g 1,100 g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W2/3.
F G J V , w K I KA l w LH LS 43 15 M14 x 1.5 15 17 15 27 I 19 85 188 15 I' 27 I Hi 100 188 17 I 34 I 19 106 206 43 15 M14 x 1.S ., 15' 1?
Q 26 R 4.5 S 1.6 AMG150C AMG250C AMG350C AMG450C AMG550C 10 99 63 20 63 10 1/8, 1/4 158 14 113 76 20 76 10 190 66 24 8 6 6 12 6 10 40 66 80 28 5 2 1/4, 3/8 172 18 145 90 20 90 10 222 80 28 8 7 7 14 7 12 50 80 95 34 5 2.3 3/8, 1/2 204 20 166 106 20 106 10 246 90 31 10 9 9 18 9 15 55 88 111 50 9 3.2 1/2, 3/4 225 24 200 122 20 122 15 278 100 33 10 9 9 18 9 15 65 102 126 60 10 3.2 3/4, 1 259
setting in auto tuning mode 1 . 14 6.4 2-gain adjustment mode . 15 6.5 Manual mode . 16 6 1 6.
E AKM3000-A 1/8, 1/4 53 34 14 48 13 AC25-B AC30-B, AC30A-B AKM4000-A 1/4, 3/8 70 42 18 54 15 AC40-B, AC40A-B1 IN OUT B 1 Cannot be mounted on the AC40l-06-B.
A 1-B 1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 1/8, 1/4 500 1.5 0 1,000 2,000
2 1/2 205 202 11 90 262 20 146 9 18 108 55 31 9 15 276 262 26 Series IDG1 I N SMC SMC SMC 2 SMC 202 60 Port size 1/8, 1/4 119 41.5 30 Dew point indicator (Option: S) 5.5 29 24 24 67 OUT IN 10 116 Drain Discharge 9 133.5 140 136 97 With float type auto-drain (N.C.) 3.2 5.5 Purge air for dehumidification 12
Scale: 30% 72.4 92.5 (5.5) (13.8) 60.9 (5.5) 20 81 (5.5) n 1 2 Stations (Indicator light/Surge voltage suppressor) + + + + + + SUP port Rc 1/4 EXH port Rc 1/4 (both sides) 81 + 60 5 E 1 P 10 20 10 1 1 Height when using DIN rail L1 (5) L2 (Rail mounting hole pitch: 12.5) 13.5 13.5 (L4) L3 L5 15 2-M5 (external pilot port)
Different surfaces Different surfaces Same surface Same surface (n 2) 2 55 + 35 (n 2) 20 + 35 D-M9 5 15 Note 1) 40 Note 1) (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 55 + 35 (n 2) 20 + 35 D-M9W 15 Note 1) 40 Note 1) 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 60 + 35 (n 2) 25 + 35 D-M9A 25 40 Note 1) 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 50 + 35 (n 2) 15 + 35
Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable
Hirose Electric Co., Ltd. 55 2 x M2.6 x 0.45 Socket side 14 25 1 13 47.04 Terminal no. Note 1) Types with 15 pins are also available. Refer to page 55 for details. Note 2) Lengths other than the above are also available. Please contact SMC for details.
