F02 C01 A2 B2 2 49.6 (N02: 50.1) M5 x 0.8 thread depth 5 30 26.2 20 8.45 20 30 Width across flats 17 10 2 x M3 x 0.5 thread depth 4 Piping port 02: R1/4 N02: NPT1/4 3.5 8.8 Atmospheric vent port 2.6 14.7 25.1 46.2 2 12.4 26.2 10.1 8.45 22 14.5 Piping port Rc1/8 Piping port G1/4 -F02: G1/4 -C01: Rc1/8 27.7 21.7 8.45 8.45 Piping port TSJ1/4 Piping port URJ1/4 -B2: TSJ1/4 -A2: URJ1/4 736 Series

P Q R S 4 4 20.6 15.6 10.4 6 6 21.6 16.6 12.8 F L AT T Y P E F L AT W I T H R I B Y Model A B C D E F G H I Flat Flat with Rib ZPR20 20 23 14 29 39.8 57.6 68.6 91.5 102.6 4 1.7 ZPR25 25 28 14 29 39.8 57.6 68.6 91.5 102.6 4 1.8 ZPR32 32 35 14.5 29.5 40.3 58.1 69.1 92 103.1 4.5 23 D E E P T Y P E Model A B C D E F G H I Y ZPR25D 25 28 20 35 45.8 63.6 74.6 97.6 108.6 10 A P P L I C A B L E T

24 V: 600 Min. load impedance 50 -S/-R (Auto-shift input mode) With auto-shift switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less -X (Copy function switch output) -S/-R (Copy input mode) NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less -22No.PS-OMU0009-D -V/-T (Analog output mode) Switch output PNP open

LEKFS series slider type / Common precautions . 24 5.1 Design / selection . 24 5.2 Handling . 24 5.3 Mounting . 25 5.4 Precaution on maintenance . 26 3.5 How to detach and attach the dust seal band . 27 5.7 Replacement of belt . 28 6.Troubleshooting . 29 6.1 Alarms . 29 -1- LEKFS Series / Electric Actuator Safety Instructions These safety instructions are intended to prevent hazardous situations

KJH 06 C2 Port size 06 6 One-touch fitting (Straight) Metric size 07 1/4 One-touch fitting (Straight) Inch size -33No. ZK2-OM01301 (8) Sound absorbing material (10 pcs. per set) ZK2-SE1-1-A Sound absorbing material hole diameter 1 300m (9) Vacuum port adapter assembly (Purchasing order is available in units of 1 piece.)

No. 1 2 3 4 5 6 7 8 9 10 L Dimension 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 No. 11 12 13 14 15 16 17 18 19 20 L Dimension 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 L Dimension 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 No. 31 32 33 34 35 36 37 38 39 40 L Dimension 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 -39No.

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

to 20 mA) output type PFM7--DMax. 28 V, 80 mA Internal voltage drop: 1 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 NPN (1 output) + External input type PFM7--GMax. 28 V, 80 mA Internal voltage drop: 1 V or less External input: No voltage input (reed switch or solid state), 30 ms or more -18No.PF-OMJ0006

(Refer to page 28.) (Refer to page 30.) : The outputs will continue to operate during setting. : If a button operation is not performed for 3 seconds during the setting, the display will flash.

Auto Switch Specifications PLC: Programmable Logic Controller Auto switch model Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Response time D-Y7BW(V)L-900 24 VDC relay, PLC 10 VDC to 28 VDC 2.5 mA to 40 mA 4 V or less 0.8 mA or less 1 ms or less Operating positionRed light is ON.

NOTES: r Split ranging allows position control using 3 to I psi or 9 to 15 psi as signal pressure Within 0.5% for each 7.5 osi Within 1% for each 1.5 psi Within 0.5% for each 1.5 psi Within 0.5% for each 1.5 psi Within 0.3% for each 1.5 psi " For 1/2 split range add 1.5% to these values Use clean, dry, oil free air Recommended for air preparation: NAC 2030-N02 or NAC 2040-N02 filter, coalescer

NOTES: r Split ranging allows position control using 3 to I psi or 9 to 15 psi as signal pressure Within 0.5% for each 7.5 osi Within 1% for each 1.5 psi Within 0.5% for each 1.5 psi Within 0.5% for each 1.5 psi Within 0.3% for each 1.5 psi " For 1/2 split range add 1.5% to these values Use clean, dry, oil free air Recommended for air preparation: NAC 2030-N02 or NAC 2040-N02 filter, coalescer

No.PS-OMV0008CN-E / / ISE70G--L2 ISE75G--L2 ISE76G--L2 ISE77G--L2 ISE78G--L2 2 9 10 12 15 15 17 19 21 22 3 23 25 27 27 28 F0 30 F1 OUT1 32 F2 OUT2 35 F3 37 F4 38 F6 40 F10 41 F11 47 F14 Zero-cut 48 F80 49 F81 50 F90 52 F96 54 F98 55 F99 57 58 IO-Link 63 IO-Link 63 63 64 IO-Link 67 76 76 77 86 88 -1No.PS-OMV0008CN-E (ISO/IEC)(JIS) *1) *2) *1) ISO

Split ranqinq allows position control using 3 to I psi or I lo 15 psi as signal pressure Within 0,5% for each 1 .5 osi Within 1% for each 1.5 DSi Within 0.5% for each 1.5 psi Within 0.3% for each 1.5 psi Within 0.5% for each 7.5 osi *Fof 1/2 split range add 1.5% to these values Use clean, dry, oil free air Recommended for air preparation: NAC 2030"N02 or NAC 2040-N02 filter, coalescer, regulator

LVD PAX1000, PA3000, PA5000 LVQ Proper tightening torque (Nm) Connection threads Rc 1/4 12 to 14 LQ Rc 3/8 22 to 24 LVN Rc 1/2 28 to 30 Rc 3/4 28 to 30 TI/ TIL 3. Ensure space for maintenance. When installing and mounting, be sure to allow the space required for maintenance and inspections. Confirm the necessary maintenance space in the instruction manual for each piece of equipment.