SMC Corporation of America
Elite Part Number Search
Search Results "RLQL32TN-75-BR"

<br>(1) U-shaped slide bending test: more than 10,000,000 cycles (Test conditions: bending radius = cable outer diameter ø5.5 x 6 times, slide distance = 300 mm, approx. 40 times/min)<br>(2) 90-degree bending test: more than 10,000,000 cycles (Test conditions: bending radius = cable outer diameter ø5.5 x 6 times, load 0.9 kg, approx. 30 times/min)<br><br>Note 1) The motor cable of approx.

(e.g., when the leakage rate is 20 L/min (ANR), the vacuum pressure of a ZH10□SA is -20 kPa and the vacuum pressure of a ZH10□LA is about -32 kPa, so the L type has a higher vacuum pressure) <br>The ZH series catalog can be found here.<br><br>

<br>The new ZK2□A series vacuum unit was released in June 2019.<br>The pilot valves for the supply valve and release valve have been changed, but the connector, flow rate characteristics, vacuum performance, and mounting dimensions are the same as those of old ZK2 series vacuum units.<br>Pressure switches and manifold DIN rail mounting brackets can be retrofitted.

<br>Note that bleed is a phenomenon associated with the nozzle flapper, which is separate from the relief action (action to depressurize when the set pressure rises too much). <br><br>Note 1) Be sure to use a mist separator in addition to the filters on the inlet side of IR1000/2000/3000 series regulators.

<br>For the IR400-02/03/04□□: IR3000-02/03/04□□-A<br>For the IR401-02/03/04□□: IR3010-02/03/04□□-A<br>For the IR402-02/03/04□□: IR3020-02/03/04□□-A<br>For the IR412-02/03/04□□: IR3120-02/03/04□□ (IR-A series air operated regulators will be available at a later date.) <br>Note) Select option “H” when panel mounting the product.

<br>Note 1) The element of the old AF and AW series (4 digits: AF□□□□), which were released in 1985, was initially a bronze element and then became a nonwoven fabric element later on. <br>Products with the bronze element need to be replaced with the current product.

<br>The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type). <br>For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.” <br>Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=combination-units&fa_id=10974

<br>④ The pipe length from the strainer to the liquid collector body is 20 m or more when the mounting height of the liquid collector is 3 m or more for a water-soluble solution or 1 m or more for an insoluble solution. <br>⑤ The dynamic viscosity of the fluid is too high to flow. <br>⑥ The operating fluid is air. (Air cannot be used as the fluid.

<br>Classification of a Class 2 pressure vessels is as follows.<br>① The internal capacity exceeds 40 L.<br>② The internal size exceeds 200 mm and the length exceeds 1000 mm.<br>③ The container holds gas with an operating pressure of 0.2 MPa or more.<br><br>Ref.) The capacity of the VBAT series air tank does not exceed 40 L.

<br>Note) The KK□ series S coupler cannot be used as a stop valve that requires zero leakage. Due to the specifications of the product, a certain amount of leakage is unavoidable.<br><br>