x 1.5 to 1200 (mm) Bore size (mm) Stroke range (mm) 125 140 160 K KA M MM N P S W H ZZ 15 31 19 M30 x 1.5 35 1/2 98 110 332 to 1000 8 15 31 19 M30 x 1.5 35 1/2 98 110 338 to 1000 9 17 36 22 M36 x 1.5 39 3/4 106 120 378 to 1200 With rod boot (mm) Bore size (mm) 125 140 160 Stroke range (mm) l ZZ1 h 1/5 stroke 30 to 1000 133 355 1/5 stroke 30 to 1000 133 361 1/5 stroke 30 to 1200 141 399
Same surface 35 100 110 2 D-A3 D-G39 D-K39 110 + 30 (n 2) (n = 2, 4, 6, 8 ) 35 + 30 (n 2) Different surfaces n 110 + 100 (n 2) (n = 2, 4, 6, 8 ) Same surface 100 + 100 (n 2) 1 110 15 Different surfaces Same surface 35 55 2 110 110 + 30 (n 2) (n = 2, 4, 6, 8 ) 35 + 30 (n 2) Different surfaces D-A44 n 110 + 50 (n 2) (n = 2, 4, 6, 8 ) 55 + 55 (n 2) Same surface 15 110 1 D-Z7 D-Z80 D-Y59
88 12 14 26 12 M6 x 1 depth 9 21 100 st or more 25 25 25 350 to 500 175 80 37 46 57 100 88 13 14 31 12 M6 x 1 depth 13 21 125 st or more 32 32 32 350 to 600 201 82 37 52 65 114 90 16 14 38 12 M6 x 1 depth 13 21 150 st or more 40 40 40 350 to 800 238 92 44 62 84 138 101 20 15 47 12 M8 x 1.25 depth 16 25 200 st or more 50 50 50 350 to 1000 285 104 55 75 94 164 116 25 16 58 14 M10 x 1.5 depth
110 + 50 (n 2) n = 2, 4, 6, 8 55 + 55 (n 2) 1 110 15 D-Z7/Z80 D-Y59/Y7P D-Y7W 115 110 105 15 1, 2 125 to 160 D-Y69/Y7PV D-Y7WV 95 90 10 100 D-Y7BAL 125 120 115 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
Different side 110 35 Same side 110 55 D-A44 Different side 110 + 30 (n 2) n = 2, 4, 6, 8 35 + 30 (n 2) Same side "n" pcs. 110 + 50 (n 2) n = 2, 4, 6, 8 55 + 55 (n 2) 1 pc. 110 15 Cylinder Unit Auto Switches/Proper Mounting Position and Height for Stroke End Detection
10.5 5.5 40 38 12 25 12 16 18 35 5 6.6 55 11 5.5 50 46.5 15 27 16 21 20 40 5 51 9 65 15 6.5 63 56.5 15 32 16 21 23 45 5 9 75 15 6.5 80 72 18 36 20 25 27 45 5 11 95 18 10 100 89 18 41 20 25 30 55 11 115 18 10 5 6-13-11 11 Series CP95 Dimensions: Cylinder Mounting Accessory DS and ES [First angle projection] Mounting style (DS) Bore size (mm) E B1 B2 B3 TG1 T I2 FL d2 d3 CN R H SR (max)
10.5 5.5 40 38 12 25 12 16 18 35 5 6.6 55 11 5.5 50 46.5 15 27 16 21 20 40 5 51 9 65 15 6.5 63 56.5 15 32 16 21 23 45 5 9 75 15 6.5 80 72 18 36 20 25 27 45 5 11 95 18 10 100 89 18 41 20 25 30 55 11 115 18 10 5 6-13-11 11 Series CP95 Dimensions: Cylinder Mounting Accessory DS and ES [First angle projection] Mounting style (DS) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San
(Different surfaces) 15 15 15 1 pc. 15 15 10 2 pcs. (Same surface) 25 25 25 D-A9V 2 pcs. (Different surfaces) 10 10 10 1 pc. 5 5 5 2 pcs. (Same surface) 30 30 30 D-M9V 2 pcs. (Different surfaces) 10 10 10 1 pc. 5 5 5 2 pcs. (Same surface) 55 55 55 D-M9 D-M9W 2 pcs. (Different surfaces) 15 15 15 1 pc. 15 15 10 2 pcs. (Same surface) 30 30 30 D-M9WV 2 pcs.
Symbol 32 40 50 63 1 pc. 2 pcs. "n" pcs. Model A B Same side Different sides 4 6.5 8 8 Different sides Same side D-C7, D-C8 31.5 29.5 31 31 n-2 2 15 + 45 ( ) (n = 2, 4, 6...) Approx. Hs D-C7, D-C8 30.5 35 40.5 40.5 50 + 45 (n-2) 15 50 A B 4 6.5 8 8 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) D-C73C 31.5 29.5 31 31 D-C73C 15 65 65 + 50 (n-2) Approx.