L A T E A S S E M B L Y BLANK PLATE ASSEMBLY VVQZ1000-10A-2 VVQZ2000-10A-2 VVQZ3000-10A-2 USED TO RESERVE A VALVE MOUNTING SPACE ON THE MANIFOLD FOR FUTURE USE M A N I F O L D O P T I O N S E R I E S V Q Z 1 0 0 0 / 2 0 0 0 / 3
Enter EX250-compliant S kit only. Valve stations Input block specification (Enter EX250-compliant S kit only.)
SOL.A 8A () (+) SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 8B () (+) 8 stations SOL.B 8B SOL.A 9A () (+) SOL.A 9A SOL.B 9B () (+) 9 stations SOL.B 9B SOL.A 10A () (+) SOL.A 10A SOL.B 10B () (+) 10 stations SOL.B 10B (+) () COM COM Note) There is no polarity.
D DIN terminal DL DIN terminal with light DO DIN terminal (without connector, with gasket) Orifice diameter and Port Size Combinations T Conduit terminal Class Orifice diameter (mm) Port size 2 4 3 7 5 10 1/8 ( 6A) V V V V 2 1/4 ( 8A) V V V V 1/4 ( 8A) V V V V 3 3/8 (10A) V V V V V 1/2 (15A) V Connector 1/4 ( 8A) V V V V 3/8 (10A) V V V V V All class B coils come with surge
Conduit: C DIN terminal: D E U V U Approx. 280 E 31.5 (44) G1/2 T T G1/2 R R Cable 6 to 12 Applications B B 8 x 18 8 x 18 F F S S Conduit terminal: T (V) (U) E 25 32 G1/2 R T B 8 x 18 F S (mm) Electrical entry Grommet Model Applicable flange Conduit DIN terminal Conduit terminal U 103.5 106 106 B C D A E F H N Q R S N.C.